Optimizing photon counting CT enterography: determining the optimal virtual monoenergy for bowel imaging

被引:0
|
作者
Sharifi, Arghavan [1 ]
O'Donnell, Thomas [2 ]
Dane, Bari [1 ]
机构
[1] New York Univ, Langone Med Ctr, New York, NY 10016 USA
[2] Siemens Healthineers, Malvern, PA USA
关键词
Photon counting CT; CT enterography; Virtual monoenergetic reconstructions; Photon counting CT enterography; DUAL-ENERGY CT;
D O I
10.1007/s00261-025-04832-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To determine the optimal virtual monoenergy for viewing the bowel at photon-counting CT enterography using quantitative assessment of mural attenuation, contrast-to-noise ratio, signal-to-noise ratio and noise. Methods This study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. Consecutive adults (>= 18 years) who underwent photon-counting CT enterography from 5/1/2022-5/31/2022 with available Spectral Postprocessing (SPP) images for retrospective virtual monoenergy creation were identified. Nine virtual monoenergetic series (40-120 keV, 10 keV increments) were created. Two region-of-interest measurements were placed in the stomach wall, jejunum wall, ileum wall, and each psoas muscle by two radiologists on 0.6 mm images in PACS. Region-of-interests were copied to other virtual monoenergies to ensure identical placement and size. Attenuation (HU) and noise (HU standard deviation) were recorded from each region-of-interest. Signal-to-noise ratio and contrast-to-noise ratio were computed for stomach, jejunum, ileum, and all bowel combined. Pairwise comparisons for attenuation, noise, signal-to-noise ratio and contrast-to-noise ratio for each virtual monoenergy were performed with ANOVA. A p <.05 indicated statistical significance. Results 50 patients (32 female; mean[SD] age: 57 years) were included. Attenuation and noise for all bowel regions were highest at 40 keV with statistically significant pairwise comparisons from 40 to 70 keV (all p <.05), but similar for 70-120 keV (all p >.05). Signal-to-noise ratio was similar from 40 to 70 keV (all p >.05) for all bowel regions. Contrast-to-noise ratio decreased with increasing keV. Contrast-to-noise ratio was similar for all bowel at 40 keV and 50 keV (p =.06), for stomach from 40 to 70 keV (all p >.05), for jejunum from 40 to 50 keV (p =.21), and for ileum from 40 to 60 keV (all p >.05). Conclusion 50 keV virtual monoenergetic images from photon-counting CT enterography optimizes contrast-to-noise ratio while mitigating noise and should routinely be utilized for bowel assessment at photon-counting CT enterography. As most photon-counting CT users primarily interpret virtual monoenergetic images in clinical practice, knowledge of the optimal virtual monoenergy can inform protocol development.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Spectral photon-counting CT in cardiovascular imaging
    Sandfort, Veit
    Persson, Mats
    Pourmorteza, Amir
    Noel, Peter B.
    Fleischmann, Dominik
    Willemink, Martin J.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2021, 15 (03) : 218 - 225
  • [22] Photon-Counting CT: Virtual Study, Real Benefit
    Menu, Yves
    RADIOLOGY, 2025, 314 (01)
  • [23] Photon Counting Micro-CT for Imaging Cisplatin
    Badea, C. T.
    Clark, D. P.
    Alphin, A.
    Ghaghada, K. B.
    Mowery, Y. M.
    MEDICAL IMAGING 2022: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2022, 12036
  • [24] Soft tissue imaging with photon counting spectroscopic CT
    Shikhaliev, Polad M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (06): : 2453 - 2474
  • [25] Optimal Conspicuity of Liver Metastases in Virtual Monochromatic Imaging Reconstructions on a Novel Photon-Counting Detector CT Effect of keV Settings and BMI
    Bette, Stefanie
    Decker, Josua A.
    Braun, Franziska M.
    Becker, Judith
    Haerting, Mark
    Haeckel, Thomas
    Gebhard, Michael
    Risch, Franka
    Woznicki, Piotr
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    DIAGNOSTICS, 2022, 12 (05)
  • [26] CT enterography for Crohn's disease: optimal technique and imaging issues
    Baker, Mark E.
    Hara, Amy K.
    Platt, Joel F.
    Maglinte, Dean D. T.
    Fletcher, Joel G.
    ABDOMINAL IMAGING, 2015, 40 (05): : 938 - 952
  • [27] Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification
    Vrbaski, Stevan
    Bache, Steve
    Rajagopal, Jayasai
    Samei, Ehsan
    MEDICAL PHYSICS, 2023, 50 (09) : 5421 - 5433
  • [28] CT enterography for Crohn’s disease: optimal technique and imaging issues
    Mark E. Baker
    Amy K. Hara
    Joel F. Platt
    Dean D. T. Maglinte
    Joel G. Fletcher
    Abdominal Imaging, 2015, 40 : 938 - 952
  • [29] Edge-On Silicon Photon-Counting CT: Assessment of Diagnostic Value in a Virtual Imaging Trial
    Panta, R.
    Bhattarai, M.
    Yin, Z.
    Abadi, E.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2022, 49 (06) : E591 - E592
  • [30] A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT
    Sharma, Shobhit
    Vrbaski, Stevan
    Bhattarai, Mridul
    Abadi, Ehsan
    Longo, Renata
    Samei, Ehsan
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (22):