Photon Counting Micro-CT for Imaging Cisplatin

被引:0
|
作者
Badea, C. T. [1 ]
Clark, D. P. [1 ]
Alphin, A. [1 ]
Ghaghada, K. B. [2 ]
Mowery, Y. M. [3 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Quantitat Imaging & Anal Lab, Durham, NC 27710 USA
[2] Texas Childrens Hosp, Singleton Dept Radiol, Baylor Coll Med, Houston, TX 77030 USA
[3] Duke Univ, Dept Radiat Oncol, Med Ctr, Durham, NC 27710 USA
关键词
x-ray CT (CT); small animal imaging (SMAX); chemotherapy; photon counting; LIPOPLATIN;
D O I
10.1117/12.2612574
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The photon-counting (PC) detector technology promises to enhance the number of CT applications due to the spectral information. Of high interest for the cancer research community is imaging the tumor delivery of Cisplatin (CisPt), a chemotherapeutic agent utilized for treatment of numerous malignancies. CisPt contains platinum (Pt), a high-Z element material with a K-edge (78.4 keV) in the diagnostic spectrum. Our group has developed a preclinical prototype photon counting (PC) CT and applied it in cancer studies using nanoparticles. This study aims to investigate if CisPt can be imaged by K-edge spectral PCCT. Simulations and phantom experiments were performed to investigate CisPt detection using PCCT. We have selected scanning parameters (125 kVp) and energy thresholds (28, 34, 70, 78 keV) to enable K-edge separation of Pt and iodine (I) from calcium (Ca). The simulations include modeling of the polychromatic spectrum, and the PC detector response with spectral distortions. Two digital phantoms were used with maximum concentrations corresponding to low (2 mg/mL) and high (10 mg/mL) concentrations of I and Pt. A physical phantom with CisPt, I and Ca solutions was imaged both on our PC micro-CT and a novel clinical PCCT system. Material decompositions confirm the separation of Pt, Ca and I. However, low concentrations (<1 mg/mL) of CisPt are unlikely to be separated. Nevertheless, a liposomal nanoparticle-based CisPt formulation can enhance tumor delivery, via enhanced permeability and retention (EPR) and benefit from PCCT monitoring. Thus, depending on the levels of tumor accumulation, PCCT imaging of nanoparticles containing CisPt may become possible.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Simulation of PIXSCAN, a photon counting micro-CT for small animal imaging
    Brunner, F. Cassol
    Khoury, R.
    Benoit, D.
    Meessen, C.
    Bonissent, A.
    Morel, C.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [2] Hybrid Energy Integrating and Photon Counting Micro-CT
    Holbrook, M. D.
    Clark, D. P.
    Badea, C. T.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [3] Estimating optical parameters of biological tissues with photon-counting micro-CT
    Cong, Wenxiang
    Li, Mengzhou
    Guo, Xiaodong
    Wang, Ge
    Journal of the Optical Society of America A: Optics and Image Science, and Vision, 2022, 39 (05): : 841 - 846
  • [4] Estimating optical parameters of biological tissues with photon-counting micro-CT
    Cong, Wenxiang
    Li, Mengzhou
    Guo, Xiaodong
    Wang, Ge
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2022, 39 (05) : 841 - 846
  • [5] Micro-CT imaging of multiple K-edge elements using GaAs and CdTe photon counting detectors
    Allphin, A. J.
    Clark, D. P.
    Thuering, T.
    Bhandari, P.
    Ghaghada, K. B.
    Badea, C. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (08):
  • [6] Contrast-enhanced photon-counting micro-CT of tumor xenograft models
    Li, Mengzhou
    Guo, Xiaodong
    Verma, Amit
    Rudkouskaya, Alena
    Mckenna, Antigone M.
    Intes, Xavier
    Wang, Ge
    Barroso, Margarida
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (15):
  • [7] Characterization of the imaging performance of a micro-CT system based on the photon counting XPAD3/Si hybrid pixel
    Cassol, F.
    Dupont, M.
    Kronland-Martinet, C.
    Ouamara, H.
    Dawiec, A.
    Boursier, Y.
    Bonissent, A.
    Clemens, J-C
    Portal, L.
    Debarbieux, F.
    Morel, C.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2016, 2 (02):
  • [8] Development of a spectral, photon-counting micro-CT system with a translate-rotate geometry
    Holbrook, M.
    Clark, D. P.
    Barber, W.
    Badea, C. T.
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [9] A Deep Learning Approach for Rapid and Generalizable Denoising of Photon-Counting Micro-CT Images
    Nadkarni, Rohan
    Clark, Darin P.
    Allphin, Alex J.
    Badea, Cristian T.
    TOMOGRAPHY, 2023, 9 (04) : 1286 - 1302
  • [10] Comparison of a photon-counting-detector and a CMOS flat-panel-detector for a micro-CT
    Kim, J.
    Park, S.
    Hegazy, M.
    Lee, S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,