Photon Counting Micro-CT for Imaging Cisplatin

被引:0
|
作者
Badea, C. T. [1 ]
Clark, D. P. [1 ]
Alphin, A. [1 ]
Ghaghada, K. B. [2 ]
Mowery, Y. M. [3 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Quantitat Imaging & Anal Lab, Durham, NC 27710 USA
[2] Texas Childrens Hosp, Singleton Dept Radiol, Baylor Coll Med, Houston, TX 77030 USA
[3] Duke Univ, Dept Radiat Oncol, Med Ctr, Durham, NC 27710 USA
关键词
x-ray CT (CT); small animal imaging (SMAX); chemotherapy; photon counting; LIPOPLATIN;
D O I
10.1117/12.2612574
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The photon-counting (PC) detector technology promises to enhance the number of CT applications due to the spectral information. Of high interest for the cancer research community is imaging the tumor delivery of Cisplatin (CisPt), a chemotherapeutic agent utilized for treatment of numerous malignancies. CisPt contains platinum (Pt), a high-Z element material with a K-edge (78.4 keV) in the diagnostic spectrum. Our group has developed a preclinical prototype photon counting (PC) CT and applied it in cancer studies using nanoparticles. This study aims to investigate if CisPt can be imaged by K-edge spectral PCCT. Simulations and phantom experiments were performed to investigate CisPt detection using PCCT. We have selected scanning parameters (125 kVp) and energy thresholds (28, 34, 70, 78 keV) to enable K-edge separation of Pt and iodine (I) from calcium (Ca). The simulations include modeling of the polychromatic spectrum, and the PC detector response with spectral distortions. Two digital phantoms were used with maximum concentrations corresponding to low (2 mg/mL) and high (10 mg/mL) concentrations of I and Pt. A physical phantom with CisPt, I and Ca solutions was imaged both on our PC micro-CT and a novel clinical PCCT system. Material decompositions confirm the separation of Pt, Ca and I. However, low concentrations (<1 mg/mL) of CisPt are unlikely to be separated. Nevertheless, a liposomal nanoparticle-based CisPt formulation can enhance tumor delivery, via enhanced permeability and retention (EPR) and benefit from PCCT monitoring. Thus, depending on the levels of tumor accumulation, PCCT imaging of nanoparticles containing CisPt may become possible.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System
    Podgorsak, A.
    Bednarek, D.
    Rudin, S.
    Ionita, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3901 - 3901
  • [42] High resolution micro-CT of low attenuating organic materials using large area photon-counting detector
    Kumpova, I.
    Vavrik, D.
    Fila, T.
    Koudelka, P.
    Jandejsek, I.
    Jakubek, J.
    Kytyr, D.
    Zlamal, P.
    Vopalensky, M.
    Gantar, A.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [43] Development of a Monte Carlo simulation platform for the systematic evaluation of photon-counting detector-based micro-CT
    Yang, Shiyan
    Xue, Mengjia
    Xie, Tianwu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 126
  • [44] Multi bin energy-sensitive micro-CT using large area photon-counting detectors Timepix
    Dudak, J.
    Zemlicka, J.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01):
  • [45] Micro-CT Imaging and Mechanical Properties of Ovine Ribs
    Thomas, Patricia K.
    Caffrey, Juliette
    Afetse, K. Eddie
    Habet, Nahir A.
    Ondar, Kyle
    Weaver, Caitlin M.
    Kleinberger, Michael
    Brown, Philip
    Gayzik, F. Scott
    ANNALS OF BIOMEDICAL ENGINEERING, 2023, 51 (07) : 1513 - 1522
  • [46] The role of micro-CT in imaging breast cancer specimens
    Tiwari, Ankur
    DiCorpo, Daniel
    Hughes, Kevin
    Michaelson, James
    CANCER RESEARCH, 2020, 80 (04)
  • [47] The role of Micro-CT in imaging breast cancer specimens
    Daniel DiCorpo
    Ankur Tiwari
    Rong Tang
    Molly Griffin
    Owen Aftreth
    Pinky Bautista
    Kevin Hughes
    Neil Gershenfeld
    James Michaelson
    Breast Cancer Research and Treatment, 2020, 180 : 343 - 357
  • [48] Mobile benchtop in-vivo micro-CT imaging
    Vandeghinste, Bert
    Van Holen, Roel
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [49] Imaging of Mouse Brain Fixated in Ethanol in Micro-CT
    Mrzilkova, Jana
    Patzelt, Matej
    Gallina, Pasquale
    Wurst, Zdenek
    Seremeta, Martin
    Dudak, Jan
    Krejci, Frantisek
    Zemlicka, Jan
    Musil, Vladimir
    Karch, Jakub
    Rosina, Jozef
    Zach, Petr
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [50] SPECT/micro-CT imaging of bronchial angiogenesis in a rat
    Clough, AV
    Wietholt, C
    Molthen, RC
    Gordon, JC
    Roerig, DL
    Small Animal SPECT Imaging, 2005, : 273 - 277