Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification

被引:8
|
作者
Vrbaski, Stevan [1 ,2 ,3 ]
Bache, Steve [2 ]
Rajagopal, Jayasai [1 ,4 ]
Samei, Ehsan [1 ,5 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Univ Trieste, Dept Phys, Trieste, Italy
[3] Elettra Sincrotrone Trieste, Trieste, Italy
[4] NIH, Radiol & Imaging Sci, Clin Ctr, Bethesda, MD USA
[5] Duke Univ, Med Ctr, Dept Radiol, Clin Imaging Phys Grp, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
iodine quantification; photon-counting CT; virtual monochromatic imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ITERATIVE-RECONSTRUCTION; ACCURACY; ATTENUATION; IMAGES;
D O I
10.1002/mp.16583
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantitative imaging techniques, such as virtual monochromatic imaging (VMI) and iodine quantification (IQ), have proven valuable diagnostic methods in several specific clinical tasks such as tumor and tissue differentiation. Recently, a new generation of computed tomography (CT) scanners equipped with photon-counting detectors (PCD) has reached clinical status. PurposeThis work aimed to investigate the performance of a new photon-counting CT (PC-CT) in low-dose quantitative imaging tasks, comparing it to an earlier generation CT scanner with an energy-integrating detector dual-energy CT (DE-CT). The accuracy and precision of the quantification across size, dose, material types (including low and high iodine concentrations), displacement from iso-center, and solvent (tissue background) composition were explored. MethodsQuantitative analysis was performed on two clinical scanners, Siemens SOMATOM Force and NAEOTOM Alpha using a multi-energy phantom with plastic inserts mimicking different iodine concentrations and tissue types. The tube configurations in the dual-energy scanner were 80/150Sn kVp and 100/150Sn kVp, while for PC-CT both tube voltages were set to either 120 or 140 kVp with photon-counting energy thresholds set at 20/65 or 20/70 keV. The statistical significance of patient-related parameters in quantitative measurements was examined using ANOVA and pairwise comparison with the posthoc Tukey honest significance test. Scanner bias was assessed in both quantitative tasks for relevant patient-specific parameters. ResultsThe accuracy of IQ and VMI in the PC-CT was comparable between standard and low radiation doses (p < 0.01). The patient size and tissue type significantly affect the accuracy of both quantitative imaging tasks in both scanners. The PC-CT scanner outperforms the DE-CT scanner in the IQ task in all cases. Iodine quantification bias in the PC-CT (-0.9 & PLUSMN; 0.15 mg/mL) at low doses in our study was comparable to that of DE-CT (range -2.6 to 1.5 mg/mL, published elsewhere) at a 1.7x higher dose, but the dose reduction severely biased DE-CT (4.72 & PLUSMN; 0.22 mg/mL). The accuracy in Hounsfield units (HU) estimation was comparable for 70 and 100 keV virtual imaging between scanners, but PC-CT was significantly underestimating virtual 40 keV HU values of dense materials in the phantom representing the extremely obese population. ConclusionsThe statistical analysis of our measurements reveals better IQ at lower radiation doses using new PC-CT. Although VMI performance was mostly comparable between the scanners, the DE-CT scanner quantitatively outperformed PC-CT when estimating HU values in the specific case of very large phantoms and dense materials, benefiting from increased X-ray tube potentials.
引用
收藏
页码:5421 / 5433
页数:13
相关论文
共 50 条
  • [1] DOSE REDUCTION IN QUANTITATIVE IODINE IMAGING WITH PHOTON-COUNTING CT
    Rodesch, Pierre-Antoine
    Richtsmeier, Devon
    Bazalova-Carter, Magdalena
    [J]. RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S104 - S105
  • [2] Development of virtual monochromatic imaging technique with spectral CT based on a photon-counting detector
    Lee, Seungwan
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Duhgoon
    Lee, Chang-Lae
    Jung, Jinwook
    Jang, Wooyoung
    Choi, Yuna
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [3] Simultaneous iodine and barium imaging with photon-counting CT
    Deng, Xinchen
    Richtsmeier, Devon
    Rodesch, Pierre-Antoine
    Iniewski, Kris
    Bazalova-Carter, Magdalena
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (19):
  • [4] Quantitative imaging performance of MARS spectral photon-counting CT for radiotherapy
    Simard, Mikael
    Panta, Raj Kumar
    Bell, Stephen T.
    Butler, Anthony P. H.
    Bouchard, Hugo
    [J]. MEDICAL PHYSICS, 2020, 47 (08) : 3423 - 3434
  • [5] Quantitative imaging performance of MARS spectral photon-counting CT for radiotherapy
    Simard, M.
    Panta, R. Kumar
    Prebble, H.
    Butler, A. P. H.
    Butler, P. H.
    Bouchard, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S328 - S329
  • [6] Comparison of Low Dose Performance of Photon-Counting and Energy Integrating CT
    Rajagopal, Jayasai R.
    Farhadi, Faraz
    Solomon, Justin
    Sahbaee, Pooyan
    Saboury, Babak
    Pritchard, William F.
    Jones, Elizabeth C.
    Samei, Ehsan
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (12) : 1754 - 1760
  • [7] Photon-counting CT: Scouting for Quantitative Imaging Biomarkers
    Pourmorteza, Amir
    [J]. RADIOLOGY, 2021, 298 (01) : 153 - 154
  • [8] Standardization and Quantitative Imaging With Photon-Counting Detector CT
    McCollough, Cynthia H.
    Rajendran, Kishore
    Leng, Shuai
    [J]. INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 451 - 458
  • [9] Spectral Imaging in Photon-Counting CT: Virtual Monochromatic Analysis Vs. Principal Component Analysis
    Tang, X.
    Ren, Y.
    Xie, H.
    Long, W.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E553 - E553
  • [10] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    [J]. CLINICAL IMAGING, 2023, 102 : 109 - 115