Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification

被引:15
|
作者
Vrbaski, Stevan [1 ,2 ,3 ]
Bache, Steve [2 ]
Rajagopal, Jayasai [1 ,4 ]
Samei, Ehsan [1 ,5 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Univ Trieste, Dept Phys, Trieste, Italy
[3] Elettra Sincrotrone Trieste, Trieste, Italy
[4] NIH, Radiol & Imaging Sci, Clin Ctr, Bethesda, MD USA
[5] Duke Univ, Med Ctr, Dept Radiol, Clin Imaging Phys Grp, Durham, NC 27705 USA
基金
美国国家卫生研究院;
关键词
iodine quantification; photon-counting CT; virtual monochromatic imaging; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ITERATIVE-RECONSTRUCTION; ACCURACY; ATTENUATION; IMAGES;
D O I
10.1002/mp.16583
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantitative imaging techniques, such as virtual monochromatic imaging (VMI) and iodine quantification (IQ), have proven valuable diagnostic methods in several specific clinical tasks such as tumor and tissue differentiation. Recently, a new generation of computed tomography (CT) scanners equipped with photon-counting detectors (PCD) has reached clinical status. PurposeThis work aimed to investigate the performance of a new photon-counting CT (PC-CT) in low-dose quantitative imaging tasks, comparing it to an earlier generation CT scanner with an energy-integrating detector dual-energy CT (DE-CT). The accuracy and precision of the quantification across size, dose, material types (including low and high iodine concentrations), displacement from iso-center, and solvent (tissue background) composition were explored. MethodsQuantitative analysis was performed on two clinical scanners, Siemens SOMATOM Force and NAEOTOM Alpha using a multi-energy phantom with plastic inserts mimicking different iodine concentrations and tissue types. The tube configurations in the dual-energy scanner were 80/150Sn kVp and 100/150Sn kVp, while for PC-CT both tube voltages were set to either 120 or 140 kVp with photon-counting energy thresholds set at 20/65 or 20/70 keV. The statistical significance of patient-related parameters in quantitative measurements was examined using ANOVA and pairwise comparison with the posthoc Tukey honest significance test. Scanner bias was assessed in both quantitative tasks for relevant patient-specific parameters. ResultsThe accuracy of IQ and VMI in the PC-CT was comparable between standard and low radiation doses (p < 0.01). The patient size and tissue type significantly affect the accuracy of both quantitative imaging tasks in both scanners. The PC-CT scanner outperforms the DE-CT scanner in the IQ task in all cases. Iodine quantification bias in the PC-CT (-0.9 & PLUSMN; 0.15 mg/mL) at low doses in our study was comparable to that of DE-CT (range -2.6 to 1.5 mg/mL, published elsewhere) at a 1.7x higher dose, but the dose reduction severely biased DE-CT (4.72 & PLUSMN; 0.22 mg/mL). The accuracy in Hounsfield units (HU) estimation was comparable for 70 and 100 keV virtual imaging between scanners, but PC-CT was significantly underestimating virtual 40 keV HU values of dense materials in the phantom representing the extremely obese population. ConclusionsThe statistical analysis of our measurements reveals better IQ at lower radiation doses using new PC-CT. Although VMI performance was mostly comparable between the scanners, the DE-CT scanner quantitatively outperformed PC-CT when estimating HU values in the specific case of very large phantoms and dense materials, benefiting from increased X-ray tube potentials.
引用
收藏
页码:5421 / 5433
页数:13
相关论文
共 50 条
  • [31] Performance Characteristics of Photon-Counting Breast CT
    Kalender, W.
    MEDICAL PHYSICS, 2016, 43 (06) : 3829 - 3830
  • [32] Optimal Conspicuity of Liver Metastases in Virtual Monochromatic Imaging Reconstructions on a Novel Photon-Counting Detector CT Effect of keV Settings and BMI
    Bette, Stefanie
    Decker, Josua A.
    Braun, Franziska M.
    Becker, Judith
    Haerting, Mark
    Haeckel, Thomas
    Gebhard, Michael
    Risch, Franka
    Woznicki, Piotr
    Scheurig-Muenkler, Christian
    Kroencke, Thomas J.
    Schwarz, Florian
    DIAGNOSTICS, 2022, 12 (05)
  • [33] Accuracy Assessment of Photon-Counting CT for Dose Calculation in Photon Therapy
    Wu, X.
    Shah, J.
    Wohlfahrt, P.
    Wu, Q.
    Wu, Q. J.
    Sheng, Y.
    MEDICAL PHYSICS, 2024, 51 (10) : 7669 - 7669
  • [34] Impact of CT Photon-Counting Virtual Monoenergetic Imaging on Visualization of Abdominal Arterial Vessels
    Dillinger, Daniel
    Overhoff, Daniel
    Booz, Christian
    Kaatsch, Hanns L.
    Piechotka, Joel
    Hagen, Achim
    Froelich, Matthias F.
    Vogl, Thomas J.
    Waldeck, Stephan
    DIAGNOSTICS, 2023, 13 (05)
  • [35] Low dose and high image quality tomosynthesis with a photon-counting imaging technology
    Francke, T
    Maidment, A
    Thunberg, S
    Adelow, L
    Blom, O
    Egerstrom, J
    Eklund, M
    Jordung, U
    Kristoffersson, T
    Lidman, K
    Lindqvist, L
    Marchal, D
    Olla, H
    Penton, E
    Ratanen, J
    Sokolov, S
    Ullberg, C
    Weber, N
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (04) : 42 - 42
  • [36] Advantages of Photon-Counting Detector CT in Aortic Imaging
    Zanon, Chiara
    Cademartiri, Filippo
    Toniolo, Alessandro
    Bini, Costanza
    Clemente, Alberto
    Colacchio, Elda Chiara
    Cabrelle, Giulio
    Mastro, Florinda
    Antonello, Michele
    Quaia, Emilio
    Pepe, Alessia
    TOMOGRAPHY, 2024, 10 (01) : 1 - 13
  • [37] First human imaging with MARS photon-counting CT
    Panta, Raj Kumar
    Butler, Anthony P. H.
    Butler, Philip H.
    de Ruiter, Niels J. A.
    Bell, Stephen T.
    Walsh, Michael F.
    Doesburg, Robert M. N.
    Chernoglazov, Alexander, I
    Goulter, Brian P.
    Carbonez, Pierre
    Damet, Jerome
    Adebileje, Sikiru A.
    Alexander, Steven D.
    Amma, Maya R.
    Anjomrouz, Marzieh
    Asghariomabad, Fatemeh
    Atharifard, Ali
    Baer, Kenzie
    Bamford, Benjamin
    Bheesette, Srinidhi
    Chambers, Claire
    Dahal, Shishir
    Dalefield, Tara
    Duncan, Neryda
    Gieseg, Steven P.
    Gurney, Sam
    Healy, Joseph L.
    Hilton, Peter J.
    Kanithi, Preveenkumar
    Kirkbride, Tracy
    Lansley, Stuart P.
    Lowe, Chiara
    Mandalika, V. B. H.
    Marfo, Emmanuel
    Matanaghi, Aysouda
    Moghiseh, Mandieh
    Palmer, David
    Prebble, Hannah M.
    Raja, Aamir Y.
    Ramyar, Mohsen
    Renaud, Peter
    Schleich, Nanette
    Searle, Emily
    Shamshad, Muhammad
    Sheeja, Jereena S.
    Uddin, Rayhan
    Vanden Broeke, Lieza
    Vivek, V. S.
    Walker, E. Peter
    Wijesooriya, Manoj
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [38] Exploiting the Potential of Photon-Counting CT in Abdominal Imaging
    Schwartz, Fides Regina
    Samei, Ehsan
    Marin, Daniele
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 488 - 498
  • [39] Photon-Counting CT Material Decomposition in Bone Imaging
    Bhattarai, Abhisek
    Tanaka, Ray
    Yeung, Andy Wai Kan
    Vardhanabhuti, Varut
    JOURNAL OF IMAGING, 2023, 9 (10)
  • [40] Chances and challenges of photon-counting CT in musculoskeletal imaging
    Mourad, Charbel
    Gallego Manzano, Lucia
    Viry, Anais
    Booij, Ronald
    Oei, Edwin H. G.
    Becce, Fabio
    Omoumi, Patrick
    SKELETAL RADIOLOGY, 2024, 53 (09) : 1889 - 1902