A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT

被引:0
|
作者
Sharma, Shobhit [1 ,2 ,7 ,10 ,12 ]
Vrbaski, Stevan [1 ,2 ,3 ,4 ,5 ]
Bhattarai, Mridul [1 ,2 ,7 ,8 ]
Abadi, Ehsan [1 ,2 ,7 ,8 ,9 ]
Longo, Renata [2 ,4 ,6 ]
Samei, Ehsan [1 ,2 ,7 ,8 ,9 ,10 ,11 ]
机构
[1] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ, Ctr Virtual Imaging Trials, Durham, NC 27705 USA
[3] Univ Novi Sad, Fac Med, Hajduk Veljkova 1-3, Novi Sad 21000, Serbia
[4] Univ Trieste, Dept Phys, Via Valerio 2, I-34127 Trieste, Italy
[5] Elettra Sincrotrone Trieste SCpA, I-34149 Basovizza, Italy
[6] INFN, Div Trieste, Via Valerio 2, I-34127 Trieste, Italy
[7] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27705 USA
[8] Duke Univ, Med Ctr, Med Phys Grad Program, Durham, NC 27705 USA
[9] Duke Univ, Dept Phys, Durham, NC 27705 USA
[10] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27705 USA
[11] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27705 USA
[12] Canon Med Res USA, 706N Deerpath Dr, Vernon Hills, IL 60061 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 22期
基金
美国国家卫生研究院;
关键词
photon-counting; computed tomography; charge sharing; pulse pileup; virtual imaging simulations; DETECTOR;
D O I
10.1088/1361-6560/ad8b0a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This study describes the development, validation, and integration of a detector response model that accounts for the combined effects of x-ray crosstalk, charge sharing, and pulse pileup in photon-counting detectors. Approach. The x-ray photon transport was simulated using Geant4, followed by analytical charge sharing simulation in MATLAB. The analytical simulation models charge clouds with Gaussian-distributed charge densities, which are projected on a 3x3 pixel neighborhood of interaction location to compute detected counts. For pulse pileup, a prior analytical method for redistribution of energy-binned counts was implemented for delta pulses. The x-ray photon transport and charge sharing components were validated using experimental data acquired on the CdTe-based Pixirad-1/Pixie-III detector using monoenergetic beams at 26, 33, 37, and 50 keV. The pulse pileup implementation was verified with a comparable Monte Carlo simulation. The model output without pulse pileup was used to generate spatio-energetic response matrices for efficient simulation of scanner-specific photon-counting CT (PCCT) images with DukeSim, with pulse pileup modeled as a post-processing step on simulated projections. For analysis, images for the Gammex multi-energy phantom and the XCAT chest phantom were simulated at 120 kV, both with and without pulse pileup for a range of doses (27-1344 mAs). The XCAT images were evaluated qualitatively at 120 mAs, while images for the Gammex phantom were evaluated quantitatively for all doses using measurements of attenuation coefficients and Calcium concentrations. Main results. Reasonable agreement was observed between simulated and experimental spectra with Mean Absolute Percentage Error Values (MAPE) between 10% and 31% across all incident energies and detector modes. The increased pulse pileup from increased dose affected attenuation coefficients and calcium concentrations, with an effect on calcium quantification as high as MAPE of 28%. Significance. The presented approach demonstrates the viability of the model for enabling VITs to assess and optimize the clinical performance of PCCT.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Simulation of the combined effects of charge sharing and pulse pileup in photon-counting CT
    Bhattarai, Mridul
    Sharma, Shobhit
    Vrbaski, Stevan
    Abadi, Ehsan
    Segars, W. Paul
    Contillo, Adriano
    Longo, Renata
    Samei, Ehsan
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [2] Model-Based Pulse Pileup and Charge Sharing Compensation for Photon Counting Detectors
    Taguchi, K.
    Polster, C.
    Segars, W.
    Aygun, N.
    Stierstorfer, K.
    MEDICAL PHYSICS, 2022, 49 (06) : E435 - E436
  • [3] Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT
    Abadi, Ehsan
    McCabe, Cindy
    Harrawood, Brian
    Sotoudeh-Paima, Saman
    Segars, W. Paul
    Samei, Ehsan
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [4] Model-based pulse pileup and charge sharing compensation for photon counting detectors: A simulation study
    Taguchi, Katsuyuki
    Polster, Christoph
    Segars, W. Paul
    Aygun, Nafi
    Stierstorfer, Karl
    MEDICAL PHYSICS, 2022, 49 (08) : 5038 - 5051
  • [5] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    CLINICAL IMAGING, 2023, 102 : 109 - 115
  • [6] Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT
    Mergen, Victor
    Racine, Damien
    Jungblut, Lisa
    Sartoretti, Thomas
    Bickel, Steven
    Monnin, Pascal
    Higashigaito, Kai
    Martini, Katharina
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 305 (01) : 106 - 114
  • [7] Experimental study of photon-counting CT neural network material decomposition under conditions of pulse pileup
    Jenkins, Parker J. B.
    Schmidt, Taly Gilat
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (01)
  • [8] Photon-counting CT in lung imaging
    Tarnoki, adam Domonkos
    Tarnoki, David Laszlo
    Maurovich-Horvat, Pal
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2025, 19 (02) : 77 - 81
  • [9] Photon-counting Detector CT: Initial Analysis of Virtual Noncontrast Imaging
    Sosna, Jacob
    RADIOLOGY, 2022, 305 (01) : 115 - 116
  • [10] Photon-counting CT to Virtual Noncontrast CT Images
    Pourmorteza, Amir
    RADIOLOGY, 2023, 306 (01) : 205 - 206