A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT

被引:0
|
作者
Sharma, Shobhit [1 ,2 ,7 ,10 ,12 ]
Vrbaski, Stevan [1 ,2 ,3 ,4 ,5 ]
Bhattarai, Mridul [1 ,2 ,7 ,8 ]
Abadi, Ehsan [1 ,2 ,7 ,8 ,9 ]
Longo, Renata [2 ,4 ,6 ]
Samei, Ehsan [1 ,2 ,7 ,8 ,9 ,10 ,11 ]
机构
[1] Duke Univ, Carl E Ravin Adv Imaging Labs, Durham, NC 27705 USA
[2] Duke Univ, Ctr Virtual Imaging Trials, Durham, NC 27705 USA
[3] Univ Novi Sad, Fac Med, Hajduk Veljkova 1-3, Novi Sad 21000, Serbia
[4] Univ Trieste, Dept Phys, Via Valerio 2, I-34127 Trieste, Italy
[5] Elettra Sincrotrone Trieste SCpA, I-34149 Basovizza, Italy
[6] INFN, Div Trieste, Via Valerio 2, I-34127 Trieste, Italy
[7] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27705 USA
[8] Duke Univ, Med Ctr, Med Phys Grad Program, Durham, NC 27705 USA
[9] Duke Univ, Dept Phys, Durham, NC 27705 USA
[10] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27705 USA
[11] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27705 USA
[12] Canon Med Res USA, 706N Deerpath Dr, Vernon Hills, IL 60061 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 22期
基金
美国国家卫生研究院;
关键词
photon-counting; computed tomography; charge sharing; pulse pileup; virtual imaging simulations; DETECTOR;
D O I
10.1088/1361-6560/ad8b0a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. This study describes the development, validation, and integration of a detector response model that accounts for the combined effects of x-ray crosstalk, charge sharing, and pulse pileup in photon-counting detectors. Approach. The x-ray photon transport was simulated using Geant4, followed by analytical charge sharing simulation in MATLAB. The analytical simulation models charge clouds with Gaussian-distributed charge densities, which are projected on a 3x3 pixel neighborhood of interaction location to compute detected counts. For pulse pileup, a prior analytical method for redistribution of energy-binned counts was implemented for delta pulses. The x-ray photon transport and charge sharing components were validated using experimental data acquired on the CdTe-based Pixirad-1/Pixie-III detector using monoenergetic beams at 26, 33, 37, and 50 keV. The pulse pileup implementation was verified with a comparable Monte Carlo simulation. The model output without pulse pileup was used to generate spatio-energetic response matrices for efficient simulation of scanner-specific photon-counting CT (PCCT) images with DukeSim, with pulse pileup modeled as a post-processing step on simulated projections. For analysis, images for the Gammex multi-energy phantom and the XCAT chest phantom were simulated at 120 kV, both with and without pulse pileup for a range of doses (27-1344 mAs). The XCAT images were evaluated qualitatively at 120 mAs, while images for the Gammex phantom were evaluated quantitatively for all doses using measurements of attenuation coefficients and Calcium concentrations. Main results. Reasonable agreement was observed between simulated and experimental spectra with Mean Absolute Percentage Error Values (MAPE) between 10% and 31% across all incident energies and detector modes. The increased pulse pileup from increased dose affected attenuation coefficients and calcium concentrations, with an effect on calcium quantification as high as MAPE of 28%. Significance. The presented approach demonstrates the viability of the model for enabling VITs to assess and optimize the clinical performance of PCCT.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Photon-counting detector CT for abdominal imaging: opportunities and challenges
    Schwartz, Fides Regina
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7805 - 7806
  • [42] Evaluation of a preclinical photon-counting CT prototype for pulmonary imaging
    Felix K. Kopp
    Heiner Daerr
    Salim Si-Mohamed
    Andreas P. Sauter
    Sebastian Ehn
    Alexander A. Fingerle
    Bernhard Brendel
    Franz Pfeiffer
    Ewald Roessl
    Ernst J. Rummeny
    Daniela Pfeiffer
    Roland Proksa
    Philippe Douek
    Peter B. Noël
    Scientific Reports, 8
  • [43] Investigation of the LabPET™ detector and electronics for photon-counting CT imaging
    Berard, Philippe
    Riendeau, Joel
    Pepin, Catherine M.
    Rouleau, Daniel
    Cadorette, Jules
    Fontaine, Rejean
    Lecomte, Roger
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 114 - 117
  • [44] Photon-counting detector CT: a disrupting innovation in medical imaging
    Akos Varga-Szemes
    Tilman Emrich
    European Radiology Experimental, 9 (1)
  • [45] Study on the impact of bowtie filter on photon-counting CT imaging
    Zhang, Xin
    Xie, Jixiong
    Su, Ting
    Zhu, Jiongtao
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (21):
  • [46] Photon-counting detector CT for abdominal imaging: opportunities and challenges
    Fides Regina Schwartz
    Hatem Alkadhi
    European Radiology, 2023, 33 : 7805 - 7806
  • [47] Multicolour imaging with spectral photon-counting CT: a phantom study
    Si-Mohamed S.
    Bar-Ness D.
    Sigovan M.
    Tatard-Leitman V.
    Cormode D.P.
    Naha P.C.
    Coulon P.
    Rascle L.
    Roessl E.
    Rokni M.
    Altman A.
    Yagil Y.
    Boussel L.
    Douek P.
    European Radiology Experimental, 2 (1)
  • [48] New Horizons in Vascular Imaging With Photon-Counting Detector CT
    Wildberger, Joachim E.
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 499 - 504
  • [49] DOSE REDUCTION IN QUANTITATIVE IODINE IMAGING WITH PHOTON-COUNTING CT
    Rodesch, Pierre-Antoine
    Richtsmeier, Devon
    Bazalova-Carter, Magdalena
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S104 - S105
  • [50] Optimizing Photon-Counting Detector CT for Imaging Intracranial Aneurysms
    Rajendran, Kishore
    Madhavan, Ajay A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (10) : 1458 - 1460