Development and Clinical Applications of a Virtual Imaging Framework for Optimizing Photon-counting CT

被引:11
|
作者
Abadi, Ehsan [1 ]
McCabe, Cindy [1 ]
Harrawood, Brian [1 ]
Sotoudeh-Paima, Saman [1 ]
Segars, W. Paul [1 ]
Samei, Ehsan [1 ]
机构
[1] Duke Univ, Ctr Virtual Imaging Trials, Carl E Ravin Adv Imaging Labs, Dept Radiol, Durham, NC 27706 USA
基金
美国国家卫生研究院;
关键词
Computed Tomography; CT simulator; Photon-counting CT; DukeSim; Virtual clinical trial; Virtual imaging trials; XCAT; CT Quantifications; COPD; Radiomics; PHANTOMS;
D O I
10.1117/12.2612079
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The purpose of this study was to develop a virtual imaging framework that simulates a new photon-counting CT (PCCT) system (NAEOTOM Alpha, Siemens). The PCCT simulator was built upon the DukeSim platform, which generates projection images of computational phantoms given the geometry and physics of the scanner and imaging parameters. DukeSim was adapted to account for the geometry of the PCCT prototype. To model the photon-counting detection process, we utilized a Monte Carlo-based detector model with the known properties of the detectors. We validated the simulation platform against experimental measurements. The images were acquired at four dose levels (CTDIvol of 1.5, 3.0, 6.0, and 12.0 mGy) and reconstructed with three kernels (Br36, Br40, Br48). The experimental acquisitions were replicated using our developed simulation platform. The real and simulated images were quantitatively compared in terms of image quality metrics (HU values, noise magnitude, noise power spectrum, and modulation transfer function). The clinical utility of our framework was demonstrated by conducting two clinical applications (COPD quantifications and lung nodule radiomics). The phantoms with relevant pathologies were imaged with DukeSim modeling the PCCT systems. Different imaging parameters (e.g., dose, reconstruction techniques, pixel size, and slice thickness) were altered to investigate their effects on task-based quantifications. We successfully implemented the acquisition and physics attributes of the PCCT prototype into the DukeSim platform. The discrepancy between the real and simulated data was on average about 2 HU in terms of noise magnitude, 0.002 mm(-1) in terms of noise power spectrum peak frequency and 0.005 mm(-1) in terms of the frequency at 50% MTF. Analysis suggested that lung lesion radiomics to be more accurate with reduced pixel size and slice thickness. For COPD quantifications, higher doses, thinner slices, and softer kernels yielded more accurate quantification of density-based biomarkers. Our developed virtual imaging platform enables systematic comparison of new PCCT technologies as well as optimization of the imaging parameters for specific clinical tasks.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Clinical CT Applications with Photon-Counting Detectors
    Levinson, R.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [2] Optimizing Photon-Counting Detector CT for Imaging Intracranial Aneurysms
    Rajendran, Kishore
    Madhavan, Ajay A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2024, 45 (10) : 1458 - 1460
  • [3] Virtual monoenergetic imaging in photon-counting CT of the head and neck
    Farhadi, Faraz
    Sahbaee, Pooyan
    Rajagopal, Jayasai R.
    Nikpanah, Moozhan
    Saboury, Babak
    Gutjahr, Ralf
    Biassou, Nadia M.
    Shah, Ritu
    Flohr, Thomas G.
    Samei, Ehsan
    Pritchard, William F.
    Malayeri, Ashkan A.
    Bluemke, David A.
    Jones, Elizabeth C.
    CLINICAL IMAGING, 2023, 102 : 109 - 115
  • [4] Virtual Noncontrast Abdominal Imaging with Photon-counting Detector CT
    Mergen, Victor
    Racine, Damien
    Jungblut, Lisa
    Sartoretti, Thomas
    Bickel, Steven
    Monnin, Pascal
    Higashigaito, Kai
    Martini, Katharina
    Alkadhi, Hatem
    Euler, Andre
    RADIOLOGY, 2022, 305 (01) : 106 - 114
  • [5] Development of virtual monochromatic imaging technique with spectral CT based on a photon-counting detector
    Lee, Seungwan
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Duhgoon
    Lee, Chang-Lae
    Jung, Jinwook
    Jang, Wooyoung
    Choi, Yuna
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [6] A framework to model charge sharing and pulse pileup for virtual imaging trials of photon-counting CT
    Sharma, Shobhit
    Vrbaski, Stevan
    Bhattarai, Mridul
    Abadi, Ehsan
    Longo, Renata
    Samei, Ehsan
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (22):
  • [7] Photon-counting CT in lung imaging
    Tarnoki, adam Domonkos
    Tarnoki, David Laszlo
    Maurovich-Horvat, Pal
    EXPERT REVIEW OF RESPIRATORY MEDICINE, 2025, 19 (02) : 77 - 81
  • [8] Abdominal applications of photon-counting CT
    Khanungwanitkul, Khanin
    Sliwicka, Olga
    Schwartz, Fides Regina
    BRITISH JOURNAL OF RADIOLOGY, 2024,
  • [9] Photon-counting Detector CT: Initial Analysis of Virtual Noncontrast Imaging
    Sosna, Jacob
    RADIOLOGY, 2022, 305 (01) : 115 - 116
  • [10] Photon-counting CT to Virtual Noncontrast CT Images
    Pourmorteza, Amir
    RADIOLOGY, 2023, 306 (01) : 205 - 206