Optimization of the design of a single-sided magnetic resonance magnet array for improved T2 estimation accuracy

被引:0
|
作者
Miao, Ruixin [1 ,2 ,3 ]
Ren, Chunpeng [1 ,2 ,3 ]
Jiang, Chuandong [1 ,2 ,3 ]
Wang, Qingyue [1 ,2 ,3 ]
Wang, Yunzhi [1 ,2 ,3 ]
Yu, Xiangqian [4 ]
机构
[1] Minist Educ China, Key Lab Geophys Explorat Equipment, Changchun 130061, Peoples R China
[2] Jilin Univ, Coll Instrumentat & Elect Engn, Changchun 130061, Peoples R China
[3] Natl Geophys Explorat Equipment Engn Res Ctr, Changchun 130061, Peoples R China
[4] Hohai Univ, Sch Earth Sci & Engn, Nanjing 211100, Peoples R China
基金
中国国家自然科学基金;
关键词
low-field NMR; SSMR magnet array; transverse relaxation time; spin echo; SQP algorithm; UNILATERAL MAGNET; NMR SENSOR;
D O I
10.1088/1361-6501/ad9e16
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Single-sided magnetic resonance (SSMR) technology has a compact structure and great potential for use in mobile and nondestructive detection of large aqueous materials. As the detection depth increases, the magnetic field gradient generated by the magnetic resonance magnet placed on one side weakens, leading to a large distortion of T2, thereby significantly impeding accurate estimation of the pore size distribution within the detection target. In this study, to address this problem, the distortion in the region of interest (ROI) is significantly reduced by optimizing the size and arrangement of the SSMR magnet array. First, to evaluate the T2 distortion within the ROI, we developed a T2 distortion loss function based on alpha and theta, which are key parameters of the spin echo (SE) signal. We then combined the nonlinear constraints with the loss function to form a Lagrangian function, which was solved via the Newton iteration method to obtain the magnet array parameters. The magnet array is called the AT magnet array. The T2 distortion was quantitatively evaluated by calculating the SE signal generated by the AT magnet array in the ROI. Furthermore, we compared the detection results obtained with the AT and the semi-annular (SA) magnet array. The results showed that within the 3 cm x 3 cm target range of a 10 cm depth, the AT magnet array had a smaller T2 distortion of only 1.3%. After the ROI was expanded to 5 cm x 5 cm, the T2 distortion of the SE signal measured by the AT magnet array was 6%, which met the SSMR detection accuracy requirements in this range. Therefore, the optimized design of the magnet array based on alpha and theta provides a theoretical basis for obtaining SE signals with low T2 distortion at large depths and over large areas via SSMR.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] CALCULATED T1 AND T2 PARAMETERS IN MAGNETIC-RESONANCE-IMAGING - THEIR ACCURACY, EASE OF APPLICATION AND EFFICACY IN THE CLINICAL SITUATION
    CONDON, B
    PATTERSON, J
    WYPER, D
    ROWAN, J
    PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (03): : 313 - 313
  • [32] Accuracy and Impact on Patient Management of New Tools for Diagnosis of Sepsis: Experience with the T2 Magnetic Resonance Bacteria Panel
    Paggi, Riccardo
    Cenci, Elio
    De Socio, Giuseppe Vittorio
    Belati, Alessandra
    Marini, Daniele
    Gili, Alessio
    Camilloni, Barbara
    Mencacci, Antonella
    PATHOGENS, 2021, 10 (09):
  • [33] Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan
    Maciej W Garbowski
    John-Paul Carpenter
    Gillian Smith
    Michael Roughton
    Mohammed H Alam
    Taigang He
    Dudley J Pennell
    John B Porter
    Journal of Cardiovascular Magnetic Resonance, 16
  • [34] Biopsy-based calibration of T2*magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan
    Garbowski, Maciej W.
    Carpenter, John-Paul
    Smith, Gillian
    Roughton, Michael
    Alam, Mohammed H.
    He, Taigang
    Pennell, Dudley J.
    Porter, John B.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [35] A single breath-hold multiecho T2*cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload
    Westwood, M
    Anderson, LJ
    Firmin, DN
    Gatehouse, PD
    Charrier, CC
    Wonke, B
    Pennell, DJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 18 (01) : 33 - 39
  • [36] In vivo calibration of the T2*cardiovascular magnetic resonance method at 1.5 T for estimation of cardiac iron in a minipig model of transfusional iron overload
    Jensen, Peter Diedrich
    Nielsen, Asbjorn Haaning
    Simonsen, Carsten Wiberg
    Baandrup, Ulrik Thorngren
    Jensen, Svend Eggert
    Bogsted, Martin
    Magnusdottir, Sigridur Olga
    Jensen, Anne Birthe Helweg
    Kjaergaard, Benedict
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [37] In vivo calibration of the T2* cardiovascular magnetic resonance method at 1.5 T for estimation of cardiac iron in a minipig model of transfusional iron overload
    Peter Diedrich Jensen
    Asbjørn Haaning Nielsen
    Carsten Wiberg Simonsen
    Ulrik Thorngren Baandrup
    Svend Eggert Jensen
    Martin Bøgsted
    Sigridur Olga Magnusdottir
    Anne Birthe Helweg Jensen
    Benedict Kjaergaard
    Journal of Cardiovascular Magnetic Resonance, 23
  • [38] Estimation of liver function using T2* mapping on gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid enhanced magnetic resonance imaging
    Katsube, Takashi
    Okada, Masahiro
    Kumano, Seishi
    Imaoka, Izumi
    Kagawa, Yuki
    Hori, Masatoshi
    Ishii, Kazunari
    Tanigawa, Noboru
    Imai, Yasuharu
    Kudo, Masatoshi
    Murakami, Takamichi
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (07) : 1460 - 1464
  • [39] Development and optimization of T2 weighted methods with reduced RF power deposition (Hyperecho-TSE) for magnetic resonance imaging
    Weigel, Matthias
    Hennig, Juergen
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2008, 18 (03): : 151 - 161
  • [40] Improved Interpretation of Nuclear Magnetic Resonance T1 and T2 Distributions for Permeability Prediction: Simulation of Diffusion Coupling for a Fractal Cluster of Pores
    Pape, H.
    Clauser, C.
    PURE AND APPLIED GEOPHYSICS, 2009, 166 (5-7) : 949 - 968