Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength

被引:0
|
作者
Sartorio, Francesco [1 ]
Lippi, Lorenzo [2 ]
Vercelli, Stefano [3 ]
Gallo, Federica [4 ]
Zanin, Davide [5 ]
Bergesio, Sara [6 ,7 ]
de Sire, Alessandro [8 ,9 ]
Invernizzi, Marco [10 ]
机构
[1] IRCCS, ICS Maugeri SPA SB, Inst Veruno, Div Phys Med & Rehabil, I-28010 Veruno, Novara, Italy
[2] Semmelweis Univ Budapest, Dept Sci Res, Campus LUdeS,Off Campus, H-1085 Budapest, Hungary
[3] Univ Appl Sci & Arts Southern, Dept Business Econ Hlth & Social Care, Rehabil Res Lab 2rLab, CH-6928 Lugano, Switzerland
[4] Local Hlth Author 1 Cuneo, Epidemiol Unit, I-12100 Cuneo, Italy
[5] Humanitas Clin Fornaca Sessant, Hand Surg & Microsurg Unit, I-10128 Turin, Italy
[6] Extended Care Chianoc, I-12038 Savigliano, Cuneo, Italy
[7] Arete Wellness Performance & Rehab Lab, I-12038 Savigliano, Cuneo, Italy
[8] Univ Catanzaro Magna Graecia, Dept Med & Surg Sci, I-88100 Catanzaro, Italy
[9] Univ Catanzaro Magna Graecia, MusculoSkeletalHlth UMG, Res Ctr Musculoskeletal Hlth, I-88100 Catanzaro, Italy
[10] Univ Piemonte Orientale, Dept Hlth Sci, I-28100 Novara, Italy
关键词
Hand grip strength; Health Technology; Digital Innovation; Rehabilitation; ELECTRONIC DYNAMOMETER; JAMAR; FORCE; AGREEMENT; ADULTS;
D O I
10.1186/s12891-024-08222-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionHand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar (R) hydraulic dynamometer (JD), the gold standard.MethodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices.To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.MethodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices.To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.ResultsAll ICCs show high inter-reliability; the results are very similar for both dynamometers. The value of the adjusted ICC of NOD was 0.90. For validity, Pearson correlations of NOD towards JD and JD-adapted-grip were high (r = 0.87 and 0.88). However, the LoA and the plots of Bland-Altman demonstrated that there is no agreement between NOD and JD and between NOD and JD-adapted-grip, with NOD showing lower mean scores than JD.ConclusionsNOD is a reliable and valid instrument for HGS. However, even if it cannot be considered interchangeable with JD because there is no agreement between them in free-living adults, NOD is easier to carry than other dynamometers, it has a Bluetooth (R) connection with a free App and it is a multi-purpose tool that should be considered both in daily practice and in clinical settings.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer
    Ieiri, Akira
    Tushima, Eiki
    Ishida, Kazuhiro
    Inoue, Masahiro
    Kanno, Taiki
    Masuda, Takeshi
    PHYSIOTHERAPY THEORY AND PRACTICE, 2015, 31 (02) : 146 - 152
  • [22] Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study
    Hebert, Luc J.
    Maltais, Desiree B.
    Lepage, Celine
    Saulnier, Joanne
    Crete, Melanie
    Perron, Marc
    PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 289 - 299
  • [23] HAND-HELD DYNAMOMETER POSITIONING IMPACTS DISCOMFORT DURING QUADRICEPS STRENGTH TESTING: A VALIDITY AND RELIABILITY STUDY
    Hansen, Evan M.
    McCartney, Caitlyn N.
    Sweeney, Ryan S.
    Palimenio, Marcus R.
    Grindstaff, Terry L.
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2015, 10 (01): : 62 - 68
  • [24] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER APPLIED TO ADULTS WITH MENTAL-RETARDATION
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (06): : 535 - 539
  • [25] The concurrent validity and intrarater reliability of a hand-held dynamometer for the assessment of neck strength in semi-professional rugby union players
    Ashall, Adam
    Dobbin, Nick
    Thorpe, Cari
    PHYSICAL THERAPY IN SPORT, 2021, 49 : 229 - 235
  • [26] Concurrent validity of a fixated hand-held dynamometer for measuring isometric knee extension strength in adults with congenital heart disease
    Nordin, Fredrik
    Nyberg, Andre
    Sandberg, Camilla
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2020, 22 (04) : 206 - 211
  • [27] Clinical assessment of hip strength using a hand-held dynamometer is reliable
    Thorborg, K.
    Petersen, J.
    Magnusson, S. P.
    Holmich, P.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2010, 20 (03) : 493 - 501
  • [28] RELIABILITY OF MUSCLE STRENGTH MEASURES OBTAINED WITH A HAND-HELD DYNAMOMETER IN AN ELDERLY POPULATION
    Buckinx, F.
    Croisier, J. L.
    Reginster, J. -Y.
    Dardenne, N.
    Beaudart, C.
    Slomian, J.
    Bruyere, O.
    OSTEOPOROSIS INTERNATIONAL, 2015, 26 : S161 - S161
  • [29] Reliability of muscle strength measures obtained with a hand-held dynamometer in an elderly population
    Buckinx, Fanny
    Croisier, Jean-Louis
    Reginster, Jean-Yves
    Dardenne, Nadia
    Beaudart, Charlotte
    Slomian, Justine
    Leonard, Sylvain
    Bruyere, Olivier
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2017, 37 (03) : 332 - 340
  • [30] Comparison of Reliability of Isometric Leg Muscle Strength Measurements Made Using a Hand-Held Dynamometer with and without a Restraining Belt
    Katoh, Munenori
    Yamasaki, Hiroshi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2009, 21 (01) : 37 - 42