HAND-HELD DYNAMOMETER POSITIONING IMPACTS DISCOMFORT DURING QUADRICEPS STRENGTH TESTING: A VALIDITY AND RELIABILITY STUDY

被引:0
|
作者
Hansen, Evan M. [1 ]
McCartney, Caitlyn N. [1 ]
Sweeney, Ryan S. [1 ]
Palimenio, Marcus R. [1 ]
Grindstaff, Terry L. [1 ]
机构
[1] Creighton Univ, Dept Phys Therapy, Omaha, NE 68178 USA
来源
关键词
knee extension; muscle; quadriceps; torque;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Purpose/Background: A belt-stabilized hand-held dynamometer (HHD) offers the ability to quantify quadriceps muscle strength in a clinical environment, but a limitation is participant discomfort at the interface between the HHD and the tibia. The purpose of this study was to quantify the level of discomfort associated with a modified belt-stabilized HHD configuration compared to a standard belt-stabilized configuration and an isokinetic dynamometer. The secondary purpose of this study was to determine the validity and reliability of a modified configuration used to measure quadriceps strength compared to the "gold-standard" isokinetic dynamometer. Methods: Twenty healthy participants (5 males, 15 females; age = 24.7 +/- 2.2 years, height = 171.1 +/- 8.8 cm, mass = 72.0 +/- 18.7 kg) performed maximal knee extension isometric contractions during each of three testing conditions: isokinetic dynamometer, standard configuration with HHD placement on the tibia, and an alternative configuration with the HHD interfaced with the leg of a table. Discomfort was quantified using a Visual Analog Scale (VAS). Differences in discomfort and torque (N.m) associated with the testing positions were determined using Friedman test or repeated measures analysis of variance. Validity was quantified using Pearson correlations and within-session intrarater reliability was determined using an intraclass correlation coefficient (ICC2,1) and associated confidence intervals (95% CI). Results: The isokinetic dynamometer configuration resulted in the least discomfort (p < .01) and the modified configuration was more comfortable than the standard configuration (p = .003). There was a significant correlation between measures from the isokinetic dynamometer and the standard configuration (r = .87) and modified configuration (r = .93). Within-session intrarater reliability was good for both the standard configuration (ICC2,1 = 0.93) and modified configuration (ICC2,1 = 0.93) conditions. Conclusions: The use of the modified belt-stabilized HHD configuration, where the HHD was interfaced with the leg of a table, offers a more comfortable alternative compared to the standard belt-stabilized configuration to obtain isometric quadriceps strength measures in a clinical environment. This configuration is also a valid and reliable alternative to the "gold-standard" isokinetic dynamometer when testing isometric quadriceps strength at 90 degrees of knee flexion.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [1] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    [J]. JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2023,
  • [2] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [3] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [4] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    [J]. JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [5] Validity And Reliability Of Hand-held Dynamometer In Assessing Isometric Leg Strength In Older Adults
    Lee, Chong-Do
    Lee, Samuel
    [J]. MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 477 - 477
  • [6] INTERDEVICE RELIABILITY AND VALIDITY ASSESSMENT OF THE NICHOLAS HAND-HELD DYNAMOMETER
    TRUDELLEJACKSON, E
    JACKSON, AW
    FRANKOWSKI, CM
    LONG, KM
    MESKE, NB
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (06): : 302 - 306
  • [7] The Concurrent Validity of a Hand-held versus a Stationary Dynamometer in Testing Isometric Shoulder Strength
    Roy, Jean-Sebastien
    MacDermid, Joy C.
    Orton, Brock
    Tran, Thomas
    Faber, Kenneth J.
    Drosdowech, Darren
    Athwal, George S.
    [J]. JOURNAL OF HAND THERAPY, 2009, 22 (04) : 320 - 326
  • [8] Reliability of the Hand-Held Dynamometer During Hip Isometric Strength Testing Both With and Without a Stabilization Strap
    Beard, Megan Q.
    Boland, Samantha A.
    Gribble, Phillip A.
    [J]. INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2020, 25 (01): : 37 - 42
  • [9] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    [J]. INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [10] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    [J]. PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57