Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength

被引:0
|
作者
Sartorio, Francesco [1 ]
Lippi, Lorenzo [2 ]
Vercelli, Stefano [3 ]
Gallo, Federica [4 ]
Zanin, Davide [5 ]
Bergesio, Sara [6 ,7 ]
de Sire, Alessandro [8 ,9 ]
Invernizzi, Marco [10 ]
机构
[1] IRCCS, ICS Maugeri SPA SB, Inst Veruno, Div Phys Med & Rehabil, I-28010 Veruno, Novara, Italy
[2] Semmelweis Univ Budapest, Dept Sci Res, Campus LUdeS,Off Campus, H-1085 Budapest, Hungary
[3] Univ Appl Sci & Arts Southern, Dept Business Econ Hlth & Social Care, Rehabil Res Lab 2rLab, CH-6928 Lugano, Switzerland
[4] Local Hlth Author 1 Cuneo, Epidemiol Unit, I-12100 Cuneo, Italy
[5] Humanitas Clin Fornaca Sessant, Hand Surg & Microsurg Unit, I-10128 Turin, Italy
[6] Extended Care Chianoc, I-12038 Savigliano, Cuneo, Italy
[7] Arete Wellness Performance & Rehab Lab, I-12038 Savigliano, Cuneo, Italy
[8] Univ Catanzaro Magna Graecia, Dept Med & Surg Sci, I-88100 Catanzaro, Italy
[9] Univ Catanzaro Magna Graecia, MusculoSkeletalHlth UMG, Res Ctr Musculoskeletal Hlth, I-88100 Catanzaro, Italy
[10] Univ Piemonte Orientale, Dept Hlth Sci, I-28100 Novara, Italy
关键词
Hand grip strength; Health Technology; Digital Innovation; Rehabilitation; ELECTRONIC DYNAMOMETER; JAMAR; FORCE; AGREEMENT; ADULTS;
D O I
10.1186/s12891-024-08222-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionHand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar (R) hydraulic dynamometer (JD), the gold standard.MethodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices.To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.MethodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices.To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.ResultsAll ICCs show high inter-reliability; the results are very similar for both dynamometers. The value of the adjusted ICC of NOD was 0.90. For validity, Pearson correlations of NOD towards JD and JD-adapted-grip were high (r = 0.87 and 0.88). However, the LoA and the plots of Bland-Altman demonstrated that there is no agreement between NOD and JD and between NOD and JD-adapted-grip, with NOD showing lower mean scores than JD.ConclusionsNOD is a reliable and valid instrument for HGS. However, even if it cannot be considered interchangeable with JD because there is no agreement between them in free-living adults, NOD is easier to carry than other dynamometers, it has a Bluetooth (R) connection with a free App and it is a multi-purpose tool that should be considered both in daily practice and in clinical settings.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Validity And Reliability Of Hand-held Dynamometer In Assessing Isometric Leg Strength In Older Adults
    Lee, Chong-Do
    Lee, Samuel
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 477 - 477
  • [2] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2024, 6 (04) : 386 - 393
  • [3] INTERDEVICE RELIABILITY AND VALIDITY ASSESSMENT OF THE NICHOLAS HAND-HELD DYNAMOMETER
    TRUDELLEJACKSON, E
    JACKSON, AW
    FRANKOWSKI, CM
    LONG, KM
    MESKE, NB
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 20 (06): : 302 - 306
  • [4] The Concurrent Validity of a Hand-held versus a Stationary Dynamometer in Testing Isometric Shoulder Strength
    Roy, Jean-Sebastien
    MacDermid, Joy C.
    Orton, Brock
    Tran, Thomas
    Faber, Kenneth J.
    Drosdowech, Darren
    Athwal, George S.
    JOURNAL OF HAND THERAPY, 2009, 22 (04) : 320 - 326
  • [5] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [6] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196
  • [7] Reliability and validity of measurements of cervical retraction strength obtained with a hand-held dynamometer
    Tudini, Frank
    Myers, Bradley
    Bohannon, Richard
    JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2019, 27 (04) : 222 - 228
  • [8] Reliability and validity of a custom-made instrument including a hand-held dynamometer for measuring trunk muscle strength
    Jubany, Julia
    Busquets, Albert
    Marina, Michel
    Cos, Francesc
    Angulo-Barroso, Rosa
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2015, 28 (02) : 317 - 326
  • [9] Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study
    Kim, Won Kuel
    Kim, Don-Kyu
    Seo, Kyung Mook
    Kang, Si Hyun
    ANNALS OF REHABILITATION MEDICINE-ARM, 2014, 38 (01): : 84 - 93
  • [10] Strength assessment in postpolio syndrome: Validity of a hand-held dynamometer in detecting change
    Nollet, F
    Beelen, A
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (10): : 1316 - 1323