Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

被引:66
|
作者
Kim, Won Kuel [1 ]
Kim, Don-Kyu [1 ]
Seo, Kyung Mook [1 ]
Kang, Si Hyun [1 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Phys Med & Rehabil, 102 Heukseok Ro, Seoul 156755, South Korea
来源
ANNALS OF REHABILITATION MEDICINE-ARM | 2014年 / 38卷 / 01期
关键词
Muscle strength dynamometer; Isometric contraction; Physical restraint; Dimensional measurement accuracy; Knee joint;
D O I
10.5535/arm.2014.38.1.84
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35 degrees angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength.
引用
收藏
页码:84 / 93
页数:10
相关论文
共 50 条
  • [1] Validity And Reliability Of Hand-held Dynamometer In Assessing Isometric Leg Strength In Older Adults
    Lee, Chong-Do
    Lee, Samuel
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (09) : 477 - 477
  • [2] Reliability and Validity of Hand-Held Dynamometer and Hand-Held Sphygmomanometer for Testing Shoulder Isometric External and Internal Rotator Muscles Strength
    Bettariga, Francesco
    Lopomo, Nicola Francesco
    Civera, Fabio
    Lazzarini, Stefano Giuseppe
    Mantovani, Lisa
    Maestroni, Luca
    JOURNAL OF SCIENCE IN SPORT AND EXERCISE, 2024, 6 (04) : 386 - 393
  • [3] Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength
    Sartorio, Francesco
    Lippi, Lorenzo
    Vercelli, Stefano
    Gallo, Federica
    Zanin, Davide
    Bergesio, Sara
    de Sire, Alessandro
    Invernizzi, Marco
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [4] COMPARATIVE STUDY ON THE ASSESSMENT OF THE STRENGTH OF THE KNEE EXTENSOR AND FLEXOR MUSCLES BY HAND-HELD DYNAMOMETER AND ISOKINETIC DYNAMOMETER
    Muff, Guillaume
    Masat, Julien
    Lecocq, Jehan
    Meyer, Alain
    Isner-Horobeti, Marie-Eve
    ACTA PHYSIOLOGICA, 2015, 214 : 46 - 46
  • [5] Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer
    Suzuki, Terumi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 967 - 971
  • [6] Test-retest Reliability of Isometric Knee Extension Muscle Strength Measurement using a Hand-held Dynamometer and a Belt: Study of Hemiplegic Patients
    Katoh, Munenori
    Asuma, Hitomi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2011, 23 (01) : 25 - 28
  • [7] The Concurrent Validity of a Hand-held versus a Stationary Dynamometer in Testing Isometric Shoulder Strength
    Roy, Jean-Sebastien
    MacDermid, Joy C.
    Orton, Brock
    Tran, Thomas
    Faber, Kenneth J.
    Drosdowech, Darren
    Athwal, George S.
    JOURNAL OF HAND THERAPY, 2009, 22 (04) : 320 - 326
  • [8] Reliability of Isometric Knee Extension Muscle Strength Measurement Using a Hand-held Dynamometer with a Belt: A Study of Test-retest Reliability in Healthy Elderly Subjects
    Katoh, Munenori
    Isozaki, Koji
    Sakanoue, Noboru
    Miyahara, Takuya
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2010, 22 (04) : 359 - 363
  • [9] VALIDITY AND RELIABILITY OF A HAND-HELD DYNAMOMETER WITH 2 POPULATIONS
    SURBURG, PR
    SUOMI, R
    POPPY, WK
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 229 - 234
  • [10] Reliability and Validity of the Hand-Held Dynamometer in Measuring Hip External Rotation Strength
    Quinlevan, Megan
    Boland, Samantha
    Dodge, Erica
    Gribble, Phillip
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 196 - 196