Reliability and Validity of Isometric Knee Extensor Strength Test With Hand-Held Dynamometer Depending on Its Fixation: A Pilot Study

被引:66
|
作者
Kim, Won Kuel [1 ]
Kim, Don-Kyu [1 ]
Seo, Kyung Mook [1 ]
Kang, Si Hyun [1 ]
机构
[1] Chung Ang Univ, Coll Med, Dept Phys Med & Rehabil, 102 Heukseok Ro, Seoul 156755, South Korea
来源
ANNALS OF REHABILITATION MEDICINE-ARM | 2014年 / 38卷 / 01期
关键词
Muscle strength dynamometer; Isometric contraction; Physical restraint; Dimensional measurement accuracy; Knee joint;
D O I
10.5535/arm.2014.38.1.84
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective To determine the reliability and validity of hand-held dynamometer (HHD) depending on its fixation in measuring isometric knee extensor strength by comparing the results with an isokinetic dynamometer. Methods Twenty-seven healthy female volunteers participated in this study. The subjects were tested in seated and supine position using three measurement methods: isometric knee extension by isokinetic dynamometer, non-fixed HHD, and fixed HHD. During the measurement, the knee joints of subjects were fixed at a 35 degrees angle from the extended position. The fixed HHD measurement was conducted with the HHD fixed to distal tibia with a Velcro strap; non-fixed HHD was performed with a hand-held method without Velcro fixation. All the measurements were repeated three times and among them, the maximum values of peak torque were used for the analysis. Results The data from the fixed HHD method showed higher validity than the non-fixed method compared with the results of the isokinetic dynamometer. Pearson correlation coefficients (r) between fixed HHD and isokinetic dynamometer method were statistically significant (supine-right: r=0.806, p<0.05; seating-right: r=0.473, p<0.05; supine-left: r=0.524, p<0.05), whereas Pearson correlation coefficients between non-fixed dynamometer and isokinetic dynamometer methods were not statistically significant, except for the result of the supine position of the left leg (r=0.384, p<0.05). Both fixed and non-fixed HHD methods showed excellent inter-rater reliability. However, the fixed HHD method showed a higher reliability than the non-fixed HHD method by considering the intraclass correlation coefficient (fixed HHD, 0.952-0.984; non-fixed HHD, 0.940-0.963). Conclusion Fixation of HHD during measurement in the supine position increases the reliability and validity in measuring the quadriceps strength.
引用
收藏
页码:84 / 93
页数:10
相关论文
共 50 条
  • [21] Reliability of isometric knee extension muscle strength measurements made by a hand-held dynamometer and a belt: a comparison of two types of device
    Katoh, Munenori
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2015, 27 (03) : 851 - 854
  • [22] Knee extensor strength measured using a Biodex dynamometer and an adapted hand held dynamometer
    Clements, Shaun
    Samuel, Dinesh
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2014, 21 (06): : 274 - 278
  • [23] Reliability of hand-held dynamometry in assessment of knee extensor strength after hip fracture
    Mag, R
    Doherty, TJ
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2004, 83 (11) : 813 - 818
  • [24] Reliability of hand-held dynamometry in assessment of knee extensor strength following hip fracture
    Roy, MA
    Miller, TA
    Doherty, TJ
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2004, 12 (03) : 329 - 329
  • [25] Reliability of the Hand-Held Dynamometer During Hip Isometric Strength Testing Both With and Without a Stabilization Strap
    Beard, Megan Q.
    Boland, Samantha A.
    Gribble, Phillip A.
    INTERNATIONAL JOURNAL OF ATHLETIC THERAPY & TRAINING, 2020, 25 (01): : 37 - 42
  • [26] Reliability and validity of eccentric strength measurement of the shoulder abductor muscles using a hand-held dynamometer
    Karabay, Damla
    Yesilyaprak, Sevgi Sevi
    Picak, Gonca Sahiner
    PHYSICAL THERAPY IN SPORT, 2020, 43 : 52 - 57
  • [27] RELIABILITY, COMPARABILITY, AND VALIDITY OF FOOT INVERSION AND EVERSION STRENGTH MEASUREMENTS USING A HAND-HELD DYNAMOMETER
    Alfuth, Martin
    Murielle, Magali
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2016, 11 (01): : 72 - 84
  • [28] Same-session and between-day intra-rater reliability of hand-held dynamometer measurements of isometric shoulder extensor strength
    Awatani, Takenori
    Mori, Seigo
    Shinohara, Junji
    Koshiba, Hiroya
    Nariai, Miki
    Tatsumi, Yasutaka
    Nagata, Akinori
    Morikita, Ikuhiro
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2016, 28 (03) : 936 - 939
  • [29] Commentary on "Isometric Muscle Strength in Youth Assessed by Hand-held Dynamometry: A Feasibility, Reliability, and Validity Study"
    Nervik, Deborah
    Nicols, Jennifer Parent
    PEDIATRIC PHYSICAL THERAPY, 2011, 23 (03) : 300 - 300
  • [30] Interrater reliability of hand-held dynamometry estimates of isometric knee extensor and flexor muscle force.
    Dunn, JC
    Harris, M
    Iversen, MD
    ARTHRITIS AND RHEUMATISM, 2001, 44 (09): : S389 - S389