Reliability and validity of the hand-held dynamometer "NOD": a new instrument for assessment of isometric grip strength

被引:0
|
作者
Sartorio, Francesco [1 ]
Lippi, Lorenzo [2 ]
Vercelli, Stefano [3 ]
Gallo, Federica [4 ]
Zanin, Davide [5 ]
Bergesio, Sara [6 ,7 ]
de Sire, Alessandro [8 ,9 ]
Invernizzi, Marco [10 ]
机构
[1] IRCCS, ICS Maugeri SPA SB, Inst Veruno, Div Phys Med & Rehabil, I-28010 Veruno, Novara, Italy
[2] Semmelweis Univ Budapest, Dept Sci Res, Campus LUdeS,Off Campus, H-1085 Budapest, Hungary
[3] Univ Appl Sci & Arts Southern, Dept Business Econ Hlth & Social Care, Rehabil Res Lab 2rLab, CH-6928 Lugano, Switzerland
[4] Local Hlth Author 1 Cuneo, Epidemiol Unit, I-12100 Cuneo, Italy
[5] Humanitas Clin Fornaca Sessant, Hand Surg & Microsurg Unit, I-10128 Turin, Italy
[6] Extended Care Chianoc, I-12038 Savigliano, Cuneo, Italy
[7] Arete Wellness Performance & Rehab Lab, I-12038 Savigliano, Cuneo, Italy
[8] Univ Catanzaro Magna Graecia, Dept Med & Surg Sci, I-88100 Catanzaro, Italy
[9] Univ Catanzaro Magna Graecia, MusculoSkeletalHlth UMG, Res Ctr Musculoskeletal Hlth, I-88100 Catanzaro, Italy
[10] Univ Piemonte Orientale, Dept Hlth Sci, I-28100 Novara, Italy
关键词
Hand grip strength; Health Technology; Digital Innovation; Rehabilitation; ELECTRONIC DYNAMOMETER; JAMAR; FORCE; AGREEMENT; ADULTS;
D O I
10.1186/s12891-024-08222-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionHand grip strength (HGS) is an important measure in a physiotherapy assessment and for this purpose it is necessary to have valid and reliable instruments to measure it. In this study we aimed at investigating the reliability, validity, and agreement of the new hand-held dynamometer NOD (OT-Bioelettronica, To-Italy) compared to Jamar (R) hydraulic dynamometer (JD), the gold standard.MethodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices.To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.MethodsFifty healthy subjects were selected; 9 trials for the dominant hand and 9 trials for the non-dominant hand were administrated to each of them: 3 trials of HGS with the JD in rung #3, 3 trials with the JD-adapted-grip (like the NOD one), and 3 trials with NOD. To verify the reliability of NOD, the Intraclass Correlation Coefficient (ICC 3,1) was calculated with a mixed effects model with the addition of adjustment variables (age, gender, dominant / non-dominant limb, trials). The model used single HGS measurements to estimate variance components, so reflecting both degree of correspondence and agreement among devices.To assess concurrent validity NOD was compared to the "gold standard" JD, in terms of ICCs and through Pearson correlation. The agreement between the methods of measurement was calculated with the Limits of Agreement (LoA) and the plots of Bland-Altman.ResultsAll ICCs show high inter-reliability; the results are very similar for both dynamometers. The value of the adjusted ICC of NOD was 0.90. For validity, Pearson correlations of NOD towards JD and JD-adapted-grip were high (r = 0.87 and 0.88). However, the LoA and the plots of Bland-Altman demonstrated that there is no agreement between NOD and JD and between NOD and JD-adapted-grip, with NOD showing lower mean scores than JD.ConclusionsNOD is a reliable and valid instrument for HGS. However, even if it cannot be considered interchangeable with JD because there is no agreement between them in free-living adults, NOD is easier to carry than other dynamometers, it has a Bluetooth (R) connection with a free App and it is a multi-purpose tool that should be considered both in daily practice and in clinical settings.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] COMPARATIVE STUDY ON THE ASSESSMENT OF THE STRENGTH OF THE KNEE EXTENSOR AND FLEXOR MUSCLES BY HAND-HELD DYNAMOMETER AND ISOKINETIC DYNAMOMETER
    Muff, Guillaume
    Masat, Julien
    Lecocq, Jehan
    Meyer, Alain
    Isner-Horobeti, Marie-Eve
    ACTA PHYSIOLOGICA, 2015, 214 : 46 - 46
  • [42] INTERTESTER RELIABILITY OF THE HAND-HELD DYNAMOMETER FOR WRIST FLEXION AND EXTENSION
    RHEAULT, W
    BEAL, JL
    KUBIK, KR
    NOWAK, TA
    SHEPLEY, JA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1989, 70 (13): : 907 - 910
  • [43] Reliability of hand-held dynamometer for assessment of electrically induced torque in critically ill patients
    Silva, Vinicius
    Santana, Larissa
    Pinto, Natalia
    Durigan, Joao Luiz
    Cipriano, Gerson
    Urache, Luciana
    Silva, Paulo Eugenio
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [44] Validity and Reliability of Hand-Held Dynamometry for Abdominal Flexion Muscular Assessment
    Tarca, Brett D.
    Wycherley, Thomas P.
    Meade, Anthony
    Bennett, Paul
    Ferrar, Katia E.
    JOURNAL OF SPORT REHABILITATION, 2021, 30 (02) : 343 - 346
  • [45] INTRATESTER RELIABILITY OF STRENGTH TESTING IN DYSTROPHIC AND NORMAL-CHILDREN USING A HAND-HELD DYNAMOMETER
    STUBERG, WA
    METCALF, WK
    PHYSICAL THERAPY, 1986, 66 (05): : 800 - 800
  • [46] Reliability of Hand-Held Dynamometer Measurement for Thumb Palmar Abduction Strength in Carpal Tunnel Syndrome
    Doi, Kazuteru
    Yasui, Noritada
    Isomura, Yuya
    Tagawa, Masafumi
    Hattori, Yasunori
    Sakamoto, Sotetsu
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2025,
  • [47] Reliability and validity of the Grip-Ball dynamometer for grip-strength measurement
    Chkeir, Aly
    Jaber, Rana
    Hewson, David J.
    Duchene, Jacques
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1996 - 1999
  • [48] Reliability and validity of an electronic dynamometer for measuring grip strength COMMENT
    Fitinghoff, Helene
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2011, 18 (05): : 265 - 265
  • [49] Reliability and validity of hand-held dynamometry for assessing lower limb muscle strength
    Lipovsek, Tjasa
    Kacin, Alan
    Puh, Urska
    ISOKINETICS AND EXERCISE SCIENCE, 2022, 30 (03) : 231 - 240
  • [50] Strength of the intrinsic muscles of the hand measured with a hand-held dynamometer: Reliability in patients with ulnar and median nerve paralysis
    Schreuders, TAR
    Roebroeck, M
    Van der Kar, TJM
    Soeters, JNM
    Hovius, SER
    Stam, HJ
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06): : 560 - 565