Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve

被引:1
|
作者
Dushfunian, David [1 ]
Maroun, Anthony [1 ]
Berhan, Haben [1 ,2 ]
Baraboo, Justin [1 ]
Johnson, Ethan M. [1 ]
Jarvis, Kelly [1 ]
Allen, Bradley D. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60208 USA
[2] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Evanston, IL USA
来源
关键词
4D-flow MRI; Wall shear stress; Aortic stiffness; Pulse wave velocity; Net flow; Reproducibility; PHASE-CONTRAST MRI; THORACIC AORTA; REPRODUCIBILITY; VARIABILITY; EXPRESSION; STIFFNESS; DILATION;
D O I
10.1007/s10554-024-03299-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the reproducibility of important biomarkers like wall shear stress (WSS), pulse wave velocity (PWV), and net flow across two 4D flow MRI imaging protocols with different coverages: aorta-targeted 4D flow MRI (AT4D) and whole-heart 4D flow (WH4D) protocols. Methods: Thirty-eight control subjects (43.2 +/- 10.1 years old; 22 males) and ten patients (45.7 +/- 8.9 years old; 7 males) with bicuspid aortic valve (BAV) were included. Each subject underwent AT4D and WH4D scans. Absolute WSS, PWV, and net flow were assessed for each patient across both protocols and compared using Bland-Altman analysis. Areas of elevated WSS were assessed for BAV patients across different WSS thresholds that define WSS to be elevated compared to a normal population average. A sensitivity analysis was conducted to determine the best WSS threshold at which WH4D-derived areas most closely resemble AT4D-derived areas. Inter-rater reproducibility was evaluated in twenty-four subjects. Results: AT4D and WH4D PWV and WSS estimates demonstrated good agreement (PWV: -0.12 +/- 1.84 m/s, p = 0.4; Median WSS: 0.06 +/- 0.13 Pa, p < 0.01; Maximum WSS: 0.04 +/- 0.27 Pa, p = 0.07). Good agreement was also found for AAo net flow (8.14 +/- 24.86 mL/cycle, p < 0.01). PWV correlated with age across protocols (AT4D: r = 0.68, p < 0.01; WH4D: r = 0.72, p < 0.01). Sensitivity analysis identified a WSS threshold where WH4D-derived areas of elevated WSS most closely resembled AT4D-derived areas. Inter-rater assessment of the tested parameters resulted in a small mean difference percentage of < 3%. Data conclusion: PWV, WSS, and net flow demonstrated good agreement across protocols. The WSS threshold should be adjusted for WH4D estimates to optimally match AT4D-derived output. Reproducibility analysis showed good test-retest agreement. This study demonstrates the reproducibility of certain hemodynamic parameters across two 4D flow MRI protocol.
引用
收藏
页码:137 / 149
页数:13
相关论文
共 50 条
  • [21] Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance
    Pim van Ooij
    Emile S. Farag
    Carmen P. S. Blanken
    Aart J. Nederveen
    Maarten Groenink
    R. Nils Planken
    S. Matthijs Boekholdt
    Journal of Cardiovascular Magnetic Resonance, 23
  • [22] Interpolation time-optimized aortic pulse wave velocity estimation by 4D flow MRI
    Park, Sungho
    Kwon, Minseong
    Nam, Hyojin
    Huh, Hyungkyu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [23] Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance
    van Ooij, Pim
    Farag, Emile S.
    Blanken, Carmen P. S.
    Nederveen, Aart J.
    Groenink, Maarten
    Planken, R. Nils
    Boekholdt, S. Matthijs
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [24] Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease
    José Fernando Rodríguez-Palomares
    Lydia Dux-Santoy
    Andrea Guala
    Raquel Kale
    Giuliana Maldonado
    Gisela Teixidó-Turà
    Laura Galian
    Marina Huguet
    Filipa Valente
    Laura Gutiérrez
    Teresa González-Alujas
    Kevin M. Johnson
    Oliver Wieben
    David García-Dorado
    Arturo Evangelista
    Journal of Cardiovascular Magnetic Resonance, 20
  • [25] Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease
    Rodriguez-Palomares, Jose Fernando
    Dux-Santoy, Lydia
    Guala, Andrea
    Kale, Raquel
    Maldonado, Giuliana
    Teixido-Tura, Gisela
    Galian, Laura
    Huguet, Marina
    Valente, Filipa
    Gutierrez, Laura
    Gonzalez-Alujas, Teresa
    Johnson, Kevin M.
    Wieben, Oliver
    Garcia-Dorado, David
    Evangelista, Arturo
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [26] 4D flow MRI derived aortic hemodynamics multi-year follow-up in repaired coarctation with bicuspid aortic valve
    Soulat, Gilles
    Scott, Michael B.
    Pathrose, Ashitha
    Jarvis, Kelly
    Berhane, Haben
    Allen, Bradley
    Avery, Ryan
    Alsate, Alejandro Roldan
    Rigsby, Cynthia K.
    Markl, Michael
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (09) : 418 - 426
  • [27] Evaluating the disease progression of pediatric bicuspid aortic valve patients using 4D flow MRI data
    Michael J Rose
    Kelly B Jarvis
    Alex J Barker
    Susanne Schnell
    Bradley D Allen
    Joshua D Robinson
    Michael Markl
    Cynthia K Rigsby
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [28] Oscillatory shear stress is elevated in patients with bicuspid aortic valve and aortic regurgitation: a 4D flow cardiovascular magnetic resonance cross-sectional study
    Trenti, Chiara
    Fedak, Paul W. M.
    White, James A.
    Garcia, Julio
    Dyverfeldt, Petter
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (03) : 404 - 412
  • [29] WSSNet: Aortic Wall Shear Stress Estimation Using Deep Learning on 4D Flow MRI
    Ferdian, Edward
    Dubowitz, David J.
    Mauger, Charlene A.
    Wang, Alan
    Young, Alistair A.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [30] IS THERE AN INSTRINSIC ALTERATION OF AORTIC MECHANICAL PROPERTIES IN BICUSPID AORTIC VALVE PATIENTS? REGIONAL COMPARISON WITH TRICUSPID AND MARFAN PATIENTS THROUGH 4D FLOW MRI
    Guala, A.
    Dux-Santoy, L.
    Ruiz-Munoz, A.
    Maldonado, G.
    Teixidor-Tura, G.
    Villalva, N.
    Valente, F.
    Gutierrez, L.
    Galian, L.
    Garcia-Dorado, D.
    Evangelista, A.
    Rodriguez-Palomares, J.
    JOURNAL OF HYPERTENSION, 2018, 36 : E225 - E225