Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve

被引:1
|
作者
Dushfunian, David [1 ]
Maroun, Anthony [1 ]
Berhan, Haben [1 ,2 ]
Baraboo, Justin [1 ]
Johnson, Ethan M. [1 ]
Jarvis, Kelly [1 ]
Allen, Bradley D. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60208 USA
[2] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Evanston, IL USA
来源
关键词
4D-flow MRI; Wall shear stress; Aortic stiffness; Pulse wave velocity; Net flow; Reproducibility; PHASE-CONTRAST MRI; THORACIC AORTA; REPRODUCIBILITY; VARIABILITY; EXPRESSION; STIFFNESS; DILATION;
D O I
10.1007/s10554-024-03299-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the reproducibility of important biomarkers like wall shear stress (WSS), pulse wave velocity (PWV), and net flow across two 4D flow MRI imaging protocols with different coverages: aorta-targeted 4D flow MRI (AT4D) and whole-heart 4D flow (WH4D) protocols. Methods: Thirty-eight control subjects (43.2 +/- 10.1 years old; 22 males) and ten patients (45.7 +/- 8.9 years old; 7 males) with bicuspid aortic valve (BAV) were included. Each subject underwent AT4D and WH4D scans. Absolute WSS, PWV, and net flow were assessed for each patient across both protocols and compared using Bland-Altman analysis. Areas of elevated WSS were assessed for BAV patients across different WSS thresholds that define WSS to be elevated compared to a normal population average. A sensitivity analysis was conducted to determine the best WSS threshold at which WH4D-derived areas most closely resemble AT4D-derived areas. Inter-rater reproducibility was evaluated in twenty-four subjects. Results: AT4D and WH4D PWV and WSS estimates demonstrated good agreement (PWV: -0.12 +/- 1.84 m/s, p = 0.4; Median WSS: 0.06 +/- 0.13 Pa, p < 0.01; Maximum WSS: 0.04 +/- 0.27 Pa, p = 0.07). Good agreement was also found for AAo net flow (8.14 +/- 24.86 mL/cycle, p < 0.01). PWV correlated with age across protocols (AT4D: r = 0.68, p < 0.01; WH4D: r = 0.72, p < 0.01). Sensitivity analysis identified a WSS threshold where WH4D-derived areas of elevated WSS most closely resembled AT4D-derived areas. Inter-rater assessment of the tested parameters resulted in a small mean difference percentage of < 3%. Data conclusion: PWV, WSS, and net flow demonstrated good agreement across protocols. The WSS threshold should be adjusted for WH4D estimates to optimally match AT4D-derived output. Reproducibility analysis showed good test-retest agreement. This study demonstrates the reproducibility of certain hemodynamic parameters across two 4D flow MRI protocol.
引用
收藏
页码:137 / 149
页数:13
相关论文
共 50 条
  • [31] Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI
    Barker, Alex J.
    Lanning, Craig
    Shandas, Robin
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) : 788 - 800
  • [32] Quantification of Hemodynamic Wall Shear Stress in Patients with Bicuspid Aortic Valve Using Phase-Contrast MRI
    Alex J. Barker
    Craig Lanning
    Robin Shandas
    Annals of Biomedical Engineering, 2010, 38 : 788 - 800
  • [33] Characterization of Abnormal Wall Shear Stress Using 4D Flow MRI in Human Bicuspid Aortopathy
    van Ooij, Pim
    Potters, Wouter V.
    Collins, Jeremy
    Carr, Maria
    Carr, James
    Malaisrie, S. Chris
    Fedak, Paul W. M.
    McCarthy, Patrick M.
    Markl, Michael
    Barker, Alex J.
    ANNALS OF BIOMEDICAL ENGINEERING, 2015, 43 (06) : 1385 - 1397
  • [34] Characterization of Abnormal Wall Shear Stress Using 4D Flow MRI in Human Bicuspid Aortopathy
    Pim van Ooij
    Wouter V. Potters
    Jeremy Collins
    Maria Carr
    James Carr
    S. Chris Malaisrie
    Paul W. M. Fedak
    Patrick M. McCarthy
    Michael Markl
    Alex J. Barker
    Annals of Biomedical Engineering, 2015, 43 : 1385 - 1397
  • [35] 4D Flow MRI Pressure Mapping in Patients With Bicuspid Aortic Valve: Feasibility Study With Comparison to Pressure Gradient Quantification
    Burns, Fiona
    Garcia, Julio
    Wu, Cody
    Bristow, Michael S.
    Gao, Xuexin
    Heydari, Bobak
    Lydell, Carmen
    Howarth, Andrew G.
    Fedak, Paul
    White, James A.
    CIRCULATION, 2017, 136
  • [36] Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
    van Ooij, Pim
    Powell, Alexander L.
    Potters, Wouter V.
    Carr, James C.
    Markl, Michael
    Barker, Alex J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 236 - 248
  • [37] Long-Term Predictive Value of 4D Flow MRI in Bicuspid Aortic Valve Patients: A 10-Year Assessment for Aortic Surgery Risk
    Dehadrai, Aniket
    Maroun, Anthony
    Johnson, Ethan
    Berhane, Haben
    Dushfunian, David
    Allen, Bradley
    Markl, Michael
    CIRCULATION, 2024, 150
  • [38] 4D flow MRI demonstrates altered aortic hemodynamics in patients with right-left and right-noncoronary bicuspid aortic valve fusion patterns
    Riti J Mahadevia
    Susanne Schnell
    Pegah Entezari
    Daniel Rinewalt
    Preeti Kansal
    SC Malaisrie
    Patrick McCarthy
    Jeremy Collins
    James Carr
    Alex J Barker
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [39] Quantification of aortic pulse wave velocity in preterm infants using 4D phase contrast MRI
    Kathryn Broadhouse
    Anthony N Price
    Giuliana Durighel
    Anna Finnemore
    David J Cox
    AD Edwards
    Joseph V Hajnal
    Alan Groves
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [40] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Sophia Houriez--Gombaud-Saintonge
    Elie Mousseaux
    Ioannis Bargiotas
    Alain De Cesare
    Thomas Dietenbeck
    Kevin Bouaou
    Alban Redheuil
    Gilles Soulat
    Alain Giron
    Umit Gencer
    Damian Craiem
    Emmanuel Messas
    Emilie Bollache
    Yasmina Chenoune
    Nadjia Kachenoura
    Journal of Cardiovascular Magnetic Resonance, 21