Robustness of 4D flow MRI derived aortic wall shear stress and pulse wave velocity across different protocols in healthy controls and in patients with bicuspid aortic valve

被引:1
|
作者
Dushfunian, David [1 ]
Maroun, Anthony [1 ]
Berhan, Haben [1 ,2 ]
Baraboo, Justin [1 ]
Johnson, Ethan M. [1 ]
Jarvis, Kelly [1 ]
Allen, Bradley D. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60208 USA
[2] Northwestern Univ, McCormick Sch Engn, Dept Biomed Engn, Evanston, IL USA
来源
关键词
4D-flow MRI; Wall shear stress; Aortic stiffness; Pulse wave velocity; Net flow; Reproducibility; PHASE-CONTRAST MRI; THORACIC AORTA; REPRODUCIBILITY; VARIABILITY; EXPRESSION; STIFFNESS; DILATION;
D O I
10.1007/s10554-024-03299-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: To evaluate the reproducibility of important biomarkers like wall shear stress (WSS), pulse wave velocity (PWV), and net flow across two 4D flow MRI imaging protocols with different coverages: aorta-targeted 4D flow MRI (AT4D) and whole-heart 4D flow (WH4D) protocols. Methods: Thirty-eight control subjects (43.2 +/- 10.1 years old; 22 males) and ten patients (45.7 +/- 8.9 years old; 7 males) with bicuspid aortic valve (BAV) were included. Each subject underwent AT4D and WH4D scans. Absolute WSS, PWV, and net flow were assessed for each patient across both protocols and compared using Bland-Altman analysis. Areas of elevated WSS were assessed for BAV patients across different WSS thresholds that define WSS to be elevated compared to a normal population average. A sensitivity analysis was conducted to determine the best WSS threshold at which WH4D-derived areas most closely resemble AT4D-derived areas. Inter-rater reproducibility was evaluated in twenty-four subjects. Results: AT4D and WH4D PWV and WSS estimates demonstrated good agreement (PWV: -0.12 +/- 1.84 m/s, p = 0.4; Median WSS: 0.06 +/- 0.13 Pa, p < 0.01; Maximum WSS: 0.04 +/- 0.27 Pa, p = 0.07). Good agreement was also found for AAo net flow (8.14 +/- 24.86 mL/cycle, p < 0.01). PWV correlated with age across protocols (AT4D: r = 0.68, p < 0.01; WH4D: r = 0.72, p < 0.01). Sensitivity analysis identified a WSS threshold where WH4D-derived areas of elevated WSS most closely resembled AT4D-derived areas. Inter-rater assessment of the tested parameters resulted in a small mean difference percentage of < 3%. Data conclusion: PWV, WSS, and net flow demonstrated good agreement across protocols. The WSS threshold should be adjusted for WH4D estimates to optimally match AT4D-derived output. Reproducibility analysis showed good test-retest agreement. This study demonstrates the reproducibility of certain hemodynamic parameters across two 4D flow MRI protocol.
引用
收藏
页码:137 / 149
页数:13
相关论文
共 50 条
  • [41] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Giron, Alain
    Gencer, Umit
    Craiem, Damian
    Messas, Emmanuel
    Bollache, Emilie
    Chenoune, Yasmina
    Kachenoura, Nadjia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
  • [42] Scan–rescan reproducibility of segmental aortic wall shear stress as assessed by phase-specific segmentation with 4D flow MRI in healthy volunteers
    Roel L. F. van der Palen
    Arno A. W. Roest
    Pieter J. van den Boogaard
    Albert de Roos
    Nico A. Blom
    Jos J. M. Westenberg
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2018, 31 : 653 - 663
  • [43] Reproducibility and inter-observer variability of velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta
    Pim van Ooij
    Alexander L Powell
    Wouter V Potters
    Alex J Barker
    Michael Markl
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [44] Pressure drop mapping using 4D flow MRI in patients with bicuspid aortic valve disease: A novel marker of valvular obstruction
    Hassanabad, Ali Fatehi
    Burns, Fiona
    Bristow, Michael S.
    Lydell, Carmen
    Howarth, Andrew G.
    Heydari, Bobak
    Gao, Xuexin
    Fedak, Paul W. M.
    White, James A.
    Garcia, Julio
    MAGNETIC RESONANCE IMAGING, 2020, 65 : 175 - 182
  • [45] The effects of age at correction of aortic coarctation and recurrent obstruction on adolescent patients: MRI evaluation of wall shear stress and pulse wave velocity
    Juffermans, Joe F.
    Nederend, Ineke
    van den Boogaard, Pieter J.
    Ten Harkel, Arend D. J.
    Hazekamp, Mark G.
    Lamb, Hildo J.
    Roest, Arno A. W.
    Westenberg, Jos J. M.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2019, 3 (01)
  • [46] The effects of age at correction of aortic coarctation and recurrent obstruction on adolescent patients: MRI evaluation of wall shear stress and pulse wave velocity
    Joe F. Juffermans
    Ineke Nederend
    Pieter J. van den Boogaard
    Arend D. J. ten Harkel
    Mark G. Hazekamp
    Hildo J. Lamb
    Arno A. W. Roest
    Jos J. M. Westenberg
    European Radiology Experimental, 3
  • [47] Simultaneous measurements of 3D wall shear stress and pulse wave velocity in the murine aortic arch
    Patrick Winter
    Kristina Andelovic
    Thomas Kampf
    Jan Hansmann
    Peter Michael Jakob
    Wolfgang Rudolf Bauer
    Alma Zernecke
    Volker Herold
    Journal of Cardiovascular Magnetic Resonance, 23
  • [48] Simultaneous measurements of 3D wall shear stress and pulse wave velocity in the murine aortic arch
    Winter, Patrick
    Andelovic, Kristina
    Kampf, Thomas
    Hansmann, Jan
    Jakob, Peter Michael
    Bauer, Wolfgang Rudolf
    Zernecke, Alma
    Herold, Volker
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [49] The effect of aortic valve replacement on 4D flow-measured flow displacement in patients with bicuspid and tri-leaflet aortic valves with severe aortic stenosis
    Richards, C.
    Alfuhied, A.
    Parker, A.
    Aslam, S.
    Debiec, R.
    Mccann, G. P.
    Singh, A.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [50] 4-D flow MRI aortic 3-D hemodynamics and wall shear stress remain stable over short-term follow-up in pediatric and young adult patients with bicuspid aortic valve
    Michael J. Rose
    Cynthia K. Rigsby
    Haben Berhane
    Emilie Bollache
    Kelly Jarvis
    Alex J. Barker
    Susanne Schnell
    Bradley D. Allen
    Joshua D. Robinson
    Michael Markl
    Pediatric Radiology, 2019, 49 : 57 - 67