Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance

被引:0
|
作者
Pim van Ooij
Emile S. Farag
Carmen P. S. Blanken
Aart J. Nederveen
Maarten Groenink
R. Nils Planken
S. Matthijs Boekholdt
机构
[1] Amsterdam University Medical Center,Department of Radiology and Nuclear Medicine
[2] location AMC,Department of Cardiothoracic Surgery
[3] Amsterdam University Medical Center,Department of Cardiology
[4] location AMC,undefined
[5] Amsterdam University Medical Center,undefined
[6] location AMC,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance
    van Ooij, Pim
    Farag, Emile S.
    Blanken, Carmen P. S.
    Nederveen, Aart J.
    Groenink, Maarten
    Planken, R. Nils
    Boekholdt, S. Matthijs
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
  • [2] Evaluation of bicuspid aortic valve and aortic coarctation with 4D flow magnetic resonance imaging
    Hope, Michael D.
    Meadows, Alison K.
    Hope, Thomas A.
    Ordovas, Karen G.
    Reddy, Gautham P.
    Alley, Marcus T.
    Higgins, Charles B.
    CIRCULATION, 2008, 117 (21) : 2818 - 2819
  • [3] Comparing wall shear stress values by using different 4D flow postprocessing tools in cardiovascular magnetic resonance in bicuspid aortic valve disease
    Hanigk, M.
    Burgstaller, E.
    Latus, H.
    Shehu, N.
    Mkrtchyan, N.
    Martinoff, S.
    Ewert, P.
    Stern, H.
    Meierhofer, C.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 355 - 355
  • [4] Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease
    José Fernando Rodríguez-Palomares
    Lydia Dux-Santoy
    Andrea Guala
    Raquel Kale
    Giuliana Maldonado
    Gisela Teixidó-Turà
    Laura Galian
    Marina Huguet
    Filipa Valente
    Laura Gutiérrez
    Teresa González-Alujas
    Kevin M. Johnson
    Oliver Wieben
    David García-Dorado
    Arturo Evangelista
    Journal of Cardiovascular Magnetic Resonance, 20
  • [5] Aortic flow patterns and wall shear stress maps by 4D-flow cardiovascular magnetic resonance in the assessment of aortic dilatation in bicuspid aortic valve disease
    Rodriguez-Palomares, Jose Fernando
    Dux-Santoy, Lydia
    Guala, Andrea
    Kale, Raquel
    Maldonado, Giuliana
    Teixido-Tura, Gisela
    Galian, Laura
    Huguet, Marina
    Valente, Filipa
    Gutierrez, Laura
    Gonzalez-Alujas, Teresa
    Johnson, Kevin M.
    Wieben, Oliver
    Garcia-Dorado, David
    Evangelista, Arturo
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [6] Oscillatory shear stress is elevated in patients with bicuspid aortic valve and aortic regurgitation: a 4D flow cardiovascular magnetic resonance cross-sectional study
    Trenti, Chiara
    Fedak, Paul W. M.
    White, James A.
    Garcia, Julio
    Dyverfeldt, Petter
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (03) : 404 - 412
  • [7] Multiyear Interval Changes in Aortic Wall Shear Stress in Patients with Bicuspid Aortic Valve Assessed by 4D Flow MRI
    Maroun, Anthony
    Scott, Michael B.
    Catania, Roberta
    Berhane, Haben
    Jarvis, Kelly
    Allen, Bradley D.
    Barker, Alex J.
    Markl, Michael
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (06) : 2580 - 2589
  • [8] Comparison of aortic blood flow rotational direction in healthy volunteers and patients with bicuspid aortic valves using volumetric velocity-sensitive cardiovascular magnetic resonance imaging
    Ebel, Sebastian
    Koehler, Benjamin
    Aggarwal, Abhinav
    Preim, Bernhard
    Behrendt, Benjamin
    Jung, Bernd
    Gohmann, Robin F.
    Riekena, Boris
    Borger, Michael
    Lurz, Philipp
    Denecke, Timm
    Grothoff, Matthias
    Gutberlet, Matthias
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (12) : 7973 - 7986
  • [9] 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease
    Lenz, Alexander
    Petersen, Johannes
    Riedel, Christoph
    Weinrich, Julius M.
    Kooijman, Hendrik
    Schoennagel, Bjoern P.
    Adam, Gerhard
    von Kodolitsch, Yskert
    Reichenspurner, Hermann
    Girdauskas, Evaldas
    Bannas, Peter
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [10] 4D flow cardiovascular magnetic resonance for monitoring of aortic valve repair in bicuspid aortic valve disease
    Alexander Lenz
    Johannes Petersen
    Christoph Riedel
    Julius M. Weinrich
    Hendrik Kooijman
    Bjoern P. Schoennagel
    Gerhard Adam
    Yskert von Kodolitsch
    Hermann Reichenspurner
    Evaldas Girdauskas
    Peter Bannas
    Journal of Cardiovascular Magnetic Resonance, 22