Fully quantitative mapping of abnormal aortic velocity and wall shear stress direction in patients with bicuspid aortic valves and repaired coarctation using 4D flow cardiovascular magnetic resonance

被引:0
|
作者
Pim van Ooij
Emile S. Farag
Carmen P. S. Blanken
Aart J. Nederveen
Maarten Groenink
R. Nils Planken
S. Matthijs Boekholdt
机构
[1] Amsterdam University Medical Center,Department of Radiology and Nuclear Medicine
[2] location AMC,Department of Cardiothoracic Surgery
[3] Amsterdam University Medical Center,Department of Cardiology
[4] location AMC,undefined
[5] Amsterdam University Medical Center,undefined
[6] location AMC,undefined
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [31] WSSNet: Aortic Wall Shear Stress Estimation Using Deep Learning on 4D Flow MRI
    Ferdian, Edward
    Dubowitz, David J.
    Mauger, Charlene A.
    Wang, Alan
    Young, Alistair A.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [32] Magnetic resonance imaging-based hemodynamic wall shear stress alters aortic wall tissue biomechanics in bicuspid aortic valve patients
    Nightingale, Miriam
    Scott, Michael Baran
    Sigaeva, Taisiya
    Guzzardi, David
    Garcia, Julio
    Malaisrie, S. Chris
    Mccarthy, Patrick
    Markl, Michael
    Fedak, Paul W. M.
    Martino, Elena S. Di
    Barker, Alex J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 168 (02): : 465 - 476.e5
  • [33] 4D Flow Magnetic Resonance Imaging in Bicuspid Aortic Valve Disease Demonstrates Altered Distribution of Aortic Blood Flow Helicity
    Lorenz, R.
    Bock, J.
    Barker, A. J.
    von Knobelsdorff-Brenkenhoff, F.
    Wallis, W.
    Korvink, J. G.
    Bissell, M. M.
    Schulz-Menger, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1542 - 1553
  • [34] The effect of aortic valve replacement on 4D flow-measured flow displacement in patients with bicuspid and tri-leaflet aortic valves with severe aortic stenosis
    Richards, C.
    Alfuhied, A.
    Parker, A.
    Aslam, S.
    Debiec, R.
    Mccann, G. P.
    Singh, A.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [35] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Sophia Houriez--Gombaud-Saintonge
    Elie Mousseaux
    Ioannis Bargiotas
    Alain De Cesare
    Thomas Dietenbeck
    Kevin Bouaou
    Alban Redheuil
    Gilles Soulat
    Alain Giron
    Umit Gencer
    Damian Craiem
    Emmanuel Messas
    Emilie Bollache
    Yasmina Chenoune
    Nadjia Kachenoura
    Journal of Cardiovascular Magnetic Resonance, 21
  • [36] Comparison of different methods for the estimation of aortic pulse wave velocity from 4D flow cardiovascular magnetic resonance
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Giron, Alain
    Gencer, Umit
    Craiem, Damian
    Messas, Emmanuel
    Bollache, Emilie
    Chenoune, Yasmina
    Kachenoura, Nadjia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (01)
  • [37] Increased Aortic Wall Shear Stress in Marfan Patients Long-Term After Proximal Grafting Assessed by 4D Flow Cardiac Magnetic Resonance
    Saffioti, Alice
    Palumbo, Maria Chiara
    Tak, Katherine
    Votta, Emiliano
    Humphrey, Jay D.
    Wang, Yadong
    Liberman, Nicole
    Singh, Parmanand
    Kim, Jiwon
    Devereux, Richard B.
    Roman, Mary J.
    Gaudino, Mario F.
    Girardi, Leonard N.
    Redaelli, Alberto
    Weinsaft, Jonathan W.
    CIRCULATION, 2022, 146
  • [38] A simplified continuity equation approach to the quantification of stenotic bicuspid aortic valves using velocity-encoded cardiovascular magnetic resonance
    Yap, Sing-Chien
    van Geuns, Robert-Jan
    Meijboom, Folkert J.
    Kirschbaum, Sharon W.
    McGhie, Jackie S.
    Simoons, Maarten L.
    Kilner, Philip J.
    Roos-Hesselink, Jolien W.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2007, 9 (06) : 899 - 906
  • [39] The Assessment of Aortic Pulse Wave Velocity Using 4D Flow Magnetic Resonance Imaging: Methods Comparison
    Houriez-Gombaud-Saintonge, Sophia
    Mousseaux, Elie
    Bargiotas, Ioannis
    De Cesare, Alain
    Dietenbeck, Thomas
    Bouaou, Kevin
    Redheuil, Alban
    Soulat, Gilles
    Gencer, Umit
    Craiem, Damian
    Chenoune, Yasmina
    Kachenoura, Nadjia
    2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [40] Systolic reverse flow derived from 4D flow cardiovascular magnetic resonance in bicuspid aortic valve is associated with aortic dilation and aortic valve stenosis: a cross sectional study in 655 subjects
    Weiss, Elizabeth K.
    Jarvis, Kelly
    Maroun, Anthony
    Malaisrie, S. Chris
    Mehta, Christopher K.
    McCarthy, Patrick M.
    Bonow, Robert O.
    Avery, Ryan J.
    Allen, Bradley D.
    Carr, James C.
    Rigsby, Cynthia K.
    Markl, Michael
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2023, 25 (01)