Effect of metallic materials on magnetic resonance image uniformity: a quantitative experimental study

被引:0
|
作者
Shimamoto, Hiroaki [1 ]
Felemban, Doaa [2 ]
Uchimoto, Yuka [1 ]
Matsuda, Nobuhiko [1 ]
Takagawa, Naoko [1 ]
Takeshita, Ami [1 ]
Iwamoto, Yuri [1 ]
Okahata, Ryoko [1 ]
Tsujimoto, Tomomi [1 ]
Kreiborg, Sven [3 ,4 ,5 ]
Mallya, Sanjay M. [6 ]
Yang, Fan-pei Gloria [1 ,7 ,8 ]
机构
[1] Osaka Univ, Grad Sch Dent, Dept Oral & Maxillofacial Radiol, 1-8 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Taibah Univ, Coll Dent, Dept Oral & Maxillofacial Diagnost Sci, Div Oral Radiol, POB 2898, Madinah 43353, Saudi Arabia
[3] Univ Copenhagen, Fac Hlth & Med Sci, Sch Dent, Dept Pediat Dent & Clin Genet, Norre 20, DK-2200 Copenhagen, Denmark
[4] Univ Copenhagen, Dept Appl Math & Comp Sci, Sch Dent, 3D Craniofacial Image Res Lab, Norre 20, DK-2200 Copenhagen, Denmark
[5] Tech Univ Denmark, Copenhagen Univ Hosp, Rigshosp, Ctr Head & Orthoped, Norre 20, DK-2200 Copenhagen, Denmark
[6] UCLA Sch Dent, Sect Oral & Maxillofacial Radiol, 10833 Conte Ave, Los Angeles, CA 90095 USA
[7] Natl Tsing Hua Univ, Dept Foreign Languages & Literature, 101,Sect 2,Guangfu Rd, Hsinchu 300013, Taiwan
[8] Natl Tsing Hua Univ, Ctr Cognit & Mind Sci, 101,Sect 2,Guangfu Rd, Hsinchu 300013, Taiwan
关键词
MRI; Metallic materials; Image uniformity; Quantitative study; COIL;
D O I
10.1007/s11282-024-00778-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo assess quantitatively the effect of metallic materials on MR image uniformity using a standardized method.MethodsSix types of 1 cm cubic metallic materials (i.e., Au, Ag, Al, Au-Ag-Pd alloy, Ti, and Co-Cr alloy) embedded in a glass phantom filled were examined and compared with no metal condition inserted as a reference. The phantom was scanned five times under each condition using a 1.5-T MR superconducting magnet scanner with an 8-channel phased-array brain coil and head and neck coil. For each examination, the phantom was scanned in three planes: axial, coronal, and sagittal using T1-weighted spin echo (SE) and gradient echo (GRE) sequences in accordance with the American Society for Testing and Materials (ASTM) F2119-07 standard. Image uniformity was assessed using the non-uniformity index (NUI), which was developed by the National Electrical Manufacturers Association (NEMA), as an appropriate standardized measure for investigating magnetic field uniformity.ResultsT1-GRE images with Co-Cr typically elicited the lowest uniformity, followed by T1-GRE images with Ti, while all other metallic materials did not affect image uniformity. In particular, T1-GRE images with Co-Cr showed significantly higher NUI values as far as 6.6 cm at maximum equivalent to 11 slices centering around it in comparison with the measurement uncertainty from images without metallic materials.ConclusionWe found that MR image uniformity was influenced by the scanning sequence and coil type when Co-Cr and Ti were present. It is assumed that the image non-uniformity in Co-Cr and Ti is caused by their high magnetic susceptibility.
引用
收藏
页码:78 / 87
页数:10
相关论文
共 50 条
  • [31] Numerical and experimental study on improving temperature uniformity of solar furnaces for materials processing
    Li, B.
    Oliveira, F. A. C.
    Rodriguez, J.
    Fernandes, J. C.
    Rosa, L. G.
    SOLAR ENERGY, 2015, 115 : 95 - 108
  • [32] A retrospective magnetic resonance image study of patellar tendinosis
    Ashford, RL
    Cassella, JP
    McNamara, S
    Stevens, RM
    Turner, P
    PHYSICAL THERAPY IN SPORT, 2002, 3 (03) : 134 - 142
  • [33] Reduction of artifact of metallic implant in magnetic resonance imaging by combining paramagnetic and diamagnetic materials
    Gao, Yanhui
    Muramatsu, Kazuhiro
    Kushibe, Atsumichi
    Yamazaki, Keita
    Chiba, Akihiko
    Yamamoto, Toru
    JOURNAL OF APPLIED PHYSICS, 2010, 107 (09) : 936
  • [34] Nuclear magnetic resonance studies of metals in solid state non-metallic materials
    Srikanth, K
    Schurko, RW
    Hung, I
    Ramamoorthy, A
    MATERIALS SCIENCE AND TECHNOLOGY, 2003, 19 (09) : 1191 - 1196
  • [35] Partial volume effect in quantitative magnetic resonance perfusion imaging
    Chen, JJ
    Smith, MR
    Frayne, R
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1132 - 1135
  • [36] QUANTITATIVE MAGNETIC RESONANCE IMAGE ANALYSIS VIA THE EM ALGORITHM WITH STOCHASTIC VARIATION
    Zhang, Xiaoxi
    Johnson, Timothy D.
    Little, Roderick J. A.
    Cao, Yue
    ANNALS OF APPLIED STATISTICS, 2008, 2 (02): : 736 - 755
  • [37] Nuclear Magnetic Resonance Study of Nanoscale Ionic Materials
    Oommen, Joanna Mary
    Hussain, Muhammad Mustafa
    Emwas, Abdul-Hamid M.
    Agarwal, Praveen
    Archer, Lynden A.
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2010, 13 (11) : K87 - K88
  • [38] Quantitative Magnetic Resonance Imaging for Biological Image-Guided Adaptive Radiotherapy
    van Houdt, Petra J.
    Yang, Yingli
    van der Heide, Uulke A.
    FRONTIERS IN ONCOLOGY, 2021, 10
  • [39] The effect of obesity on regadenoson-induced myocardial hyperemia: a quantitative magnetic resonance imaging study
    DiBella, Edward V. R.
    Fluckiger, Jacob U.
    Chen, Liyong
    Kim, Tae Ho
    Pack, Nathan A.
    Matthews, Brian
    Adluru, Ganesh
    Priester, Tiffany
    Kuppahally, Suman
    Jiji, Ronny
    McGann, Chris
    Litwin, Sheldon E.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1435 - 1444
  • [40] The effect of obesity on regadenoson-induced myocardial hyperemia: a quantitative magnetic resonance imaging study
    Edward V. R. DiBella
    Jacob U. Fluckiger
    Liyong Chen
    Tae Ho Kim
    Nathan A. Pack
    Brian Matthews
    Ganesh Adluru
    Tiffany Priester
    Suman Kuppahally
    Ronny Jiji
    Chris McGann
    Sheldon E. Litwin
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1435 - 1444