Effect of metallic materials on magnetic resonance image uniformity: a quantitative experimental study

被引:0
|
作者
Shimamoto, Hiroaki [1 ]
Felemban, Doaa [2 ]
Uchimoto, Yuka [1 ]
Matsuda, Nobuhiko [1 ]
Takagawa, Naoko [1 ]
Takeshita, Ami [1 ]
Iwamoto, Yuri [1 ]
Okahata, Ryoko [1 ]
Tsujimoto, Tomomi [1 ]
Kreiborg, Sven [3 ,4 ,5 ]
Mallya, Sanjay M. [6 ]
Yang, Fan-pei Gloria [1 ,7 ,8 ]
机构
[1] Osaka Univ, Grad Sch Dent, Dept Oral & Maxillofacial Radiol, 1-8 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Taibah Univ, Coll Dent, Dept Oral & Maxillofacial Diagnost Sci, Div Oral Radiol, POB 2898, Madinah 43353, Saudi Arabia
[3] Univ Copenhagen, Fac Hlth & Med Sci, Sch Dent, Dept Pediat Dent & Clin Genet, Norre 20, DK-2200 Copenhagen, Denmark
[4] Univ Copenhagen, Dept Appl Math & Comp Sci, Sch Dent, 3D Craniofacial Image Res Lab, Norre 20, DK-2200 Copenhagen, Denmark
[5] Tech Univ Denmark, Copenhagen Univ Hosp, Rigshosp, Ctr Head & Orthoped, Norre 20, DK-2200 Copenhagen, Denmark
[6] UCLA Sch Dent, Sect Oral & Maxillofacial Radiol, 10833 Conte Ave, Los Angeles, CA 90095 USA
[7] Natl Tsing Hua Univ, Dept Foreign Languages & Literature, 101,Sect 2,Guangfu Rd, Hsinchu 300013, Taiwan
[8] Natl Tsing Hua Univ, Ctr Cognit & Mind Sci, 101,Sect 2,Guangfu Rd, Hsinchu 300013, Taiwan
关键词
MRI; Metallic materials; Image uniformity; Quantitative study; COIL;
D O I
10.1007/s11282-024-00778-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo assess quantitatively the effect of metallic materials on MR image uniformity using a standardized method.MethodsSix types of 1 cm cubic metallic materials (i.e., Au, Ag, Al, Au-Ag-Pd alloy, Ti, and Co-Cr alloy) embedded in a glass phantom filled were examined and compared with no metal condition inserted as a reference. The phantom was scanned five times under each condition using a 1.5-T MR superconducting magnet scanner with an 8-channel phased-array brain coil and head and neck coil. For each examination, the phantom was scanned in three planes: axial, coronal, and sagittal using T1-weighted spin echo (SE) and gradient echo (GRE) sequences in accordance with the American Society for Testing and Materials (ASTM) F2119-07 standard. Image uniformity was assessed using the non-uniformity index (NUI), which was developed by the National Electrical Manufacturers Association (NEMA), as an appropriate standardized measure for investigating magnetic field uniformity.ResultsT1-GRE images with Co-Cr typically elicited the lowest uniformity, followed by T1-GRE images with Ti, while all other metallic materials did not affect image uniformity. In particular, T1-GRE images with Co-Cr showed significantly higher NUI values as far as 6.6 cm at maximum equivalent to 11 slices centering around it in comparison with the measurement uncertainty from images without metallic materials.ConclusionWe found that MR image uniformity was influenced by the scanning sequence and coil type when Co-Cr and Ti were present. It is assumed that the image non-uniformity in Co-Cr and Ti is caused by their high magnetic susceptibility.
引用
收藏
页码:78 / 87
页数:10
相关论文
共 50 条
  • [21] Effect of Magnetic Resonance Image Quality on Structural and Functional Brain Connectivity: The Maastricht Study
    de Jong, Joost J. A.
    Jansen, Jacobus F. A.
    Vergoossen, Laura W. M.
    Schram, Miranda T.
    Stehouwer, Coen D. A.
    Wildberger, Joachim E.
    Linden, David E. J.
    Backes, Walter H.
    BRAIN SCIENCES, 2024, 14 (01)
  • [22] Experimental study of ESD effect on metallic enclosure
    Chan, KH
    Fung, LC
    Leung, SW
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 490 - 492
  • [23] THE CHARACTERIZATION OF EXPERIMENTAL GLIOSIS BY QUANTITATIVE NUCLEAR MAGNETIC-RESONANCE IMAGING
    BARNES, D
    MCDONALD, WI
    LANDON, DN
    JOHNSON, G
    BRAIN, 1988, 111 : 83 - 94
  • [24] Experimental study and analysis of microplastic behavior of microheterogeneous metallic materials
    Maire, E
    Lamagnere, P
    Lormand, G
    Fougeres, R
    Vincent, A
    JOURNAL DE PHYSIQUE IV, 1998, 8 (P4): : 139 - 144
  • [25] Mechanical behavior of metallic hollow sphere materials: Experimental study
    Gao, Z. Y.
    Yu, T. X.
    Zhao, H.
    JOURNAL OF AEROSPACE ENGINEERING, 2008, 21 (04) : 206 - 216
  • [26] Experimental study of tensile testing of metallic Materials in engineering mechanics
    Hashentuya
    PROCEEDINGS OF THE 2016 INTERNATIONAL FORUM ON MECHANICAL, CONTROL AND AUTOMATION (IFMCA 2016), 2017, 113 : 819 - 822
  • [27] EXPERIMENTAL-STUDY OF RESISTIVITY OF METALLIC MATERIALS WITH DYNAMIC DISORDER
    GANTMAKHER, VF
    KULESKO, GI
    TEPLINSKY, VM
    PRAMANA, 1987, 28 (05) : 594 - 594
  • [28] QUANTITATIVE STUDY OF THE GROWTH OF EXPERIMENTAL HEPATIC-TUMORS IN RATS BY USING MAGNETIC-RESONANCE-IMAGING
    QIN, YF
    VANCAUTEREN, M
    OSTEAUX, M
    WILLEMS, G
    INTERNATIONAL JOURNAL OF CANCER, 1992, 51 (04) : 665 - 670
  • [29] Mechanical behavior of metallic hollow sphere materials: Experimental study
    Gao, Z.Y.
    Yu, T.X.
    Zhao, H.
    Journal of Aerospace Engineering, 2008, 21 (04): : 206 - 216
  • [30] THE EFFECT OF METALLIC IMPLANTS ON MAGNETIC-RESONANCE-IMAGING - A BRIEF NOTE
    EBRAHEIM, NA
    COOMBS, RE
    JACKSON, WT
    ZEISS, J
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (09): : 1397 - 1398