Effect of metallic materials on magnetic resonance image uniformity: a quantitative experimental study

被引:0
|
作者
Shimamoto, Hiroaki [1 ]
Felemban, Doaa [2 ]
Uchimoto, Yuka [1 ]
Matsuda, Nobuhiko [1 ]
Takagawa, Naoko [1 ]
Takeshita, Ami [1 ]
Iwamoto, Yuri [1 ]
Okahata, Ryoko [1 ]
Tsujimoto, Tomomi [1 ]
Kreiborg, Sven [3 ,4 ,5 ]
Mallya, Sanjay M. [6 ]
Yang, Fan-pei Gloria [1 ,7 ,8 ]
机构
[1] Osaka Univ, Grad Sch Dent, Dept Oral & Maxillofacial Radiol, 1-8 Yamadaoka, Suita, Osaka 5650871, Japan
[2] Taibah Univ, Coll Dent, Dept Oral & Maxillofacial Diagnost Sci, Div Oral Radiol, POB 2898, Madinah 43353, Saudi Arabia
[3] Univ Copenhagen, Fac Hlth & Med Sci, Sch Dent, Dept Pediat Dent & Clin Genet, Norre 20, DK-2200 Copenhagen, Denmark
[4] Univ Copenhagen, Dept Appl Math & Comp Sci, Sch Dent, 3D Craniofacial Image Res Lab, Norre 20, DK-2200 Copenhagen, Denmark
[5] Tech Univ Denmark, Copenhagen Univ Hosp, Rigshosp, Ctr Head & Orthoped, Norre 20, DK-2200 Copenhagen, Denmark
[6] UCLA Sch Dent, Sect Oral & Maxillofacial Radiol, 10833 Conte Ave, Los Angeles, CA 90095 USA
[7] Natl Tsing Hua Univ, Dept Foreign Languages & Literature, 101,Sect 2,Guangfu Rd, Hsinchu 300013, Taiwan
[8] Natl Tsing Hua Univ, Ctr Cognit & Mind Sci, 101,Sect 2,Guangfu Rd, Hsinchu 300013, Taiwan
关键词
MRI; Metallic materials; Image uniformity; Quantitative study; COIL;
D O I
10.1007/s11282-024-00778-y
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo assess quantitatively the effect of metallic materials on MR image uniformity using a standardized method.MethodsSix types of 1 cm cubic metallic materials (i.e., Au, Ag, Al, Au-Ag-Pd alloy, Ti, and Co-Cr alloy) embedded in a glass phantom filled were examined and compared with no metal condition inserted as a reference. The phantom was scanned five times under each condition using a 1.5-T MR superconducting magnet scanner with an 8-channel phased-array brain coil and head and neck coil. For each examination, the phantom was scanned in three planes: axial, coronal, and sagittal using T1-weighted spin echo (SE) and gradient echo (GRE) sequences in accordance with the American Society for Testing and Materials (ASTM) F2119-07 standard. Image uniformity was assessed using the non-uniformity index (NUI), which was developed by the National Electrical Manufacturers Association (NEMA), as an appropriate standardized measure for investigating magnetic field uniformity.ResultsT1-GRE images with Co-Cr typically elicited the lowest uniformity, followed by T1-GRE images with Ti, while all other metallic materials did not affect image uniformity. In particular, T1-GRE images with Co-Cr showed significantly higher NUI values as far as 6.6 cm at maximum equivalent to 11 slices centering around it in comparison with the measurement uncertainty from images without metallic materials.ConclusionWe found that MR image uniformity was influenced by the scanning sequence and coil type when Co-Cr and Ti were present. It is assumed that the image non-uniformity in Co-Cr and Ti is caused by their high magnetic susceptibility.
引用
收藏
页码:78 / 87
页数:10
相关论文
共 50 条
  • [11] Experimental study on the evolution of necking zones of metallic materials
    Versaillot, Pierre Darry
    Wu, Yu-Fei
    Zhao, Zi-Long
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 189
  • [12] Multiparametric magnetic resonance imaging of experimental chronic kidney disease: A quantitative correlation study with histology
    Schley, Gunnar
    Jordan, Jutta
    Ellmann, Stephan
    Rosen, Seymour
    Eckardt, Kai-Uwe
    Uder, Michael
    Willam, Carsten
    Baeuerle, Tobias
    PLOS ONE, 2018, 13 (07):
  • [13] Evaluation of the impact of magnetic field homogeneity on image quality in magnetic resonance imaging: a baseline quantitative study at 1.5 T
    Manson, Eric Naab
    Mumuni, Abdul Nashirudeen
    Inkoom, Stephen
    Shirazu, Issahaku
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [14] Evaluation of the impact of magnetic field homogeneity on image quality in magnetic resonance imaging: a baseline quantitative study at 1.5 T
    Eric Naab Manson
    Abdul Nashirudeen Mumuni
    Stephen Inkoom
    Issahaku Shirazu
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [15] Effect of magnetic field profile on the uniformity of a distributed electron cyclotron resonance plasma
    Huang, C. C.
    Chou, S. F.
    Chang, T. H.
    Chao, H. W.
    Chen, C. C.
    PHYSICS OF PLASMAS, 2013, 20 (07)
  • [16] THE STUDY OF POLYMERIC MATERIALS BY NUCLEAR MAGNETIC RESONANCE
    POWLES, JG
    POLYMER, 1960, 1 (02) : 219 - 265
  • [17] Software Design for Quantitative Analysis of Myocardial Perfusion Magnetic Resonance Image
    Yu, Lin
    Huang, Siyi
    Ma, Meng
    Yang, Xin
    Pan, Jinwei
    Wei, Men
    2013 INTERNATIONAL CONFERENCE ON CYBER SCIENCE AND ENGINEERING (CYBERSE 2013), 2013, : 85 - 90
  • [18] Development of nuclear magnetic resonance as a tool of quantitative analysis for organic materials
    Saito, Takeshi
    Yamazaki, Taichi
    Numata, Masahiko
    METROLOGIA, 2019, 56 (05)
  • [19] Experimental Study on Magnetic Particle Grinding Uniformity Based on Hilbert Curve
    Zhang Z.-P.
    Chen Y.
    Pan M.-S.
    Wu X.-X.
    Gao H.-M.
    Surface Technology, 2022, 51 (08): : 408 - 417
  • [20] A quantitative study of intracranial hypotensive syndrome by magnetic resonance
    Tian, Weizhong
    Zhang, Ji
    Chen, Jinhua
    Liu, Ying
    Chen, Xiaoyun
    Wang, Ning
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2016, 141 : 71 - 76