Study of trapping levels in doped HgI2 radiation detectors

被引:0
|
作者
Sandia Natl Lab, Livermore, United States [1 ]
机构
来源
关键词
Alpha particles - Butane - Charge carriers - Crystal defects - Crystal impurities - Crystal lattices - Deep level transient spectroscopy - Mercury compounds - Naphthalene - Paraffins - Polyethylene glycols - Polyethylenes;
D O I
暂无
中图分类号
学科分类号
摘要
The transient charge technique, TCT, was used to measure the trapping levels of pure and doped HgI2 detectors over the temperature range of 170-300 K. The dopants were excess of Hg and I2, naphthalene, butane, heavy paraffins, polyethylene and polyethylene glycol. The charge carriers were induced by α particles as well as by a UV nitrogen (337 nm) pulsed laser beam. The TCT determined trapping levels are compared with levels reported in literature from other solid state measurements.
引用
收藏
相关论文
共 50 条
  • [31] CARRIER SURFACE RECOMBINATION IN HGI2 NUCLEAR-DETECTORS
    LEVI, A
    BURSHTEIN, Z
    SCHIEBER, M
    VACUUM, 1983, 33 (04) : 249 - 249
  • [32] PERSPECTIVES FOR THE USE OF HGI2 DETECTORS FOR THE PURPOSES OF THE FON EXPERIMENT
    FILIPOV, L
    SARIISKY, T
    DOKLADI NA BOLGARSKATA AKADEMIYA NA NAUKITE, 1988, 41 (05): : 79 - 81
  • [33] EVAPORATIVE DEGRADATION OF HGI2 X-RAY DETECTORS
    SCOTT, RS
    FREDERICKS, GE
    APPLIED PHYSICS LETTERS, 1975, 27 (02) : 99 - 100
  • [34] RECENT ADVANCES WITH HGI2 X-RAY DETECTORS
    SWIERKOW.SP
    ARMANTRO.GA
    WICHNER, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1974, NS21 (01) : 302 - 304
  • [35] Room temperature HgI2 nuclear radiation detector
    李伟堂
    李正辉
    朱世富
    银淑君
    赵北君
    陈观雄
    彭秀峰
    何福庆
    龙先灌
    Nuclear Science and Techniques, 1996, (01) : 48 - 51
  • [36] ON THE STOICHIOMETRY OF HGI2
    DISHON, G
    SCHIEBER, M
    BENDOR, L
    HALITZ, L
    MATERIALS RESEARCH BULLETIN, 1981, 16 (05) : 565 - 574
  • [37] EXCITONS IN HGI2
    ANEDDA, A
    FORTIN, E
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1977, 84 (02): : K87 - K90
  • [38] DOSIMETRY WITH HGI2
    MANFREDOTTI, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (01): : 173 - 178
  • [39] X-RAY-FLUORESCENCE ESCAPE PEAKS IN HGI2 DETECTORS
    LIUXU, X
    HEITZ, C
    SIFFERT, P
    REGAL, R
    X-RAY SPECTROMETRY, 1994, 23 (04) : 178 - 182
  • [40] Array of HgI2 detectors on the HL-1M Tokamak
    Yang, JW
    Zhang, W
    Wang, SQ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (08): : 2513 - 2516