Study of trapping levels in doped HgI2 radiation detectors

被引:0
|
作者
Sandia Natl Lab, Livermore, United States [1 ]
机构
来源
关键词
Alpha particles - Butane - Charge carriers - Crystal defects - Crystal impurities - Crystal lattices - Deep level transient spectroscopy - Mercury compounds - Naphthalene - Paraffins - Polyethylene glycols - Polyethylenes;
D O I
暂无
中图分类号
学科分类号
摘要
The transient charge technique, TCT, was used to measure the trapping levels of pure and doped HgI2 detectors over the temperature range of 170-300 K. The dopants were excess of Hg and I2, naphthalene, butane, heavy paraffins, polyethylene and polyethylene glycol. The charge carriers were induced by α particles as well as by a UV nitrogen (337 nm) pulsed laser beam. The TCT determined trapping levels are compared with levels reported in literature from other solid state measurements.
引用
收藏
相关论文
共 50 条
  • [21] EVALUATION OF HGI2 DETECTORS FOR LEAD DETECTION IN PAINT
    WANG, YJ
    IWANCZYK, JS
    GRAHAM, WR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) : 846 - 850
  • [22] A PHOTODISSOCIATION STUDY OF HGI2
    JORDAN, KJ
    LIPSON, RH
    YANG, DS
    JOURNAL OF CHEMICAL PHYSICS, 1992, 97 (12): : 9099 - 9106
  • [23] HGI2 DETECTORS FROM SOLUTION GROWN CRYSTALS
    FRIANT, A
    MELLET, J
    SALIOU, C
    BRAHIM, TM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) : 281 - 285
  • [24] DEVELOPMENT OF HGI2 DETECTORS AS DOSIMETER FOR INTERSTITIAL TREATMENTS
    LOEWENTHAL, E
    LOEWINGER, E
    FUKS, Z
    CAINE, S
    HOLZER, A
    SHIEBER, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 770 - 770
  • [25] Purification of HgI2 Crystals from Physical Vapor Transport for Application as Radiation Detectors
    Trencher Martins, Joao F.
    dos Santos, Robinson A.
    da Costa, Fabio E.
    de Mesquita, Carlos H.
    Hamada, Margarida M.
    ADVANCED MATERIALS AND INFORMATION TECHNOLOGY PROCESSING II, 2012, 586 : 156 - 160
  • [26] USE OF THICK HGI2 DETECTORS AS INTELLIGENT SPECTROMETERS
    OLMOS, P
    GARCIABELMONTE, G
    PEREZ, JM
    DIAZ, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 45 - 50
  • [27] DEFECT LEVELS IN HGI2 AND ILLUMINATION EFFECT
    MOHAMMEDBRAHIM, T
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1981, 65 (01): : K1 - K6
  • [28] HOLE TRAPPING AND INFRARED QUENCHING OF PHOTOCONDUCTIVITY IN HGI2 CRYSTALS
    SAURA, J
    TOGNETTI, NP
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1975, 31 (02): : K125 - K128
  • [29] Digital pulse height correction in HgI2 γ-ray detectors
    Chaudhuri, S. K.
    Lohstroh, A.
    Nakhostin, M.
    Sellin, P. J.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [30] CHARACTERIZATION EFFORT OF HGI2 RADIATION DETECTORS BY PULSED LASER TRANSIENT CHARGE INJECTION TECHNIQUE
    CHO, ZH
    WATT, MK
    SLAPA, M
    TOVE, PA
    SCHIEBER, M
    DAVIES, T
    SCHNEPPLE, W
    RANDTKE, P
    CARLSTON, R
    SARID, D
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 229 - 240