Study of trapping levels in doped HgI2 radiation detectors

被引:0
|
作者
Sandia Natl Lab, Livermore, United States [1 ]
机构
来源
关键词
Alpha particles - Butane - Charge carriers - Crystal defects - Crystal impurities - Crystal lattices - Deep level transient spectroscopy - Mercury compounds - Naphthalene - Paraffins - Polyethylene glycols - Polyethylenes;
D O I
暂无
中图分类号
学科分类号
摘要
The transient charge technique, TCT, was used to measure the trapping levels of pure and doped HgI2 detectors over the temperature range of 170-300 K. The dopants were excess of Hg and I2, naphthalene, butane, heavy paraffins, polyethylene and polyethylene glycol. The charge carriers were induced by α particles as well as by a UV nitrogen (337 nm) pulsed laser beam. The TCT determined trapping levels are compared with levels reported in literature from other solid state measurements.
引用
收藏
相关论文
共 50 条
  • [11] THE EFFECT OF CHARGE TRAPPING ON THE SPECTROMETRIC PERFORMANCE OF HGI2 GAMMA-RAY DETECTORS
    IWANCZYK, JS
    SCHNEPPLE, WF
    MASTERSON, MJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03): : 421 - 426
  • [12] A comparative study on the performance of radiation detectors from the HgI2 crystals grown by different techniques
    Martins, Joao F. T.
    Costa, Fabio E.
    dos Santos, Robinson A.
    de Mesquita, Carlos H.
    Hamada, Margarida M.
    NUKLEONIKA, 2012, 57 (04) : 555 - 562
  • [13] Heat treating and detectors characterization of α-HgI2
    Xu, Gang
    Jie, Wanqi
    Li, Gaohong
    Sun, Xiaoyan
    Xiyou Jinshu Cailiao Yu Gongcheng/Rare Metal Materials and Engineering, 2010, 39 (12): : 20 - 22
  • [14] Radiometric and dosimetric characteristics of HgI2 detectors
    Zaletin, V.M.
    Krivozubov, O.V.
    Torlin, M.A.
    Fomin, V.I.
    Soviet atomic energy, 1988, 63 (04): : 797 - 801
  • [15] RADIOMETRIC AND DOSIMETRIC CHARACTERISTICS OF HGI2 DETECTORS
    ZALETIN, VM
    KRIVOZUBOV, OV
    TORLIN, MA
    FOMIN, VI
    SOVIET ATOMIC ENERGY, 1987, 63 (04): : 797 - 801
  • [16] Spectroscopic performance of thick HgI2 detectors
    Meng, L. J.
    He, Z.
    Alexander, B.
    Sandoval, J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 1706 - 1712
  • [17] Heat Treating and Detectors Characterization of α-HgI2
    Xu Gang
    Jie Wanqi
    Li Gaohong
    Sun Xiaoyan
    RARE METAL MATERIALS AND ENGINEERING, 2010, 39 (12) : 2088 - 2090
  • [18] STABILIZATION OF HGI2 X-RAY-DETECTORS
    SQUILLANTE, MR
    SHAH, KS
    MOY, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01): : 79 - 81
  • [19] COMPARISON OF THE EFFICIENCY VALUES OF HGI2 AND NAI DETECTORS
    RIEPPO, R
    NUCLEAR INSTRUMENTS & METHODS, 1981, 184 (2-3): : 599 - 601
  • [20] NOVEL PULSE PROCESSING SYSTEM FOR HGI2 DETECTORS
    KURZ, R
    NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (01): : 91 - 95