Wear of polyethylene cups in total hip arthroplasty: A parametric mathematical model

被引:0
|
作者
Pietrabissa, Riccardo [1 ]
Raimondi, Manuela [1 ]
Di Martino, Elena [1 ]
机构
[1] Dipartimento di Bioingegneria, Politecnico di Milano, Milano, Italy
来源
Medical Engineering and Physics | 1998年 / 20卷 / 03期
关键词
Mathematical models - Polyethylenes - Stress analysis - Surface roughness - Wear of materials;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The wear factor is taken from pin-on-disc wear tests as a function of materials and finishing of the articular joint. The forces acting on the hip joint are taken from experimental data found in the literature whilst the load distribution is calculated under the hypotheses of perfectly rigid ideal wear coupling. The sliding distance is obtained by combining the three elementary displacements - due to rotations around the three axes - at the generic bearing surface location. The simulations show that the polymeric wear volume per step cycle decreases ranging from fast walking speeds to low running speeds, it increases linearly with patient body weight and with femoral head diameter, it decreases slightly for positive variations of the socket inclination angle and it increases exponentially with femoral head roughness. The volumetric wear rate per year calculated for a standard reference patient is 5.8 mm3. The relevant iso-wear maps show a marginal pattern with the maximum located near the cup superior borderline. At the instant of peak load, the iso-stress maps show a paracentral pattern with the maximum superior to the cup polar point, and the iso-sliding distance maps show a marginal pattern with two maxima located near the cup's superior and inferior borderlines.
引用
收藏
页码:199 / 210
相关论文
共 50 条
  • [41] Digital edge-detection measurement of polyethylene wear after total hip arthroplasty
    Shaver, SM
    Brown, TD
    Hillis, SL
    Callaghan, JJ
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05): : 690 - 700
  • [42] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Jiri Gallo
    Vitezslav Havranek
    Jana Zapletalova
    International Orthopaedics, 2010, 34 : 19 - 26
  • [43] FEMORAL-HEAD TECHNOLOGIES TO REDUCE POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    CUCKLER, JM
    BEARCROFT, J
    ASGIAN, CM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 57 - 63
  • [44] Thirty-two millimetre heads and accelerated polyethylene wear in total hip arthroplasty
    Blom, A. W.
    Madhavan, P.
    Lee, M.
    Learmonth, I. D.
    HIP INTERNATIONAL, 2006, 16 (03) : 207 - 209
  • [45] Polyethylene wear In Total Hip Arthroplasty -matched pair analysis of ceramic and metal heads
    Ranawat, C. S.
    Rasquinha, V. J.
    Rodriguez, J. A.
    BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 59 - 59
  • [46] Late dislocations after cementless total hip arthroplasty resulting from polyethylene wear
    Orozco, F
    Hozack, WJ
    JOURNAL OF ARTHROPLASTY, 2000, 15 (08): : 1059 - 1063
  • [47] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Gallo, Jiri
    Havranek, Vitezslav
    Zapletalova, Jana
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (01) : 19 - 26
  • [48] Dual Mobility Cups as the Routine Choice in Total Hip Arthroplasty
    Aguado-Maestro, Ignacio
    de Blas-Sanz, Ines
    Elena Sanz-Penas, Ana
    Virginia Campesino-Nieto, Silvia
    Diez-Rodriguez, Jesus
    Valle-Lopez, Sergio
    Espinel-Riol, Alberto
    Fernandez-Diez, Diego
    Garcia-Alonso, Manuel
    MEDICINA-LITHUANIA, 2022, 58 (04):
  • [49] Dual-Mobility Cups in Primary Total Hip Arthroplasty
    Bellova, Petri
    Goronzy, Jens
    Riedel, Roman
    Grothe, Tim
    Hartmann, Albrecht
    Guenther, Klaus-Peter
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2023, 161 (01): : 74 - 84
  • [50] Dual mobility cups for total hip arthroplasty: tips and tricks
    Neri, Thomas
    Boyer, Bertrand
    Batailler, Cecile
    Klasan, Antonio
    Lustig, Sebastien
    Philippot, Remi
    Farizon, Frederic
    SICOT-J, 2020, 6