Wear of polyethylene cups in total hip arthroplasty: A parametric mathematical model

被引:0
|
作者
Pietrabissa, Riccardo [1 ]
Raimondi, Manuela [1 ]
Di Martino, Elena [1 ]
机构
[1] Dipartimento di Bioingegneria, Politecnico di Milano, Milano, Italy
来源
Medical Engineering and Physics | 1998年 / 20卷 / 03期
关键词
Mathematical models - Polyethylenes - Stress analysis - Surface roughness - Wear of materials;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The wear factor is taken from pin-on-disc wear tests as a function of materials and finishing of the articular joint. The forces acting on the hip joint are taken from experimental data found in the literature whilst the load distribution is calculated under the hypotheses of perfectly rigid ideal wear coupling. The sliding distance is obtained by combining the three elementary displacements - due to rotations around the three axes - at the generic bearing surface location. The simulations show that the polymeric wear volume per step cycle decreases ranging from fast walking speeds to low running speeds, it increases linearly with patient body weight and with femoral head diameter, it decreases slightly for positive variations of the socket inclination angle and it increases exponentially with femoral head roughness. The volumetric wear rate per year calculated for a standard reference patient is 5.8 mm3. The relevant iso-wear maps show a marginal pattern with the maximum located near the cup superior borderline. At the instant of peak load, the iso-stress maps show a paracentral pattern with the maximum superior to the cup polar point, and the iso-sliding distance maps show a marginal pattern with two maxima located near the cup's superior and inferior borderlines.
引用
收藏
页码:199 / 210
相关论文
共 50 条
  • [21] Highly Crosslinked Polyethylene Reduces Wear in Total Hip Arthroplasty at 5 Years
    Mutimer, Jonathan
    Devane, Peter A.
    Adams, Kathryn
    Horne, J. Geoffrey
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (12) : 3228 - 3233
  • [22] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Delank, Karl-Stefan
    Drees, Philipp
    Menzel, Nicole
    Hansen, Torsten
    Duschner, Heinz
    Eckardt, Anke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (08) : 509 - 516
  • [23] Degree of the Polyethylene Component Wear - a Predictive Factor for the Outcome of Total Hip Arthroplasty
    Radulescu, Radu
    Badila, Adrian
    Manolescu, Robert
    Japie, Ioan
    Badila, Elisabeta
    Bolocan, Alexandra
    Paduraru, Dan Nicolae
    MATERIALE PLASTICE, 2013, 50 (03) : 212 - 214
  • [24] A thigh mass resulting from polyethylene wear of a revision total hip arthroplasty
    Lachiewicz, Paul F.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (455) : 274 - 276
  • [25] Uncemented Jumbo Cups for Revision Total Hip Arthroplasty
    von Roth, Philipp
    Abdel, Matthew P.
    Harmsen, W. Scott
    Berry, Daniel J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2015, 97A (04): : 284 - 287
  • [26] Polyethylene wear and synovitis in total hip arthroplasty -: A sonographic study of 48 hips
    Kesteris, U
    Jonsson, K
    Robertsson, O
    Önnerfält, R
    Wingstrand, H
    JOURNAL OF ARTHROPLASTY, 1999, 14 (02): : 138 - 143
  • [27] Dual mobility cups in revision total hip arthroplasty
    Viste, Anthony
    Desmarchelier, Romain
    Fessy, Michel-Henri
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 535 - 542
  • [28] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Karl-Stefan Delank
    Philipp Drees
    Nicole Menzel
    Torsten Hansen
    Heinz Duschner
    Anke Eckardt
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 509 - 516
  • [29] Polyethylene wear against alumina and zirconia heads in cemented total hip arthroplasty
    Liang, Bojian
    Kawanabe, Keiichi
    Ise, Kentaro
    Iida, Hirokazu
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2007, 22 (02): : 251 - 257
  • [30] Measurement of polyethylene wear in total hip arthroplasty - Accuracy versus ease of use
    Kang, JS
    Park, SR
    Ebramzadeh, E
    Dorr, LD
    YONSEI MEDICAL JOURNAL, 2003, 44 (03) : 473 - 478