Highly Crosslinked Polyethylene Reduces Wear in Total Hip Arthroplasty at 5 Years

被引:55
|
作者
Mutimer, Jonathan [1 ,2 ]
Devane, Peter A. [2 ]
Adams, Kathryn [2 ]
Horne, J. Geoffrey [2 ]
机构
[1] Cheltenham Gen Hosp, Cheltenham GL53 7AN, Glos, England
[2] Wellington Sch Med, Dept Surg, Div Orthoped Surg, Wellington, New Zealand
关键词
DEBRIS-INDUCED OSTEOLYSIS; FOLLOW-UP; ACETABULAR CUPS; RADIOSTEREOMETRIC ANALYSIS; PELVIC OSTEOLYSIS; PENETRATION RATE; CONTROLLED-TRIAL; REPLACEMENT; MARATHON; OUTCOMES;
D O I
10.1007/s11999-010-1379-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Although hip arthroplasty reliably relieves pain and improves function, problems have arisen with wear and osteolysis. Highly crosslinked polyethylene has been developed to address this problem although at present there is limited clinical evidence it does so longer term. Questions/purposes We compared the in vivo wear of standard versus highly crosslinked polyethylene (HXLP) in primary total hip arthroplasty at a minimum of 5-year followup. Methods We enrolled 122 patients in a prospective, double-blinded, randomized trial and followed them annually to assess their progress. Annual radiographs were analyzed using previously validated edge detection software to assess for two-dimensional, three-dimensional, and volumetric wear. The mean follow up was 5.5 years (range, 4.1 to 7 years). Results The two-dimensional wear measurements for HXLP showed lower wear compared to the conventional group (0.05 mm/year versus 0.26 mm/year, respectively). Three-dimensional and volumetric wear were similarly lower in the HXLP group. Conclusions Highly crosslinked polyethylene undergoes substantially less wear than conventional polyethylene at medium term. The effect of hip arthroplasty longevity will need to be assessed with longer-term studies, but this may lead to a decreased need for revision as a result of less wear and osteolysis.
引用
收藏
页码:3228 / 3233
页数:6
相关论文
共 50 条
  • [1] Wear particle analysis of highly crosslinked polyethylene isolated from a failed total hip arthroplasty
    Minoda, Yukihide
    Kobayashi, Akio
    Sakawa, Akira
    Aihara, Masaharu
    Tada, Koichi
    Sugama, Ryo
    Iwakiri, Kentaro
    Ohashi, Hirotsugu
    Takaoka, Kunio
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2008, 86B (02) : 501 - 505
  • [2] In vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases
    Hata, Kanako
    Minoda, Yukihide
    Ikebuchi, Mitsuhiko
    Mizokawa, Shigekazu
    Ohta, Yoichi
    Miyazaki, Nobuyuki
    Miyake, Yusuke
    Nakamura, Hiroaki
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (03)
  • [3] In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty
    Matsuoka, Tsunehiro
    Takahashi, Yasuhito
    Ishida, Tsunehito
    Tateiwa, Toshiyuki
    Shishido, Takaaki
    Yamamoto, Kengo
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7195 - 7203
  • [4] In vivo creep and wear performance of vitamin-E-diffused highly crosslinked polyethylene in total hip arthroplasty
    Tsunehiro Matsuoka
    Yasuhito Takahashi
    Tsunehito Ishida
    Toshiyuki Tateiwa
    Takaaki Shishido
    Kengo Yamamoto
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7195 - 7203
  • [5] In vivo wear particles of remelted highly crosslinked polyethylene after total hip arthroplasty: report of four cases
    Kanako Hata
    Yukihide Minoda
    Mitsuhiko Ikebuchi
    Shigekazu Mizokawa
    Yoichi Ohta
    Nobuyuki Miyazaki
    Yusuke Miyake
    Hiroaki Nakamura
    [J]. Journal of Materials Science: Materials in Medicine, 2015, 26
  • [6] Primary Total Hip Arthroplasty in Patients Less Than 50 Years of Age at a Mean of 16 Years: Highly Crosslinked Polyethylene Significantly Reduces the Risk of Revision
    Bryan, Andrew J.
    Calkins, Tyler E.
    Karas, Vasili
    Culvern, Chris
    Nam, Denis
    Della Valle, Craig J.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (07): : S238 - S241
  • [7] Clinical Performance of a Highly Crosslinked Polyethylene at Four to Five Years In Total Hip Arthroplasty: A Randomized Prospective Trial
    Martell, J. M.
    Verner, J. J.
    Incavo, S. J.
    [J]. BIOCERAMICS AND ALTERNATIVE BEARINGS IN JOINT ARTHROPLASTY, 2005, : 49 - 49
  • [8] POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    BANKSTON, AB
    CATES, H
    RITTER, MA
    KEATING, EM
    FARIS, PM
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 7 - 13
  • [9] Recent update on crosslinked polyethylene in total hip arthroplasty
    Langlois, Jean
    Hamadouche, Moussa
    [J]. SICOT-J, 2020, 6
  • [10] Retrieval Analysis of Sequentially Annealed Highly Crosslinked Polyethylene Used in Total Hip Arthroplasty
    Kurtz, Steven M.
    MacDonald, Daniel W.
    Mont, Michael A.
    Parvizi, Javad
    Malkani, Arthur L.
    Hozack, William
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (03) : 962 - 971