Highly Crosslinked Polyethylene Reduces Wear in Total Hip Arthroplasty at 5 Years

被引:55
|
作者
Mutimer, Jonathan [1 ,2 ]
Devane, Peter A. [2 ]
Adams, Kathryn [2 ]
Horne, J. Geoffrey [2 ]
机构
[1] Cheltenham Gen Hosp, Cheltenham GL53 7AN, Glos, England
[2] Wellington Sch Med, Dept Surg, Div Orthoped Surg, Wellington, New Zealand
关键词
DEBRIS-INDUCED OSTEOLYSIS; FOLLOW-UP; ACETABULAR CUPS; RADIOSTEREOMETRIC ANALYSIS; PELVIC OSTEOLYSIS; PENETRATION RATE; CONTROLLED-TRIAL; REPLACEMENT; MARATHON; OUTCOMES;
D O I
10.1007/s11999-010-1379-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Although hip arthroplasty reliably relieves pain and improves function, problems have arisen with wear and osteolysis. Highly crosslinked polyethylene has been developed to address this problem although at present there is limited clinical evidence it does so longer term. Questions/purposes We compared the in vivo wear of standard versus highly crosslinked polyethylene (HXLP) in primary total hip arthroplasty at a minimum of 5-year followup. Methods We enrolled 122 patients in a prospective, double-blinded, randomized trial and followed them annually to assess their progress. Annual radiographs were analyzed using previously validated edge detection software to assess for two-dimensional, three-dimensional, and volumetric wear. The mean follow up was 5.5 years (range, 4.1 to 7 years). Results The two-dimensional wear measurements for HXLP showed lower wear compared to the conventional group (0.05 mm/year versus 0.26 mm/year, respectively). Three-dimensional and volumetric wear were similarly lower in the HXLP group. Conclusions Highly crosslinked polyethylene undergoes substantially less wear than conventional polyethylene at medium term. The effect of hip arthroplasty longevity will need to be assessed with longer-term studies, but this may lead to a decreased need for revision as a result of less wear and osteolysis.
引用
收藏
页码:3228 / 3233
页数:6
相关论文
共 50 条
  • [31] The effect of total hip arthroplasty cup design on polyethylene wear rate
    Hamilton, WG
    Hopper, RH
    Ginn, SD
    Hammell, NP
    Engh, CA
    Engh, CA
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 63 - 72
  • [32] THE ORIGIN OF SUBMICRON POLYETHYLENE WEAR DEBRIS IN TOTAL HIP-ARTHROPLASTY
    MCKELLOP, HA
    CAMPBELL, P
    PARK, SH
    SCHMALZRIED, TP
    GRIGORIS, P
    AMSTUTZ, HC
    SARMIENTO, A
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (311) : 3 - 20
  • [33] Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    Young, AM
    Sychterz, CJ
    Hopper, RH
    Engh, CA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 58 - 63
  • [34] In vivo and ex vivo measurement of polyethylene wear in total hip arthroplasty
    Goldvasser, Dov
    Hansen, Viktor J.
    Noz, Marilyn E.
    Maguire, Gerald Q., Jr.
    Zeleznik, Michael P.
    Olivecrona, Henrik
    Bragdon, Charles R.
    Weidenhielm, Lars
    Malchau, Henrik
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (03) : 271 - 275
  • [35] In vivo wear of bilateral total hip replacements: conventional versus crosslinked polyethylene
    Heisel, C
    Silva, M
    Schmalzried, TP
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2005, 125 (08) : 555 - 557
  • [36] EXTERNAL WEAR OF THE POLYETHYLENE SOCKET IN CEMENTED TOTAL HIP-ARTHROPLASTY
    WROBLEWSKI, BM
    LYNCH, M
    ATKINSON, JR
    DOWSON, D
    ISAAC, GH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 61 - 63
  • [37] Ultra high molecular weight polyethylene wear in total hip arthroplasty
    Bosco, JA
    Ong, BC
    [J]. ORTHOPEDICS, 2000, 23 (05) : 499 - 503
  • [38] Influence of Pelvic Tilt on Polyethylene Wear after Total Hip Arthroplasty
    Tezuka, Taro
    Inaba, Yutaka
    Kobayashi, Naomi
    Ike, Hiroyuki
    Kubota, So
    Kawamura, Masaki
    Saito, Tomoyuki
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [39] In vivo wear of bilateral total hip replacements: conventional versus crosslinked polyethylene
    Christian Heisel
    Mauricio Silva
    Thomas P. Schmalzried
    [J]. Archives of Orthopaedic and Trauma Surgery, 2005, 125 : 555 - 557
  • [40] Cross-Linked Polyethylene for Total Hip Arthroplasty Markedly Reduces Revision Surgery at 16 Years
    de Steiger, R.
    Lorimer, M.
    Graves, S. E.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (15): : 1281 - 1288