Wear of polyethylene cups in total hip arthroplasty: A parametric mathematical model

被引:0
|
作者
Pietrabissa, Riccardo [1 ]
Raimondi, Manuela [1 ]
Di Martino, Elena [1 ]
机构
[1] Dipartimento di Bioingegneria, Politecnico di Milano, Milano, Italy
来源
Medical Engineering and Physics | 1998年 / 20卷 / 03期
关键词
Mathematical models - Polyethylenes - Stress analysis - Surface roughness - Wear of materials;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a parametric mathematical model of the head-cup wear coupling in total hip arthroplasty (THA). The model evaluates the dependence of acetabular volumetric wear upon the characteristic parameters of patient and hip prosthesis. Archard's law is assumed to calculate the wear coupling behaviour. The wear factor is taken from pin-on-disc wear tests as a function of materials and finishing of the articular joint. The forces acting on the hip joint are taken from experimental data found in the literature whilst the load distribution is calculated under the hypotheses of perfectly rigid ideal wear coupling. The sliding distance is obtained by combining the three elementary displacements - due to rotations around the three axes - at the generic bearing surface location. The simulations show that the polymeric wear volume per step cycle decreases ranging from fast walking speeds to low running speeds, it increases linearly with patient body weight and with femoral head diameter, it decreases slightly for positive variations of the socket inclination angle and it increases exponentially with femoral head roughness. The volumetric wear rate per year calculated for a standard reference patient is 5.8 mm3. The relevant iso-wear maps show a marginal pattern with the maximum located near the cup superior borderline. At the instant of peak load, the iso-stress maps show a paracentral pattern with the maximum superior to the cup polar point, and the iso-sliding distance maps show a marginal pattern with two maxima located near the cup's superior and inferior borderlines.
引用
收藏
页码:199 / 210
相关论文
共 50 条
  • [31] Pelvic mass caused by polyethylene wear after uncemented total hip arthroplasty
    Wang, JW
    Lin, CC
    JOURNAL OF ARTHROPLASTY, 1996, 11 (05): : 626 - 628
  • [32] Severe Polyethylene Wear Requiring Revision Total Hip Arthroplasty in Three Dogs
    Nesser, Valerie E.
    Kowaleski, Michael P.
    Boudrieau, Randy J.
    VETERINARY SURGERY, 2016, 45 (05) : 664 - 671
  • [33] Dual mobility cups in revision total hip arthroplasty
    Anthony Viste
    Romain Desmarchelier
    Michel-Henri Fessy
    International Orthopaedics, 2017, 41 : 535 - 542
  • [34] The Use of Jumbo Cups in Revision Total Hip Arthroplasty
    von Roth, Philipp
    Wassilew, Georgi I.
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2017, 155 (05): : 534 - 538
  • [35] Wear rate model for UHMWPE in total hip and knee arthroplasty
    Goswami, T.
    Alhassan, S.
    MATERIALS & DESIGN, 2008, 29 (02): : 289 - 296
  • [36] Influence of a foreign body on the wear of metallic femoral heads and polyethylene acetabular cups of total hip prostheses
    D. Najjar
    A. Behnamghader
    A. Iost
    H. Migaud
    Journal of Materials Science, 2000, 35 : 4583 - 4588
  • [37] Influence of a foreign body on the wear of metallic femoral heads and polyethylene acetabular cups of total hip prostheses
    Najjar, D
    Behnamghader, A
    Iost, A
    Migaud, H
    JOURNAL OF MATERIALS SCIENCE, 2000, 35 (18) : 4583 - 4588
  • [38] Do Monoblock Cups Improve Survivorship, Decrease Wear, or Reduce Osteolysis in Uncemented Total Hip Arthroplasty?
    Halma, Jelle J.
    Vogely, Charles
    Dhert, Wouter J.
    Van Gaalen, Steven M.
    de Gast, Arthur
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (11) : 3572 - 3580
  • [39] Creep and Wear in Vitamin E-Infused Highly Cross-Linked Polyethylene Cups for Total Hip Arthroplasty A Prospective Randomized Controlled Trial
    Rochcongar, G.
    Buia, G.
    Bourroux, E.
    Dunet, J.
    Chapus, V.
    Hulet, C.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2018, 100 (02): : 107 - 114
  • [40] Comparison of polyethylene wear against alumina and zirconia heads in cemented total hip arthroplasty
    Kawanabe, K.
    Liang, B.
    Ise, K.
    Nakamura, T.
    Bioceramics and Alternative Bearings in Joint Arthroplasty, 2007, : 83 - 87