Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty

被引:61
|
作者
Gallo, Jiri [1 ]
Havranek, Vitezslav [1 ]
Zapletalova, Jana
机构
[1] Palacky Univ, Joint Lab Opt, CR-77147 Olomouc, Czech Republic
关键词
ACETABULAR COMPONENT; FOLLOW-UP; CUP; ORIENTATION; PROSTHESIS; ABDUCTION; SURVIVAL; POSITION; 12-YEAR; PATIENT;
D O I
10.1007/s00264-009-0731-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We analysed data from 155 revisions of identical cementless hip prostheses to determine the influence of patient-, implant- and surgery-related factors on the polyethylene wear rate and size of periprosthetic osteolysis (OL). This was calculated by logistic regression analysis. Factors associated with an increased/decreased wear rate included position of the cup relative to Kohler's line, increase in abduction angle of the cup, traumatic and inflammatory arthritis as a primary diagnosis, and patient height. Severe acetabular bone defects were predicted by an increased wear rate (odds ratio, OR = 5.782 for wear rate above 200 mm(3)/y), and increased height of the patient (OR = 0.905 per each centimetre). Predictors of severe bone defects in the femur were the increased wear rate (OR = 3.479 for wear rate above 200 mm(3)/y) and placement of the cup outside of the true acetabulum (OR = 3.292). Variables related to surgical technique were the most predictive of polyethylene wear rate.
引用
收藏
页码:19 / 26
页数:8
相关论文
共 50 条
  • [1] Risk factors for accelerated polyethylene wear and osteolysis in ABG I total hip arthroplasty
    Jiri Gallo
    Vitezslav Havranek
    Jana Zapletalova
    International Orthopaedics, 2010, 34 : 19 - 26
  • [2] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Karl-Stefan Delank
    Philipp Drees
    Nicole Menzel
    Torsten Hansen
    Heinz Duschner
    Anke Eckardt
    Archives of Orthopaedic and Trauma Surgery, 2006, 126 : 509 - 516
  • [3] Increased polyethylene wear after cementless ABG I total hip arthroplasty
    Delank, Karl-Stefan
    Drees, Philipp
    Menzel, Nicole
    Hansen, Torsten
    Duschner, Heinz
    Eckardt, Anke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2006, 126 (08) : 509 - 516
  • [4] Effect of acetabular modularity on polyethylene wear and osteolysis in total hip arthroplasty
    Young, AM
    Sychterz, CJ
    Hopper, RH
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01): : 58 - 63
  • [5] Early polyethylene wear and osteolysis in cementless total hip arthroplasty - The influence of femoral head size and polyethylene thickness
    Lee, PC
    Shih, CH
    Chen, WJ
    Tu, YK
    Tai, CL
    JOURNAL OF ARTHROPLASTY, 1999, 14 (08): : 976 - 981
  • [6] Impact of Various Factors on the Polyethylene Wear Rate in Total Hip Arthroplasty
    Tikhilov, R. M.
    Shubnyakov, M. I.
    Boyarov, A. A.
    Denisov, A. O.
    Shubnyakov, I. I.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2018, 24 (01): : 18 - 28
  • [7] POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    BANKSTON, AB
    CATES, H
    RITTER, MA
    KEATING, EM
    FARIS, PM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 7 - 13
  • [8] Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    Sochart, DH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (363) : 135 - 150
  • [9] True wear rates as predictors of risk for osteolysis after total hip arthroplasty - Reply
    Dowd, JE
    Sychterz, CJ
    Young, AM
    Engh, CA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (08): : 1277 - 1277
  • [10] Polyethylene Wear Particle Induced Osteolysis in Total Hip Replacement
    Patil, Nilesh
    Jin, Wen-tao
    Mow, Christopher S.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2008, 2 (01) : 1 - 7