Study and development of multilayer needle-type enzyme-based glucose microsensors

被引:0
|
作者
Sternberg, R. [1 ]
Barrau, M.-B. [1 ]
Gangiotti, L. [1 ]
Thevenot, D.R. [1 ]
Bindra, D.S. [1 ]
Wilson, G.S. [1 ]
Velho, G. [1 ]
Froguel, P. [1 ]
Reach, G. [1 ]
机构
[1] Laboratoire de Bioelectrochimie et Analyse du Milieu, U.F.R. de Sciences et de Technologie, Universite Paris-Val de Marne, 94010 Creteil Cedex, France
关键词
Covalent Coupling - Glucose Microsensors - Needle Sensor - Subcutaneous Implant;
D O I
暂无
中图分类号
学科分类号
摘要
(Edited Abstract)
引用
收藏
页码:27 / 40
相关论文
共 50 条
  • [21] WEARABLE ARTIFICIAL ENDOCRINE PANCREAS WITH NEEDLE-TYPE GLUCOSE SENSOR
    SHICHIRI, M
    KAWAMORI, R
    YAMASAKI, Y
    HAKUI, N
    ABE, H
    LANCET, 1982, 2 (8308): : 1129 - 1131
  • [22] AN AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR TESTED IN RATS AND MAN
    MATTHEWS, DR
    BOWN, E
    BECK, TW
    PLOTKIN, E
    LOCK, L
    GOSDEN, E
    WICKHAM, M
    DIABETIC MEDICINE, 1988, 5 (03) : 248 - 252
  • [23] A BIOCOMPATIBLE NEEDLE-TYPE GLUCOSE SENSOR BASED ON PLATINUM-ELECTROPLATED CARBON ELECTRODE
    CHEN, CY
    TAMIYA, E
    ISHIHARA, K
    KOSUGI, Y
    SU, YC
    NAKABAYASHI, N
    KARUBE, I
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1992, 36 (03) : 211 - 226
  • [24] PROGRESS OF THE DEVELOPMENT AND CALIBRATION OF NEEDLE-TYPE ULTRASONIC HYDROPHONE
    Wu, Hong
    He, Long-biao
    Zhou, Jing-lin
    Yang, Ping
    2013 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2013, : 249 - 252
  • [25] DEVELOPMENT OF A NEEDLE-TYPE GLUCOSE SENSOR-BASED ON A TITANIUM-DIOXIDE OXYGEN-ELECTRODE FOR THE ARTIFICIAL PANCREAS
    IKEDA, S
    HARA, M
    HISHIDA, Y
    KIMURA, M
    ITO, K
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 315 - 318
  • [26] Development of scanning method for puncture needle-type ultrasonography
    Tokyo Metropolitan College of Industrial Technology, 8-17-1 Minamisenjyu, Arakawa, Tokyo 116-0003, Japan
    不详
    不详
    不详
    Jpn. J. Appl. Phys., 7 PART 2
  • [27] Development of Scanning Method for Puncture Needle-Type Ultrasonography
    Yoshizawa, Masasumi
    Emoto, Ryuuji
    Kawabata, Hirotaka
    Irie, Takasuke
    Itoh, Kouichi
    Moriya, Tadashi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2009, 48 (07)
  • [28] THE WEARABLE ARTIFICIAL ENDOCRINE PANCREAS - THE CHARACTERISTICS OF NEEDLE-TYPE GLUCOSE SENSOR
    SHICHIRI, M
    KAWAMORI, R
    GORIYA, Y
    YAMASAKI, Y
    NOMURA, M
    ABE, H
    DIABETOLOGIA, 1981, 21 (03) : 328 - 328
  • [29] DESIGN AND INVITRO STUDIES OF A NEEDLE-TYPE GLUCOSE SENSOR FOR SUBCUTANEOUS MONITORING
    BINDRA, DS
    ZHANG, YN
    WILSON, GS
    STERNBERG, R
    THEVENOT, DR
    MOATTI, D
    REACH, G
    ANALYTICAL CHEMISTRY, 1991, 63 (17) : 1692 - 1696
  • [30] BIOCOMPATIBLE NEEDLE-TYPE GLUCOSE SENSOR WITH POTENTIAL FOR USE IN-VIVO
    CHEN, CY
    SU, YC
    ISHIHARA, K
    NAKABAYASHI, N
    TAMIYA, E
    KARUBE, I
    ELECTROANALYSIS, 1993, 5 (04) : 269 - 276