Study and development of multilayer needle-type enzyme-based glucose microsensors

被引:0
|
作者
Sternberg, R. [1 ]
Barrau, M.-B. [1 ]
Gangiotti, L. [1 ]
Thevenot, D.R. [1 ]
Bindra, D.S. [1 ]
Wilson, G.S. [1 ]
Velho, G. [1 ]
Froguel, P. [1 ]
Reach, G. [1 ]
机构
[1] Laboratoire de Bioelectrochimie et Analyse du Milieu, U.F.R. de Sciences et de Technologie, Universite Paris-Val de Marne, 94010 Creteil Cedex, France
关键词
Covalent Coupling - Glucose Microsensors - Needle Sensor - Subcutaneous Implant;
D O I
暂无
中图分类号
学科分类号
摘要
(Edited Abstract)
引用
收藏
页码:27 / 40
相关论文
共 50 条
  • [41] Development of Robust Sensing System for Puncture Needle-Type Ultrasonography
    Yoshizawa, Masasumi
    Irie, Takasuke
    Itoh, Kouichi
    Moriya, Tadashi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (07)
  • [42] DEVELOPMENT OF AN ENZYME-BASED ASSAY FOR ACETAMINOPHEN
    HAMMOND, PM
    SCAWEN, MD
    ATKINSON, T
    CAMPBELL, RS
    PRICE, CP
    ANALYTICAL BIOCHEMISTRY, 1984, 143 (01) : 152 - 157
  • [43] Development of a PVDF needle-type hydrophone for measuring ultrasonic fields
    Boechat, Flavio M. B.
    Rodrigues, Estevao P.
    de Oliveira, Timoteo F.
    Buiochi, Flavio
    2018 13TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2018, : 1004 - 1007
  • [44] Fabrication of an Implantable Fine Needle-Type Glucose Sensor Using γ-Polyglutamic Acid
    Takaoka, Hiroki
    Yasuzawa, Mikito
    ANALYTICAL SCIENCES, 2010, 26 (05) : 551 - 555
  • [45] Needle-type environmental microsensors: design, construction and uses of microelectrodes and multi-analyte MEMS sensor arrays
    Lee, Woo Hyoung
    Lee, Jin-Hwan
    Choi, Woo-Hyuck
    Hosni, Ahmed A.
    Papautsky, Ian
    Bishop, Paul L.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (04)
  • [46] EVALUATING INVITRO AND INVIVO, THE INTERFERENCE OF ASCORBATE AND ACETAMINOPHEN ON GLUCOSE DETECTION BY A NEEDLE-TYPE GLUCOSE SENSOR
    MOATTISIRAT, D
    VELHO, G
    REACH, G
    BIOSENSORS & BIOELECTRONICS, 1992, 7 (05): : 345 - 352
  • [47] Fabrication of an Implantable Fine Needle-Type Glucose Sensor Using γ-Polyglutamic Acid
    Hiroki Takaoka
    Mikito Yasuzawa
    Analytical Sciences, 2010, 26 : 551 - 555
  • [48] INVIVO CALIBRATION OF A NEEDLE-TYPE GLUCOSE SENSOR TO DETERMINE THE KINETICS OF SUBCUTANEOUS GLUCOSE-CONCENTRATION
    VELHO, G
    FROGUEL, P
    REACH, G
    THEVENOT, D
    DIABETOLOGIA, 1987, 30 (07) : A592 - A592
  • [49] ENZYME-BASED FIBER OPTIC SENSOR FOR GLUCOSE DETERMINATION
    ABDELLATIF, MS
    SULEIMAN, AA
    GUILBAULT, GG
    ANALYTICAL LETTERS, 1988, 21 (06) : 943 - 951
  • [50] Development of Cu nanoflowers modified the flexible needle-type microelectrode and its application in continuous monitoring glucose in vivo
    Fang, Yuxin
    Wang, Shenjun
    Liu, Yangyang
    Xu, Zhifang
    Zhang, Kuo
    Guo, Yi
    BIOSENSORS & BIOELECTRONICS, 2018, 110 : 44 - 51