Study and development of multilayer needle-type enzyme-based glucose microsensors

被引:0
|
作者
Sternberg, R. [1 ]
Barrau, M.-B. [1 ]
Gangiotti, L. [1 ]
Thevenot, D.R. [1 ]
Bindra, D.S. [1 ]
Wilson, G.S. [1 ]
Velho, G. [1 ]
Froguel, P. [1 ]
Reach, G. [1 ]
机构
[1] Laboratoire de Bioelectrochimie et Analyse du Milieu, U.F.R. de Sciences et de Technologie, Universite Paris-Val de Marne, 94010 Creteil Cedex, France
关键词
Covalent Coupling - Glucose Microsensors - Needle Sensor - Subcutaneous Implant;
D O I
暂无
中图分类号
学科分类号
摘要
(Edited Abstract)
引用
收藏
页码:27 / 40
相关论文
共 50 条
  • [31] Label-free, needle-type biosensor for continuous glucose monitoring based on competitive binding
    Paek, Sung-Ho
    Cho, Il-Hoon
    Kim, Dong-Hyung
    Jeon, Jin-Woo
    Lim, Guei-Sam
    Paek, Se-Hwan
    BIOSENSORS & BIOELECTRONICS, 2013, 40 (01): : 38 - 44
  • [32] PLANAR AMPEROMETRIC ENZYME-BASED GLUCOSE MICROELECTRODE
    KOUDELKA, M
    GERNET, S
    DEROOIJ, NF
    SENSORS AND ACTUATORS, 1989, 18 (02): : 157 - 165
  • [33] DIRECT MEASUREMENT OF WHOLE-BLOOD GLUCOSE BY A NEEDLE-TYPE SENSOR
    YAMASAKI, Y
    UEDA, N
    NAO, K
    SEKIYA, M
    KAWAMORI, R
    SHICHIRI, M
    KAMADA, T
    CLINICA CHIMICA ACTA, 1989, 180 (01) : 93 - 98
  • [34] Development and Characterization of Needle-type Ion-selective Microsensors for insitu Determination of Foliar Uptake of Zn2+ in Citrus Plants
    Church, Jared
    Armas, Stephanie M.
    Patel, Parth K.
    Chumbimuni-Torres, Karin
    Lee, Woo Hyoung
    ELECTROANALYSIS, 2018, 30 (04) : 626 - 632
  • [35] Glucose Monitoring by Direct Electron Transfer Needle-Type Miniaturized Electrode
    Shimizu, Hitomi
    Tsugawa, Wakako
    ELECTROCHEMISTRY, 2012, 80 (05) : 375 - 378
  • [36] Needle-type glucose biosensors based on a pyrolyzed cobalt-tetramethoxy-phenylporphyrin catalytic electrode
    Atanasov, P
    Gamburzev, S
    Wilkins, E
    ELECTROANALYSIS, 1996, 8 (02) : 158 - 164
  • [37] Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas
    Ichimori S.
    Nishida K.
    Shimoda S.
    Sekigami T.
    Matsuo Y.
    Ichinose K.
    Shichiri M.
    Sakakida M.
    Araki E.
    Journal of Artificial Organs, 2006, 9 (2) : 105 - 113
  • [38] The development of an enzyme-based sensor for iodide
    Palmer, GJ
    Blair, TL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 42 - ANYL
  • [39] Comparison of a needle-type and a microdialysis continuous glucose monitor in type 1 diabetic patients
    Wentholt, IM
    Vollebregt, MA
    Hart, AA
    Hoekstra, JB
    DeVries, JH
    DIABETES CARE, 2005, 28 (12) : 2871 - 2876
  • [40] Unconventional Layer-by-Layer Assembly of Graphene Multilayer Films for Enzyme-Based Glucose and Maltose Biosensing
    Zeng, Guanghong
    Xing, Yibo
    Gao, Jian
    Wang, Zhiqiang
    Zhang, Xi
    LANGMUIR, 2010, 26 (18) : 15022 - 15026