A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T1 estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T1 measurements was examined. Experiments were performed on different Gd-doped water phantoms and on humans. T1 values derived from inversion recovery TrueFISP were in excellent agreement with the single-point method even for flip angles up to 50. In terms of T1 accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. © 2001 Wiley-Liss, Inc.
引用
收藏
相关论文
共 50 条
  • [11] Simultaneous T1 and T2 measurements using inversion recovery TrueFISP with principle component-based reconstruction, off-resonance correction, and multicomponent analysis
    Pfister, Julian
    Blaimer, Martin
    Kullmann, Walter H.
    Bartsch, Andreas J.
    Jakob, Peter M.
    Breuer, Felix A.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3488 - 3502
  • [12] NMR - A COMPARISON OF INVERSION RECOVERY, SATURATION RECOVERY, AND T1 MEASUREMENTS IN THE BRAIN AND SPINE
    WEINSTEIN, MA
    MODIC, MT
    DUCHESNEAU, PM
    STARNES, D
    RADIOLOGY, 1982, 144 (04) : 945 - 945
  • [13] MEASUREMENT OF T1 USING THE MULTIPLE INVERSION-RECOVERY SEQUENCE
    YOUNG, IR
    BYDDER, GM
    COLLINS, AG
    HALL, AS
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 788 - 788
  • [14] T1 mapping of myocardium using inversion recovery cine at 3.0T
    Yanjie Zhu
    Yinzhu Gao
    Yiu-Cho Chung
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [15] IR TrueFISP with a golden-ratio-based radial readout: Fast quantification of T1, T2, and proton density
    Ehses, Philipp
    Seiberlich, Nicole
    Ma, Dan
    Breuer, Felix A.
    Jakob, Peter M.
    Griswold, Mark A.
    Gulani, Vikas
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (01) : 71 - 81
  • [16] Myocardial iron quantification using modified Look-Locker inversion recovery (MOLLI) T1 mapping at 3 Tesla
    GC Camargo
    T Rothstein
    FP Junqueira
    E Fernandes
    RL Lima
    A Greiser
    R Strecker
    JA Lima
    SS Xavier
    I Gottlieb
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [17] MULTISLICE INVERSION-RECOVERY T1 DETERMINATION USING OPTIMIZED PULSES
    ROBERTS, TPL
    CARPENTER, TA
    HALL, LD
    JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (01): : 160 - 164
  • [18] A PULSE SEQUENCE FOR T1 MEASUREMENT BY INVERSION RECOVERY IN THE PRESENCE OF ACOUSTIC RINGING
    BAGNO, A
    MAGNETIC RESONANCE IN CHEMISTRY, 1992, 30 (12) : 1164 - 1168
  • [19] 2-STAGE INVERSION-RECOVERY EXPERIMENTS FOR MEASUREMENTS OF T1
    TAITELBAUM, H
    FERRETTI, JA
    SPENCER, RGS
    WEISS, GH
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 105 (01) : 59 - 64
  • [20] Optimized Inversion Recovery Sequences for Quantitative T1 and Magnetization Transfer Imaging
    Li, Ke
    Zu, Zhongliang
    Xu, Junzhong
    Janve, Vaibhav A.
    Gore, John C.
    Does, Mark D.
    Gochberg, Daniel F.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 491 - 500