T1 quantification with inversion recovery TrueFISP

被引:0
|
作者
机构
[1] Scheffler, Klaus
[2] Hennig, Jrgen
来源
Scheffler, K. (ksch@ukl.uni-freiburg.de) | 1600年 / John Wiley and Sons Inc.卷 / 45期
关键词
Systematic errors - Magnetization;
D O I
暂无
中图分类号
O441.2 [磁学]; TM12 [];
学科分类号
摘要
A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T1 estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T1 measurements was examined. Experiments were performed on different Gd-doped water phantoms and on humans. T1 values derived from inversion recovery TrueFISP were in excellent agreement with the single-point method even for flip angles up to 50. In terms of T1 accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. © 2001 Wiley-Liss, Inc.
引用
收藏
相关论文
共 50 条
  • [31] EVALUATION OF THE INVERSION-RECOVERY AND DESPOT METHODS FOR MEASUREMENT OF T1 OF THE POLYSACCHARIDE PULLULAN
    HOFFMAN, RE
    DAVIES, DB
    JOURNAL OF MAGNETIC RESONANCE, 1988, 80 (02): : 318 - 323
  • [32] Fast myocardial T1 mapping using shortened inversion recovery based schemes
    Huang, Li
    Neji, Radhouene
    Nazir, Muhummad Sohaib
    Whitaker, John
    Reid, Fiona
    Bosio, Filippo
    Chiribiri, Amedeo
    Razavi, Reza
    Roujol, Sebastien
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (02) : 641 - 654
  • [33] The measurement of myocardial T1 relaxation times in humans with inversion recovery EPI.
    Pongnapang, N
    Clarke, GD
    Ozus, B
    Amurao, M
    Lane, M
    Belden, C
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 898 - 904
  • [34] IMAGING SPINAL OSTEOMYELITIS AND EPIDURAL ABSCESS WITH SHORT T1 INVERSION RECOVERY (STIR)
    BERTINO, RE
    PORTER, BA
    STIMAC, GK
    TEPPER, SJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (03) : 563 - 564
  • [35] THE CHOICE OF PARAMETERS IN AN NMR EXPERIMENT - APPLICATION TO THE INVERSION-RECOVERY T1 METHOD
    BAIN, AD
    JOURNAL OF MAGNETIC RESONANCE, 1990, 89 (01): : 153 - 160
  • [36] Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values
    Saunders, Adam M.
    Kim, Michael E.
    Gao, Chenyu
    Remedios, Lucas W.
    Krishnan, Aravind R.
    Schilling, Kurt G.
    O'Grady, Kristin P.
    Smith, Seth A.
    Landman, Bennett A.
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [37] 23Na-T1quantification with saturation recovery TrueFISP and variable flip angle GRE at 3T: A phantom study
    Gomolka, Ryszard S.
    Ciritsis, Alexander
    Rossi, Cristina
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (06) : 3300 - 3307
  • [38] Myocardial T1: Quantification by Using an ECG-triggered Radial Single-Shot Inversion-Recovery MR Imaging Sequence
    Gensler, Daniel
    Moerchel, Philipp
    Fidler, Florian
    Ritter, Oliver
    Quick, Harald H.
    Ladd, Mark E.
    Bauer, Wolfgang R.
    Ertl, Georg
    Jakob, Peter M.
    Nordbeck, Peter
    RADIOLOGY, 2015, 274 (03) : 879 - 887
  • [39] T1 mapping from routine 3D T1-weighted inversion recovery sequences in clinical practice: comparison against reference inversion recovery fast field echo T1 scans and feasibility in multiple sclerosis
    Young, Griffin
    Nguyen, Vivian S.
    Howlett-Prieto, Quentin
    Abuaf, Amanda Frisosky
    Carroll, Timothy J.
    Kawaji, Keigo
    Javed, Adil
    NEURORADIOLOGY, 2024, 66 (10) : 1709 - 1719
  • [40] Single-shot inversion recovery trueFISP for assessment of myocardial infarction
    Huber, A
    Schoenberg, SO
    Spannag, B
    Rieber, J
    Erhard, I
    Klauss, V
    Reiser, MF
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 627 - 633