T1 quantification with inversion recovery TrueFISP

被引:0
|
作者
机构
[1] Scheffler, Klaus
[2] Hennig, Jrgen
来源
Scheffler, K. (ksch@ukl.uni-freiburg.de) | 1600年 / John Wiley and Sons Inc.卷 / 45期
关键词
Systematic errors - Magnetization;
D O I
暂无
中图分类号
O441.2 [磁学]; TM12 [];
学科分类号
摘要
A snapshot FLASH sequence can be used to acquire the time course of longitudinal magnetization during its recovery after a single inversion pulse. However, excitation pulses disturb the exponential recovery of longitudinal magnetization and may produce systematic errors in T1 estimations. In this context the possibility of using the TrueFISP sequence to detect the recovery of longitudinal magnetization for quantitative T1 measurements was examined. Experiments were performed on different Gd-doped water phantoms and on humans. T1 values derived from inversion recovery TrueFISP were in excellent agreement with the single-point method even for flip angles up to 50. In terms of T1 accuracy and SNR, the proposed method seems to be superior to the conventional inversion recovery snapshot FLASH technique. © 2001 Wiley-Liss, Inc.
引用
收藏
相关论文
共 50 条
  • [21] Myocardial T1 mapping at 3.0T using inversion recovery FLASH readout
    Jiaxin Shao
    Kim-Lien Nguyen
    Peng Hu
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [22] T1 inversion recovery pulse sequence: could it replace T1 spin echo sequence in neuroimaging by improving tissue contrast?
    Shawky, Mohamed
    Habib, Rehab
    Elsawaf, Ahmed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2019, 50 (01):
  • [23] T1 inversion recovery pulse sequence: could it replace T1 spin echo sequence in neuroimaging by improving tissue contrast?
    Mohamed Shawky
    Rehab Habib
    Ahmed Elsawaf
    Egyptian Journal of Radiology and Nuclear Medicine, 50
  • [24] Simultaneous T1 and T2 quantification of the myocardium using cardiac balanced-SSFP inversion recovery with interleaved sampling acquisition (CABIRIA)
    Santini, Francesco
    Kawel-Boehm, N.
    Greiser, A.
    Bremerich, J.
    Bieri, O.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (02) : 365 - 371
  • [25] Quantification of cerebral blood flow by flow-sensitive alternating inversion recovery exempting separate T1 measurement in healthy volunteers
    Xiao Jiang-xi
    Zhang Xue-hui
    Xie Sheng
    Zou Run-lei
    CHINESE MEDICAL JOURNAL, 2006, 119 (24) : 2096 - 2100
  • [27] Quantification of cerebral blood flow by flow-sensitive alternating inversion recovery exempting separate T1 measurement in healthy volunteers
    XIAO JiangxiZHANG XuehuiXIE Sheng and ZOU Runlei Department of RadiologyPeking University First HospitalBeijing China Institute of PhysicsPeking UniversityBeijing China
    ChineseMedicalJournal, 2006, (24) : 2096 - 2100
  • [28] Visualisation of fluid accumulation in T1 black holes using double inversion recovery
    Ikonomidou, V
    van Gelderen, R
    Tovar-Moll, E
    de Zwart, J
    Horovitz, S
    Calabrese, M
    Ohayon, J
    Tasciyan, T
    McFarland, HE
    Duyn, J
    Bagnato, F
    MULTIPLE SCLEROSIS, 2005, 11 : S57 - S57
  • [29] QUANTIFICATION OF MYOCARDIAL T1 UPTAKE
    CAVAILLOLES, F
    TODDPOKROPEK, AE
    PEYCELON, P
    BOK, B
    JOURNAL DE BIOPHYSIQUE & MEDECINE NUCLEAIRE, 1982, 6 (02): : 71 - 76
  • [30] Optimized precision of inversion-recovery T1 measurements for constrained scan time
    Ogg, RJ
    Kingsley, PB
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) : 625 - 630