Quantitative and qualitative performance evaluation of commercial metal artifact reduction methods: Dosimetric effects on the treatment planning

被引:0
|
作者
Ghorbanzadeh, Mohammad [1 ]
Hosseini, Seyed Abolfazl [1 ]
Vahdat, Bijan Vosoughi [2 ]
Mirzaiy, Hamed [3 ]
Akhavanallaf, Azadeh [4 ]
Arabi, Hossein [4 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran 863911365, Iran
[2] Sharif Univ Technol, Dept Elect Engn, Tehran 863911365, Iran
[3] Erfan Radiat Oncol Ctr EROC, Tehran 57176, Iran
[4] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
关键词
Computerized tomography; Metal artifact reduction; Radiation therapy; CLINICAL-EVALUATION; CT; RESOLUTION; RADIATION; IMPLANTS; DESIGN;
D O I
10.1016/j.radphyschem.2024.112140
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The presence of metal implants within CT imaging causes severe attenuation of the X-ray beam. Due to the incomplete information recorded by CT detectors, artifacts in the form of streaks and dark bands would appear in the resulting CT images. The metal-induced artifacts would firstly affect the quantitative accuracy of CT imaging, and consequently, the radiation treatment planning and dose estimation in radiation therapy. To address this issue, CT scanner vendors have implemented metal artifact reduction (MAR) algorithms to avoid such artifacts and enhance the overall quality of CT images. The orthopedic-MAR (OMAR) and normalized MAR (NMAR) algorithms are the most well-known metal artifact reduction (MAR) algorithms, used worldwide. These algorithms have been implemented on Philips and Siemens scanners, respectively. In this study, we set out to quantitatively and qualitatively evaluate the effectiveness of these two MAR algorithms and their impact on accurate radiation treatment planning and CT-based dosimetry. The quantitative metrics measured on the simulated metal artifact dataset demonstrated superior performance of the OMAR technique over the NMAR one in metal artifact reduction. The analysis of radiation treatment planning using the OMAR and NMAR techniques in the corrected CT images showed that the OMAR technique reduced the toxicity of healthy tissues by 10% compared to the uncorrected CT images.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [31] Comprehensive evaluation of artifact reduction and tissue recovery effects of metal artifact reduction technique based on full-reference metric
    Jung, Yunsub
    Song, You Seon
    Lee, In Sook
    Rhee, Seung Joon
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [32] Comprehensive evaluation of artifact reduction and tissue recovery effects of metal artifact reduction technique based on full-reference metric
    Yunsub Jung
    You Seon Song
    In Sook Lee
    Seung Joon Rhee
    Scientific Reports, 13
  • [33] A Novel Method for Segmentation-Based Semiautomatic Quantitative Evaluation of Metal Artifact Reduction Algorithms
    Do, Thur D.
    Sommer, Christof M.
    Melzig, Claudius
    Nattenmueller, Johanna
    Vollherbst, Dominik
    Kauczor, Hans-Ulrich
    Stiller, Wolfram
    Skornitzke, Stephan
    INVESTIGATIVE RADIOLOGY, 2019, 54 (06) : 365 - 373
  • [34] On Clinical Utility of Orthopedic Metal Artifact Reduction (OMAR) Software in CT Simulation and Treatment Planning
    Jani, S. K.
    Pothilat, J.
    Santos, A.
    Glazebrook, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S872 - S872
  • [35] Dosimetric impact of commercial CT metal artifact reduction algorithms and a novel in-house algorithm for proton therapy of head and neck cancer
    Branco, Daniela
    Kry, Stephen
    Taylor, Paige
    Zhang, Xiaodong
    Rong, John
    Frank, Steven
    Followill, David
    MEDICAL PHYSICS, 2021, 48 (01) : 445 - 455
  • [36] Quantitative radioimmunoimaging (RAII) for radioimmunotherapy (RAIT) treatment planning: Effect of reduction in data sampling on dosimetric estimates.
    Erwin, WD
    Groch, MW
    Lands, BJ
    Spies, SM
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 269P - 269P
  • [37] Dosimetric evaluation of the clinical implementation of the first commercial IMRT Monte Carlo treatment planning system at 6 MV
    Heath, E
    Seuntjens, J
    Sheikh-Bagheri, D
    MEDICAL PHYSICS, 2004, 31 (10) : 2771 - 2779
  • [38] Clinical Evaluation of Normalized Metal Artifact Reduction in kVCT Using MVCT Prior Images (MVCT-NMAR) for Radiation Therapy Treatment Planning
    Paudel, Moti Raj
    Mackenzie, Marc
    Fallone, B. Gino
    Rathee, Satyapal
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 89 (03): : 682 - 689
  • [39] Performance analysis of a film dosimetric quality assurance procedure for IMRT with regard to the employment of quantitative evaluation methods
    Winkler, P
    Zurl, B
    Guss, H
    Kindl, P
    Stuecklschweiger, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (04): : 643 - 654
  • [40] Evaluation of Dosimetric Effects of Use of Deformably-Mapped Contours for Lung IMRT Treatment Planning
    Dogan, N.
    Sleeman, W.
    Fatyga, M.
    Lehman, W.
    Weiss, E.
    Christensen, G.
    Williamson, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S727 - S728