Quantitative and qualitative performance evaluation of commercial metal artifact reduction methods: Dosimetric effects on the treatment planning

被引:0
|
作者
Ghorbanzadeh, Mohammad [1 ]
Hosseini, Seyed Abolfazl [1 ]
Vahdat, Bijan Vosoughi [2 ]
Mirzaiy, Hamed [3 ]
Akhavanallaf, Azadeh [4 ]
Arabi, Hossein [4 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, Tehran 863911365, Iran
[2] Sharif Univ Technol, Dept Elect Engn, Tehran 863911365, Iran
[3] Erfan Radiat Oncol Ctr EROC, Tehran 57176, Iran
[4] Geneva Univ Hosp, Div Nucl Med & Mol Imaging, CH-1211 Geneva, Switzerland
关键词
Computerized tomography; Metal artifact reduction; Radiation therapy; CLINICAL-EVALUATION; CT; RESOLUTION; RADIATION; IMPLANTS; DESIGN;
D O I
10.1016/j.radphyschem.2024.112140
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The presence of metal implants within CT imaging causes severe attenuation of the X-ray beam. Due to the incomplete information recorded by CT detectors, artifacts in the form of streaks and dark bands would appear in the resulting CT images. The metal-induced artifacts would firstly affect the quantitative accuracy of CT imaging, and consequently, the radiation treatment planning and dose estimation in radiation therapy. To address this issue, CT scanner vendors have implemented metal artifact reduction (MAR) algorithms to avoid such artifacts and enhance the overall quality of CT images. The orthopedic-MAR (OMAR) and normalized MAR (NMAR) algorithms are the most well-known metal artifact reduction (MAR) algorithms, used worldwide. These algorithms have been implemented on Philips and Siemens scanners, respectively. In this study, we set out to quantitatively and qualitatively evaluate the effectiveness of these two MAR algorithms and their impact on accurate radiation treatment planning and CT-based dosimetry. The quantitative metrics measured on the simulated metal artifact dataset demonstrated superior performance of the OMAR technique over the NMAR one in metal artifact reduction. The analysis of radiation treatment planning using the OMAR and NMAR techniques in the corrected CT images showed that the OMAR technique reduced the toxicity of healthy tissues by 10% compared to the uncorrected CT images.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [41] Reduction of Metallic Artifacts of the Post-treatment Intracranial Aneurysms: Effects of Single Energy Metal Artifact Reduction Algorithm
    Pan, Yu-Ning
    Chen, Ge
    Li, Ai-Jing
    Chen, Zhao-Qian
    Gao, Xiang
    Huang, Yi
    Mattson, Bradley
    Li, Shan
    CLINICAL NEURORADIOLOGY, 2019, 29 (02) : 277 - 284
  • [42] Reduction of Metallic Artifacts of the Post-treatment Intracranial Aneurysms: Effects of Single Energy Metal Artifact Reduction Algorithm
    Yu-Ning Pan
    Ge Chen
    Ai-Jing Li
    Zhao-Qian Chen
    Xiang Gao
    Yi Huang
    Bradley Mattson
    Shan Li
    Clinical Neuroradiology, 2019, 29 : 277 - 284
  • [43] The Use of Dual-Energy CT Images for Monte Carlo Treatment Planning: Material Extraction and Metal Artifact Reduction
    Bazalova, M.
    Beaulieu, L.
    Carrier, J.
    Vigneault, E.
    Verhaegen, F.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [44] An adaptive approach to metal artifact reduction in helical computed tomography for radiation therapy treatment planning: Experimental and clinical studies
    Yazdia, M
    Gingras, L
    Beaulieu, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04): : 1224 - 1231
  • [45] Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for 125I prostate implants
    Assam, Isong
    Vijande, Javier
    Ballester, Facundo
    Perez-Calatayud, Jose
    Poppe, Bjorn
    Siebert, Frank-Andre
    MEDICAL PHYSICS, 2022, 49 (09) : 6195 - 6208
  • [46] Dosimetric evaluation of a commercial 3-D treatment planning system using Report 55 by AAPM Task Group 23
    Declich, F
    Fumasoni, K
    Mangili, P
    Cattaneo, GM
    Iori, M
    RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) : 69 - 77
  • [47] Dosimetric evaluation of a commercial 3D treatment planning system using the AAPM Task Group 23 test package
    Borca, VC
    Pasquino, M
    Bresciani, S
    Catuzzo, P
    Ozzello, F
    Tofani, S
    MEDICAL PHYSICS, 2005, 32 (03) : 744 - 751
  • [48] Evaluation of projection- and dual-energy-based methods for metal artifact reduction in CT using a phantom study
    Long, Zaiyang
    Bruesewitz, Michael R.
    DeLone, David R.
    Morris, Jonathan M.
    Amrami, Kimberly K.
    Adkins, Mark C.
    Glazebrook, Katrina N.
    Kofler, James M.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    Halaweish, Ahmed F.
    Yu, Lifeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 252 - 260
  • [49] Image Quality of Commercial CT Metal Artifact Reduction Algorithms and a Novel In-House Algorithm for Head and Neck (H&N) Cancer and the Dosimetric Implications On Proton Therapy
    Branco, D.
    Kry, S.
    Taylor, P.
    Zhang, X.
    Rong, J.
    Frank, S.
    Followill, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E790 - E790
  • [50] The performance of metal artifact reduction algorithms in cone beam computed tomography images considering the effects of materials, metal positions, and fields of view
    Vasconcelos, Karla de Faria
    Codari, Marina
    Queiroz, Polyane Mazucatto
    Pinheiro Nicolielo, Laura Ferreira
    Freitas, Deborah Queiroz
    Sforza, Chiarella
    Jacobs, Reinhilde
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 127 (01): : 71 - 76