Dosimetric response of radiophotoluminescent glass detectors in a scanning pencil proton beam

被引:0
|
作者
Pasaricek, Luka [1 ]
Knezevic, Zeljka [1 ]
Brkic, Hrvoje [2 ,3 ]
Davidkova, Marie [4 ]
Navratil, Matej [5 ]
Vondracek, Vladimir [5 ]
Majer, Marija [1 ]
机构
[1] Rudjer Boskovic Inst, Zagreb, Croatia
[2] Fac Med Osijek, Osijek, Croatia
[3] Fac Dent Med & Hlth Osijek, Osijek, Croatia
[4] CAS, Radiat Dosimetry Dept, Nucl Phys Inst, Prague, Czech Republic
[5] Proton Therapy Ctr Czech Sro, Prague, Czech Republic
关键词
Dose response; Relative efficiency; RPL glass detector; Scanning pencil proton beam; OPTICALLY STIMULATED LUMINESCENCE; THERMOLUMINESCENCE EFFICIENCY; RELATIVE EFFICIENCY; ENERGY PHOTON; TL DETECTORS; PHOTOLUMINESCENCE; DEPENDENCE; AL2O3C; FIELD;
D O I
10.1016/j.radmeas.2024.107195
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The dose and linear energy transfer (LET) dependence of the radiophotoluminescence (RPL) response was evaluated for RPL glass detectors, taken from the environmental dosimeter type SC-1, using a clinical 100 MeV and 200 MeV scanning pencil proton beam. The measurements were performed at different positions along the Bragg curves. The fluence-averaged (LETf) and dose-averaged (LETd) LET at the positions of the detectors were calculated using two Monte Carlo codes (MCNP and PHITS). Before measurements in proton beams, the linearity of the dose response for the dose range of interest (up to 10 Gy) was checked and confirmed in a Co-60 gamma ray field, since the FGD-202 reader for SC-1 dosimeters is usually used for doses up to 1 Gy and we found no data for higher doses in the literature. For proton beams, the linear dose response was determined for the doses investigated from 0.5 Gy to 8.8 Gy. For the LET range, which corresponds to the LETd from 0.47 keV/mu m to 4.70 keV/mu m, a decrease in response with an increase in LET was observed.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] An approach for estimating dosimetric uncertainties in deformable dose accumulation in pencil beam scanning proton therapy for lung cancer
    Amstutz, Florian
    Nenoff, Lena
    Albertini, Francesca
    Ribeiro, Cassia O.
    Knopf, Antje C.
    Unkelbach, Jan
    Weber, Damien C.
    Lomax, Antony J.
    Zhang, Ye
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (10):
  • [42] Investigation of linear energy transfer (LET)-dependence behavior and dosimetric response of a flat-panel detector in pencil beam scanning proton therapy
    Park, Jiyeon
    Reiners, Keaton
    Ho, Meng Wei
    Huh, Soon
    Liu, Chunbo
    Johnson, Perry
    Zhang, Yawei
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 125
  • [43] Absorbed Dose Measurement Using Radiophotoluminescent Glass Dosimeter in Therapeutic Proton Beam
    Chang, W.
    Koba, Y.
    Katayose, T.
    Hariu, M.
    Yasui, K.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3502 - 3502
  • [44] Technical note: Delivery benefit and dosimetric implication of synchrotron-based proton pencil beam scanning using continuous scanning mode
    Liang, Xiaoying
    Beltran, Chris J.
    Liu, Chunbo
    Shen, Jiajian
    Li, Heng
    Furutani, Keith M.
    [J]. MEDICAL PHYSICS, 2023, 50 (08) : 5252 - 5261
  • [45] Dosimetric Correlation of Acute Radiation Dermatitis in Patients With Breast Cancer Undergoing Hypofractionated Proton Beam Therapy Using Pencil Beam Scanning
    Huang, Eng-Yen
    Ho, Meng Wei
    Wang, Yu-Ming
    [J]. JOURNAL OF BREAST CANCER, 2024, 27 (03) : 187 - 200
  • [46] Impact of Dosimetric Compromises on Early Outcomes of Chordomas and Chondrosarcomas Treated With Image-guided Pencil Beam Scanning Proton Beam Therapy
    Chilukuri, Srinivas
    Burela, Nagarjuna
    Sundar, Sham
    Kamath, Ramakrishna
    Nangia, Sapna
    Arjunan, Manikandan
    Kumar, Roopesh
    Ramanujam, Vishnu
    Chacko, Ari
    Sharma, Dayananda Shamurailatpam
    Jalali, Rakesh
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (10)
  • [47] Proton pencil-beam scanning radiotherapy in the treatment of nasopharyngeal cancer: dosimetric parameters and 2-year results
    Kubes, Jiri
    Vondracek, Vladimir
    Andrlik, Michal
    Navratil, Matej
    Slavikova, Silvia
    Vitek, Pavel
    Dedeckova, Katerina
    Prausova, Jana
    Ondrova, Barbora
    Rotnaglova, Eliska
    Lukes, Petr
    Patzelt, Matej
    Grebenyuk, Alexander
    Rosina, Jozef
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (03) : 763 - 769
  • [48] Time structure of pencil beam scanning proton FLASH beams measured with scintillator detectors and compared with log files
    Kanouta, Eleni
    Johansen, Jacob Graversen
    Kertzscher, Gustavo
    Sitarz, Mateusz Krzysztof
    Sorensen, Brita Singers
    Poulsen, Per Rugaard
    [J]. MEDICAL PHYSICS, 2022, 49 (03) : 1932 - 1943
  • [49] Dosimetric analysis of local failures in skull-base chordoma and chondrosarcoma following pencil beam scanning proton therapy
    Basler, Lucas
    Poel, Robert
    Schroeder, Christina
    Bolsi, Alessandra
    Lomax, Antony
    Tanadini-Lang, Stephanie
    Guckenberger, Matthias
    Weber, Damien C.
    [J]. RADIATION ONCOLOGY, 2020, 15 (01)
  • [50] Proton pencil-beam scanning radiotherapy in the treatment of nasopharyngeal cancer: dosimetric parameters and 2-year results
    Kubeš Jiří
    Vondráček Vladimír
    Andrlik Michal
    Navrátil Matěj
    Sláviková Silvia
    Vítek Pavel
    Dědečková Kateřina
    Prausová Jana
    Ondrová Barbora
    Rotnáglová Eliška
    Lukeš Petr
    Patzelt Matěj
    Grebenyuk Alexander
    Rosina Jozef
    [J]. European Archives of Oto-Rhino-Laryngology, 2021, 278 : 763 - 769