Absorbed Dose Measurement Using Radiophotoluminescent Glass Dosimeter in Therapeutic Proton Beam

被引:0
|
作者
Chang, W.
Koba, Y.
Katayose, T.
Hariu, M.
Yasui, K.
Saitoh, H.
机构
关键词
D O I
10.1118/1.4956312
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-T-175
引用
收藏
页码:3502 / 3502
页数:1
相关论文
共 50 条
  • [1] Feasubility Study of Absorbed Dose Estimation Using Radiophotoluminescence Glass Dosimeter for Proton Therapeutic Beam
    Chang, W.
    Kadoya, N.
    Hashimoto, S.
    Fujita, Y.
    Kato, T.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3514 - U48
  • [2] Investigation of Radiophotoluminescent Glass Dosimeter Response for a Spot Scanning Proton Beam Dosimetry
    Nagata, J.
    Yasui, K.
    Hayashi, N.
    Ogawa, S.
    Ouchi, K.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E804 - E804
  • [3] Evaluation of radiophotoluminescent glass dosimeter response for therapeutic spot scanning proton beam: suggestion of linear energy transfer-based correction
    Nagata, Junya
    Yasui, Keisuke
    Omachi, Chihiro
    Toshiyuki, Toshito
    Shimizu, Hidetoshi
    Aoyama, Takahiro
    Hayashi, Naoki
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 265 - 272
  • [4] A formalism for the absorbed dose evaluation of the glass dosimeter
    Park, Ka -Young
    Kim, Hyun-Chul
    Kim, Byoung-Chul
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (06) : 2283 - 2287
  • [5] EFFECTIVE DOSE MEASUREMENT FOR CONE BEAM COMPUTED TOMOGRAPHY USING GLASS DOSIMETER
    Moon, Young Min
    Kim, Hyo-Jin
    Kwak, Dong Won
    Kang, Yeong-Rok
    Lee, Man Woo
    Ro, Tae-Ik
    Kim, Jeung Kee
    Jeong, Dong Hyeok
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2014, 46 (02) : 255 - 262
  • [6] Feasibility study of radiophotoluminescent glass rod dosimeter postal dose intercomparison for high energy photon beam
    Rah, Jeong-Eun
    Kim, Siyong
    Cheong, Kwang-Ho
    Lee, Jeong-Woo
    Chung, Jin-Beom
    Shin, Dong-Oh
    Suh, Tae-Suk
    [J]. APPLIED RADIATION AND ISOTOPES, 2009, 67 (02) : 324 - 328
  • [7] Correction of stopping power and LET quenching for radiophotoluminescent glass dosimetry in a therapeutic proton beam
    Chang, Weishan
    Koba, Yusuke
    Katayose, Tetsurou
    Yasui, Keisuke
    Omachi, Chihiro
    Hariu, Masatsugu
    Saitoh, Hidetoshi
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (23): : 8869 - 8881
  • [8] Accuracy of radiophotoluminescence glass dosimeter for dose measurement of IMRT beam
    Hashimoto, S.
    Tohyama, N.
    Ishikura, S.
    Fujita, Y.
    Saitoh, H.
    Karasawa, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S144 - S145
  • [9] MEASUREMENT OF BETA-ABSORBED DOSE USING TLD PERSONAL DOSIMETER
    MIYABE, K
    NOMURA, Y
    ISHIGURO, H
    [J]. HEALTH PHYSICS, 1984, 46 (06): : 1327 - 1327
  • [10] The Beam Quality Dependence of a Radiophotoluminescent Glass Dosimeter in Megavoltage Photon and Electron Beams
    Araki, F.
    Ohno, T.
    Yoshiyama, F.
    Kohno, T.
    Wulff, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)