Feasubility Study of Absorbed Dose Estimation Using Radiophotoluminescence Glass Dosimeter for Proton Therapeutic Beam

被引:0
|
作者
Chang, W.
Kadoya, N.
Hashimoto, S.
Fujita, Y.
Kato, T.
Saitoh, H.
机构
关键词
D O I
10.1118/1.3612075
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-124
引用
收藏
页码:3514 / U48
页数:2
相关论文
共 50 条
  • [1] Absorbed Dose Measurement Using Radiophotoluminescent Glass Dosimeter in Therapeutic Proton Beam
    Chang, W.
    Koba, Y.
    Katayose, T.
    Hariu, M.
    Yasui, K.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3502 - 3502
  • [2] Accuracy of radiophotoluminescence glass dosimeter for dose measurement of IMRT beam
    Hashimoto, S.
    Tohyama, N.
    Ishikura, S.
    Fujita, Y.
    Saitoh, H.
    Karasawa, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S144 - S145
  • [3] Cumulative dose measurements using radiophotoluminescence glass dosimeter in cold area
    K. Yamazaki
    S. Tonouchi
    T. Hashimoto
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2003, 255 : 565 - 569
  • [4] Cumulative dose measurements using radiophotoluminescence glass dosimeter in cold areas
    Yamazaki, K
    Tonouchi, S
    Hashimoto, T
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2003, 255 (03) : 565 - 569
  • [5] FEASIBILITY STUDY OF RADIOPHOTOLUMINESCENCE GLASS DOSIMETER FOR POSTAL IMRT DOSE AUDIT
    Hashimoto, S.
    Kawachi, T.
    Kojima, T.
    Tohyama, N.
    Kurooka, M.
    Okamoto, H.
    Hayashi, N.
    Kumazaki, Y.
    Fujita, Y.
    Kitou, S.
    Hatano, K.
    Saitoh, H.
    Karasawa, K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S458 - S458
  • [6] Visualization of Radiation Dose Distribution Utilizing Radiophotoluminescence in Glass Dosimeter
    Nanto, Hidehito
    Yanagida, Yuka
    Sugiyama, Makoto
    Koguchi, Yasuhiro
    Ihara, Yohei
    Iida, Toshiyuki
    Shimizu, Kikuo
    Ikeguchi, Takuma
    Hirasawa, Kazuki
    Takei, Yoshinori
    Yamamotol, Takayoshi
    [J]. SENSORS AND MATERIALS, 2017, 29 (10) : 1439 - 1445
  • [7] A formalism for the absorbed dose evaluation of the glass dosimeter
    Park, Ka -Young
    Kim, Hyun-Chul
    Kim, Byoung-Chul
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (06) : 2283 - 2287
  • [8] A Method for Using a Radiophotoluminescence Glass Dosimeter in Accurate Tissue Dosimetry
    Pilsoo Lee
    Jae Seok Kim
    Wi-Ho Ha
    Byeong Ryong Park
    Han Sung Kim
    Gyu Seok Cho
    Kum Bae Kim
    Sunhoo Park
    Young-Woo Jin
    [J]. Journal of the Korean Physical Society, 2018, 72 : 444 - 448
  • [9] A Method for Using a Radiophotoluminescence Glass Dosimeter in Accurate Tissue Dosimetry
    Lee, Pilsoo
    Kim, Jae Seok
    Ha, Wi-Ho
    Park, Byeong Ryong
    Kim, Han Sung
    Cho, Gyu Seok
    Kim, Kum Bae
    Park, Sunhoo
    Jin, Young-Woo
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (03) : 444 - 448
  • [10] Beam Quality Correction of Radiophotoluminescence Glass Dosimeter in Accordance with Burlin Cavity Theory
    Hashimoto, S.
    Fujita, Y.
    Kawachi, T.
    Tohyama, N.
    Kojima, T.
    Hayashi, N.
    Kitou, S.
    Kurooka, M.
    Okamoto, H.
    Kumazaki, Y.
    Suzuki, Y.
    Hatano, K.
    Saitoh, H.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)