Efficiency Application of Monte Carlo Simulation and HPGe Detector Using Mapping Method

被引:0
|
作者
Jang, Eun-Sung [1 ]
Chang, Bo-Seok [2 ]
机构
[1] Kosin Univ, Gospel Hosp, Dept Radiat Oncol, Busan 49267, South Korea
[2] Kaya Univ, Depart Radiol Sci, Gimhae 50830, South Korea
关键词
mapping; monte carlo simulation; Computed Tomography (CT); HPGe detector; electromagnetic X-ray image; CALIBRATION;
D O I
10.4283/JMAG.2024.29.2.172
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to obtain the detection efficiency according to the distance around the detector, the total energy peak efficiency was used, and the grid mapping method was used to investigate axis-symmetry. The detector was measured at 0.5 cm intervals up to 5 cm in the x, z, direction, and 5.5 cm in the y direction. The efficiency of the cylinder beaker and marinelli beakers at the center of the 134Cs 604 keV detector was compared with the efficiency of the mapping method. For cylinder beakers, the efficiency was 0.0412 +/- 0.002, and the efficiency by mapping was 0.040 +/- 0.001, which was consistent within 3 % of the uncertainty range. For Marinelli beakers, the efficiency was 0.0242 +/- 0.002 mapping efficiency was 0.0248 +/- 0.0013. It was confirmed that precise measurement of radioactive sources with volume was possible when measured at each point around the detector.
引用
收藏
页数:116
相关论文
共 50 条
  • [41] A novel method to estimate the dead layer of HPGe detector for Monte Carlo FEPE computation
    Satti, Khizar Hayat
    Siddique, Muhammad Tariq
    Dilband, Muhammad
    Rehman, Shakeel Ur
    Mansoor, Shahid
    Malik, Azhar Hussain
    APPLIED RADIATION AND ISOTOPES, 2023, 202
  • [42] Calculating off-axis efficiency of coaxial HPGe detectors by Monte Carlo simulation
    Omer, Mohamed
    Shizuma, Toshiyuki
    Hajima, Ryoichi
    Koizumi, Mitsuo
    Radiation Physics and Chemistry, 2022, 198
  • [43] Calculating off-axis efficiency of coaxial HPGe detectors by Monte Carlo simulation
    Omer, Mohamed
    Shizuma, Toshiyuki
    Hajima, Ryoichi
    Koizumi, Mitsuo
    RADIATION PHYSICS AND CHEMISTRY, 2022, 198
  • [44] Monte Carlo simulation of an HPGe detector for detection of 239Pu in waste assay system
    Narayanam, Sujatha Pavan
    Manohari, M.
    Ramar, R.
    Subramanian, V
    Mathiyarasu, R.
    Srinivas, C., V
    Baskaran, R.
    APPLIED RADIATION AND ISOTOPES, 2019, 152 : 127 - 134
  • [45] Evaluation of concepts of fin efficiency using Monte Carlo Simulation method
    Maheswaran, U
    Sekhar, SC
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (9-10) : 1643 - 1646
  • [46] Using Monte Carlo Simulations and Experimental Measurements to Calibrate An HPGE Gamma Detector Precisely
    Zhai, Yongjun
    Trache, Livius
    Tribble, Robert
    Papanikolaou, Nikos
    Liu, Yaxi
    Shi, Chengyu
    Iacob, Victor
    Hardy, John
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2009, 32 (01): : 105 - 106
  • [47] Monte Carlo calculation of the efficiency response of a low-background well-type HPGe detector
    Laborie, JM
    Le Petit, G
    Abt, D
    Girard, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3): : 618 - 630
  • [48] The effect of two-part dead layer thickness on the efficiency curve of a P-TYPE HPGe detector calculated using the Monte Carlo method
    Aksoy, Gulper
    Unlu, Hasan
    Orhan, Nilguen
    Yuksel, Ayhan
    Bolukdemir, Mustafa Hicabi
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [49] Application of unfolding technique to HPGe detector using response functions calculated with the EGS4 Monte Carlo code
    Chun, KJ
    Hah, SH
    Kim, HM
    Yoo, GH
    JOURNAL OF RADIATION RESEARCH, 2006, 47 (01) : 27 - 40
  • [50] STUDY ON VARIATION OF HPGE DETECTOR DEAD LAYER THICKNESS AND ITS EFFECT ON THE MEASUREMENTS OF THE DETECTOR RESPONSE AND SAMPLES CHARACTERIZATION USING MONTE CARLO SIMULATION
    Abd El Gawad, K.
    Song, Yushou
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 3, 2018,