Efficiency Application of Monte Carlo Simulation and HPGe Detector Using Mapping Method

被引:0
|
作者
Jang, Eun-Sung [1 ]
Chang, Bo-Seok [2 ]
机构
[1] Kosin Univ, Gospel Hosp, Dept Radiat Oncol, Busan 49267, South Korea
[2] Kaya Univ, Depart Radiol Sci, Gimhae 50830, South Korea
关键词
mapping; monte carlo simulation; Computed Tomography (CT); HPGe detector; electromagnetic X-ray image; CALIBRATION;
D O I
10.4283/JMAG.2024.29.2.172
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to obtain the detection efficiency according to the distance around the detector, the total energy peak efficiency was used, and the grid mapping method was used to investigate axis-symmetry. The detector was measured at 0.5 cm intervals up to 5 cm in the x, z, direction, and 5.5 cm in the y direction. The efficiency of the cylinder beaker and marinelli beakers at the center of the 134Cs 604 keV detector was compared with the efficiency of the mapping method. For cylinder beakers, the efficiency was 0.0412 +/- 0.002, and the efficiency by mapping was 0.040 +/- 0.001, which was consistent within 3 % of the uncertainty range. For Marinelli beakers, the efficiency was 0.0242 +/- 0.002 mapping efficiency was 0.0248 +/- 0.0013. It was confirmed that precise measurement of radioactive sources with volume was possible when measured at each point around the detector.
引用
收藏
页数:116
相关论文
共 50 条
  • [31] Full energy peak efficiency calibration of HPGe detector for point and extended sources using Monte Carlo code
    Chhavi Agarwal
    Sanhita Chaudhury
    A. Goswami
    M. Gathibandhe
    Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 701 - 708
  • [32] Full energy peak efficiency calibration of HPGe detector for point and extended sources using Monte Carlo code
    Agarwal, Chhavi
    Chaudhury, Sanhita
    Goswami, A.
    Gathibandhe, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (03) : 701 - 708
  • [33] Characterizing the coaxial HPGe detector using Monte Carlo simulations and evolutionary algorithms
    Prozorova, Irina, V
    Ghal-Eh, Nima
    Bedenko, Sergey, V
    Popov, Yury A.
    Prozorov, Andrey A.
    Vega-Carrillo, Hector R.
    APPLIED RADIATION AND ISOTOPES, 2021, 174
  • [34] Estimation of background spectrum in a shielded HPGe detector using Monte Carlo simulations
    Medhat, M. E.
    Wang, Yifang
    APPLIED RADIATION AND ISOTOPES, 2014, 84 : 13 - 18
  • [35] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    Penabei, S.
    Bongue, D.
    Mistura, A. B.
    Maleka, P.
    Demdah, K. M.
    Kwato, G. N. M.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2024, 21 (04) : 4509 - 4518
  • [36] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    S. Penabeï
    D. Bongue
    A. B. Mistura
    P. Maleka
    K. M. Demdah
    G. N. M. Kwato
    International Journal of Environmental Science and Technology, 2024, 21 : 4509 - 4518
  • [37] Monte-Carlo calculation of the spatial dependence of the coaxial HPGe detector efficiency for point sources
    Korun, M
    Likar, A
    Vidmar, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 390 (1-2): : 203 - 208
  • [38] Monte Carlo based geometrical model for efficiency calculation of an n-type HPGe detector
    Padilla Cabal, Fatima
    Lopez-Pino, Neivy
    Luis Bernal-Castillo, Jose
    Martinez-Palenzuela, Yisel
    Aguilar-Mena, Jimmy
    D'Alessandro, Katia
    Arbelo, Yuniesky
    Corrales, Yasser
    Diaz, Oscar
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (12) : 2403 - 2408
  • [39] Precise efficiency calibration of an HPGe detector up to 3.5 MeV, with measurements and Monte Carlo calculations
    Helmer, RG
    Nica, N
    Hardy, JC
    Iacob, VE
    APPLIED RADIATION AND ISOTOPES, 2004, 60 (2-4) : 173 - 177
  • [40] Monte Carlo calculations of the HPGe detector efficiency for radioactivity measurement of large volume environmental samples
    Azbouche, Ahmed
    Belgaid, Mohamed
    Mazrou, Hakim
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 146 : 119 - 124