Molded Round Window Niche Implant as a Dexamethasone Delivery System in a Cochlear Implant-Trauma Animal Model

被引:1
|
作者
Wei, Chunjiang [1 ,2 ,3 ]
Gao, Ziwen [1 ,2 ,4 ,5 ]
Mau, Robert [6 ]
Eickner, Thomas [7 ]
Juettner, Gabor [8 ]
Fiedler, Nicklas [7 ]
Seitz, Hermann [6 ,9 ]
Lenarz, Thomas [1 ,2 ,3 ]
Scheper, Verena [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Hannover Med Sch, German Res Fdn DFG Forsch Gemeinschaft, Cluster Excellence Hearing4all, Carl Neuberg Str 1, D-30625 Hannover, Germany
[3] Lower Saxony Ctr Biomed Engn Implant Res & Dev NIF, Stadtfelddamm 34, D-30625 Hannover, Germany
[4] Fudan Univ, Eye & ENT Hosp, ENT Inst, Shanghai 200031, Peoples R China
[5] Fudan Univ, Eye & ENT Hosp, Dept Otorhinolaryngol, Shanghai 200031, Peoples R China
[6] Univ Rostock, Fac Mech Engn & Marine Technol, Microfluid, Justus von Liebig Weg 6, D-18059 Rostock, Germany
[7] Univ Rostock, Univ Med Ctr Rostock, Inst Biomed Engn, Friedrich Barnewitz Str 4, D-18119 Rostock, Germany
[8] Kunststoff Zentrum Leipzig gGmbH, Erich Zeigner Allee 44, D-04229 Leipzig, Germany
[9] Univ Rostock, Interdisciplinary Fac, Dept Life Light & Matter, Albert Einstein Str 25, D-18059 Rostock, Germany
关键词
local inner ear drug therapy; round window niche implant; cochlear implant surgery; dexamethasone; guinea pig; local pharmacotherapy; AUDITORY HAIR-CELLS; ALPHA-INDUCED LOSS; GUINEA-PIG MODEL; INNER-EAR; DRUG-DELIVERY; RESIDUAL HEARING; SCALA TYMPANI; PRESERVATION; ELECTRODES; IMPEDANCE;
D O I
10.3390/pharmaceutics16091236
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (mu CT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Deep round window insertion versus standard approach in cochlear implant surgery
    Nordfalk, Karl Fredrik
    Rasmussen, Kjell
    Bunne, Marie
    Jablonski, Greg Eigner
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (01) : 43 - 50
  • [22] Dexamethasone delivery for hearing preservation in animal cochlear implant model: continuity, long-term release, and fast release rate
    Lee, Min Young
    Kim, Young Cheol
    Jang, Jongmoon
    Jung, Jae Yun
    Choi, Hongsoo
    Jang, Jeong Hun
    Choung, Yun-Hoon
    ACTA OTO-LARYNGOLOGICA, 2020, 140 (09) : 713 - 722
  • [23] The Value of Endoscopic Exposure of Round Window in Cochlear Implant via Facial Recess
    Nassif, Mena Maher
    Darahem, Islam Mohamed Hussein
    Teaima, Ahmed Abdelmoneim
    Mustafa, Mustafa Mohamed
    Allah, Mohamed Saad Hassab
    Ibrahim, Samer Ahmed
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2024, 28 (01) : E107 - E114
  • [24] Preoperative and Intraoperative Evaluation of Round Window Configuration during Cochlear Implant in Children
    Singh, Jyoti
    Prakash, Jayant
    Mishra, Sarita Kumari
    Jha, Shruti
    Singh, Rakesh Kumar
    INDIAN JOURNAL OF OTOLOGY, 2022, 28 (02) : 135 - 138
  • [25] Cochlear implantation in an animal model documents cochlear damage at the tip of the implant
    Cruz de Andrade, Jose Santos
    Baumhoff, Peter
    Mendonca Cruz, Oswaldo Laercio
    Lenarz, Thomas
    Kral, Andrej
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2022, 88 (04) : 546 - 555
  • [26] Experimental investigations on the coupling of an active middle ear implant on the round and oval window niche
    Zahnert, Thomas
    Lasurashvili, Nikoloz
    Bornitz, Matthias
    Huettenbrink, Karl-Bernd
    HEARING RESEARCH, 2010, 263 (1-2) : 238 - 238
  • [27] COCHLEAR IMPLANT ROUND WINDOW SEALING PROCEDURES IN THE CAT - AN INVESTIGATION OF AUTOGRAFT AND HETEROGRAFT MATERIALS
    CLARK, GM
    SHEPHERD, RK
    ACTA OTO-LARYNGOLOGICA, 1984, : 5 - 15
  • [28] Histological Reaction in the Round Window Membrane after Cochlear Implant Insertion in Nonhuman Primates
    Picciafuoco, Sebastian
    Manrique-Huarte, Raquel
    De Abajo, Jorge
    de Linera-Alperi, Marta Alvarez
    Gallego, Maria Antonia
    Manrique, Manuel
    AUDIOLOGY AND NEUROTOLOGY, 2024, 29 (03) : 181 - 192
  • [29] Intraoperative Round Window Electrocochleography and Speech Perception Outcomes in Pediatric Cochlear Implant Recipients
    Formeister, Eric J.
    McClellan, Joseph H.
    Merwin, William H., III
    Iseli, Claire E.
    Calloway, Nathan H.
    Teagle, Holly F. B.
    Buchman, Craig A.
    Adunka, Oliver F.
    Fitzpatrick, Douglas C.
    EAR AND HEARING, 2015, 36 (02): : 249 - 260
  • [30] PROGNOSTIC VALUE OF ROUND-WINDOW PSYCHOPHYSICAL TESTING WITH COCHLEAR-IMPLANT CANDIDATES
    SHIPP, DB
    NEDZELSKI, JM
    JOURNAL OF OTOLARYNGOLOGY, 1994, 23 (03): : 172 - 176