Molded Round Window Niche Implant as a Dexamethasone Delivery System in a Cochlear Implant-Trauma Animal Model

被引:1
|
作者
Wei, Chunjiang [1 ,2 ,3 ]
Gao, Ziwen [1 ,2 ,4 ,5 ]
Mau, Robert [6 ]
Eickner, Thomas [7 ]
Juettner, Gabor [8 ]
Fiedler, Nicklas [7 ]
Seitz, Hermann [6 ,9 ]
Lenarz, Thomas [1 ,2 ,3 ]
Scheper, Verena [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Hannover Med Sch, German Res Fdn DFG Forsch Gemeinschaft, Cluster Excellence Hearing4all, Carl Neuberg Str 1, D-30625 Hannover, Germany
[3] Lower Saxony Ctr Biomed Engn Implant Res & Dev NIF, Stadtfelddamm 34, D-30625 Hannover, Germany
[4] Fudan Univ, Eye & ENT Hosp, ENT Inst, Shanghai 200031, Peoples R China
[5] Fudan Univ, Eye & ENT Hosp, Dept Otorhinolaryngol, Shanghai 200031, Peoples R China
[6] Univ Rostock, Fac Mech Engn & Marine Technol, Microfluid, Justus von Liebig Weg 6, D-18059 Rostock, Germany
[7] Univ Rostock, Univ Med Ctr Rostock, Inst Biomed Engn, Friedrich Barnewitz Str 4, D-18119 Rostock, Germany
[8] Kunststoff Zentrum Leipzig gGmbH, Erich Zeigner Allee 44, D-04229 Leipzig, Germany
[9] Univ Rostock, Interdisciplinary Fac, Dept Life Light & Matter, Albert Einstein Str 25, D-18059 Rostock, Germany
关键词
local inner ear drug therapy; round window niche implant; cochlear implant surgery; dexamethasone; guinea pig; local pharmacotherapy; AUDITORY HAIR-CELLS; ALPHA-INDUCED LOSS; GUINEA-PIG MODEL; INNER-EAR; DRUG-DELIVERY; RESIDUAL HEARING; SCALA TYMPANI; PRESERVATION; ELECTRODES; IMPEDANCE;
D O I
10.3390/pharmaceutics16091236
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (mu CT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] A Study of Round Window and its Adjacent Anatomy to Guide the Cochlear Implant Electrode Insertion
    Kataria, Tanmaya
    Sharma, Shitanshu
    Lakhawat, Rajendra Singh
    Grover, Mohnish
    Sharma, Shivam
    Kanodia, Anupam
    Agarwal, Srishti
    Samdani, Sunil
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2023, 75 (SUPPL 1) : 163 - 169
  • [32] A Study of Round Window and its Adjacent Anatomy to Guide the Cochlear Implant Electrode Insertion
    Tanmaya Kataria
    Shitanshu Sharma
    Rajendra Singh Lakhawat
    Mohnish Grover
    Shivam Sharma
    Anupam Kanodia
    Srishti Agarwal
    Sunil Samdani
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2023, 75 : 163 - 169
  • [33] Tinnitus Suppression with Electrical Stimulation at the Most Basal Contact of the Cochlear Implant Electrode as a Model for Round Window Stimulation
    Kheirkhah, Kiana
    Van Kelecom, Valerie
    Leblans, Marc
    van Dinther, Joost
    De Greve, Glynnis
    Offeciers, Erwin
    Zarowski, Andrzej
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2024, 20 (05):
  • [34] The Miniature Pig: A Large Animal Model for Cochlear Implant Research
    Ji, Xiaojun
    Luo, Yi
    Guo, Weiwei
    Ji, Fei
    Yuan, Shuolong
    Xu, Liangwei
    Chen, Wei
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (185):
  • [35] A Micro-computed Study of Round Window Anatomy and Implications for Atraumatic Cochlear Implant Insertion
    Cornwall, Hannah Louisa
    Marway, Prabhvir Singh
    Bance, Manohar
    OTOLOGY & NEUROTOLOGY, 2021, 42 (02) : 327 - 334
  • [36] ORIENTATION FOR COCHLEAR IMPLANT-SURGERY IN CASES WITH ROUND WINDOW OBSTRUCTION - A COMPUTER RECONSTRUCTION STUDY
    TAKAHASHI, H
    HONJO, I
    SANDO, I
    TAKAGI, A
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1995, 252 (02) : 102 - 105
  • [37] Comparison of Cochlear Implant Performance after Round Window Electrode Insertion Compared with Traditional Cochleostomy
    Kang, Bryan J.
    Kim, Ana H.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2013, 148 (05) : 822 - 826
  • [38] Combined preoperative HRCT parameters for prediction of round window visibility in pediatric cochlear implant patient
    Ghoneim, Mahitab Mohamed Rashad
    Ghonim, Mohamed Rashad
    Badawy, Ahmed Ali Mohamed
    Razek, Ahmed Abdel Khalek Abdel
    Hafez, Montaser Abdel Salam
    Hamad, Mostafa Sayed
    Salem, Mohammed Abdelbadie
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2021, 140
  • [39] Alteration of the relative vibration of the round window membrane after implantation of a direct acoustic cochlear implant
    D'hondt, Christiane
    Wouters, Jan
    Verhaert, Nicolas
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2020, 59 (05) : 341 - 347
  • [40] A COMPARISON OF ROUND-WINDOW AND TRANSTYMPANIC PROMONTORY ELECTRIC-STIMULATION IN COCHLEAR IMPLANT CANDIDATES
    KILENY, PR
    ZWOLAN, TA
    ZIMMERMANPHILLIPS, S
    KEMINK, JL