Molded Round Window Niche Implant as a Dexamethasone Delivery System in a Cochlear Implant-Trauma Animal Model

被引:1
|
作者
Wei, Chunjiang [1 ,2 ,3 ]
Gao, Ziwen [1 ,2 ,4 ,5 ]
Mau, Robert [6 ]
Eickner, Thomas [7 ]
Juettner, Gabor [8 ]
Fiedler, Nicklas [7 ]
Seitz, Hermann [6 ,9 ]
Lenarz, Thomas [1 ,2 ,3 ]
Scheper, Verena [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Otolaryngol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Hannover Med Sch, German Res Fdn DFG Forsch Gemeinschaft, Cluster Excellence Hearing4all, Carl Neuberg Str 1, D-30625 Hannover, Germany
[3] Lower Saxony Ctr Biomed Engn Implant Res & Dev NIF, Stadtfelddamm 34, D-30625 Hannover, Germany
[4] Fudan Univ, Eye & ENT Hosp, ENT Inst, Shanghai 200031, Peoples R China
[5] Fudan Univ, Eye & ENT Hosp, Dept Otorhinolaryngol, Shanghai 200031, Peoples R China
[6] Univ Rostock, Fac Mech Engn & Marine Technol, Microfluid, Justus von Liebig Weg 6, D-18059 Rostock, Germany
[7] Univ Rostock, Univ Med Ctr Rostock, Inst Biomed Engn, Friedrich Barnewitz Str 4, D-18119 Rostock, Germany
[8] Kunststoff Zentrum Leipzig gGmbH, Erich Zeigner Allee 44, D-04229 Leipzig, Germany
[9] Univ Rostock, Interdisciplinary Fac, Dept Life Light & Matter, Albert Einstein Str 25, D-18059 Rostock, Germany
关键词
local inner ear drug therapy; round window niche implant; cochlear implant surgery; dexamethasone; guinea pig; local pharmacotherapy; AUDITORY HAIR-CELLS; ALPHA-INDUCED LOSS; GUINEA-PIG MODEL; INNER-EAR; DRUG-DELIVERY; RESIDUAL HEARING; SCALA TYMPANI; PRESERVATION; ELECTRODES; IMPEDANCE;
D O I
10.3390/pharmaceutics16091236
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background: Preserving residual hearing after cochlear implant (CI) surgery remains a crucial challenge. The application of dexamethasone (DEX) has been proven to positively affect residual hearing. To deliver DEX in a localized and controlled way, a round window niche implant (RNI), allowing drug diffusion via the round window membrane into the cochlea, may be used. To prove this concept, an RNI for guinea pigs as a CI-trauma model was manufactured by molding and tested for its drug release in vitro and biological effects in vivo. Methods: The RNIs were molded using silicone containing 10% DEX. Release was analyzed over time using high-performance liquid chromatography (HPLC). Fourteen adult guinea pigs were randomly assigned to two groups (CI or CI + RNI group). All animals received a unilateral CI electrode insertion trauma followed by CI insertion. The CI + RNI group was additionally implanted with an RNI containing 10% DEX. Animals were followed up for 4 weeks. Acoustically evoked auditory brainstem response and impedance measurement, micro-computed tomography (mu CT) imaging, and histology were performed for evaluation. Results: DEX was released for more than 250 days in vitro, with an initial burst followed by a slower release over time. Comparing the hearing threshold shift (from day 0 to day 28) of the CI and CI + RNI groups, significant differences were observed at 32 and 40 kHz. The impedance shift at basal contacts was lower in the CI + RNI group than in the CI group. Moreover, the fibrosis in the lower basal turn was reduced in the CI + RNI group in contrast to the CI group. Conclusions: The RNI containing 10% DEX has anti-inflammatory potential concerning fibrosis inhibition and has beneficial effects on hearing preservation at high frequencies.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Dexamethasone Delivery by an Implant-Mediated Drug Delivery System in the Canine Mandible
    Park, Jae-Hwan
    Cha, Hyun-Suk
    Kim, Hong-Kyun
    Park, Young-Seok
    JOURNAL OF PERIODONTOLOGY, 2016, 87 (06) : 700 - 705
  • [42] A full-custom fully implantable cochlear implant system validated in vivo with an animal model
    Hasan Uluşan
    M. Berat Yüksel
    Özlem Topçu
    H. Andaç Yiğit
    Akın M. Yılmaz
    Mert Doğan
    Nagihan Gülhan Yasar
    İbrahim Kuyumcu
    Aykan Batu
    Nebil Göksu
    M. Birol Uğur
    Haluk Külah
    Communications Engineering, 3 (1):
  • [43] Meriones unguiculatus (Gerbil) as an animal model for the ontogenetic cochlear implant research
    Hessel, H
    Ernst, LS
    Walger, M
    vonWedel, H
    Dybek, A
    Schmidt, U
    AMERICAN JOURNAL OF OTOLOGY, 1997, 18 (06): : S21 - S21
  • [44] Effects of round window dexamethasone on residual hearing in a guinea pig model of cochlear implantation
    James, David P.
    Eastwood, Hayden
    Richardson, Rachael T.
    O'Leary, Stephen J.
    AUDIOLOGY AND NEURO-OTOLOGY, 2008, 13 (02) : 86 - 96
  • [45] Effectiveness of Dexamethasone Intravitreal Implant in an Animal Model of Chronic Retinal Neovascularization
    Li, Y.
    Burke, J. A.
    Vilupuru, A. S.
    Tsai, S.
    Lin, T.
    Ghosn, C.
    Whitcup, S. M.
    Wheeler, L. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [46] Cochlear implantation via round window or cochleostomy: Effect on hearing in an animal model
    Hod, Roy
    Attias, Joseph
    Raveh, Eyal
    Nageris, Ben I.
    LARYNGOSCOPE, 2016, 126 (11): : E375 - E378
  • [47] Role of HRCT imaging in predicting the visibility of Round window (RW) on patients underwent cochlear implant surgery
    Sarafraz, Mozafar
    Heidari, Mahsa
    Bayat, Arash
    Hanafi, Mohammad Ghasem
    Fahimi, Ali
    Farasat, Maryam
    Saki, Nader
    Molaei, Javad
    CLINICAL EPIDEMIOLOGY AND GLOBAL HEALTH, 2020, 8 (02): : 432 - 436
  • [48] Cochlear implant explantation: An in vitro model to evaluate electrode explant force and trauma
    Asfour, Leena
    Risi, Frank
    Miah, Hanif
    Roland, J. Thomas, Jr.
    COCHLEAR IMPLANTS INTERNATIONAL, 2022, 23 (04) : 189 - 194
  • [49] Round window application of an active middle ear implant (AMEI) system in congenital oval window atresia
    Zhao, Shouqin
    Gong, Shusheng
    Han, Demin
    Zhang, Hua
    Ma, Xiaobo
    Li, Yi
    Chen, Xueqing
    Ren, Ran
    Li, Yuling
    ACTA OTO-LARYNGOLOGICA, 2016, 136 (01) : 23 - 33
  • [50] An Evaluation of the Surgical Trauma to Intracochlear Structures After Insertion of Cochlear Implant Electrode Arrays: A Comparison by Round Window and Antero-Inferior Cochleostomy Techniques
    Sikka K.
    Kairo A.
    Singh C.A.
    Roy T.S.
    Lalwani S.
    Kumar R.
    Thakar A.
    Sharma S.C.
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2017, 69 (3) : 375 - 379