Histological Reaction in the Round Window Membrane after Cochlear Implant Insertion in Nonhuman Primates

被引:0
|
作者
Picciafuoco, Sebastian [1 ]
Manrique-Huarte, Raquel [1 ]
De Abajo, Jorge [1 ]
de Linera-Alperi, Marta Alvarez [1 ]
Gallego, Maria Antonia [1 ]
Manrique, Manuel [1 ]
机构
[1] Univ Clin Navarra, Otorhinolaryngol Dept, Pamplona, Spain
关键词
Cochlear implants; Round window; Inner ear; Residual hearing; Hearing preservation; HEARING-LOSS; SURGICAL ANATOMY; TEMPORAL BONE; HISTOPATHOLOGY; ELECTRODES; SURGERY; MODEL; PRESERVATION; PATHOLOGY; REVISION;
D O I
10.1159/000533194
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: The primary objective of this article was to determine if any histological alterations occur in the round window (RW) and adjacent anatomical structures of an animal model with normal hearing when a cochlear implant (CI) electrode array is inserted. Furthermore, this article aims to relate these histological alterations to the auditory changes generated. Methods: Cochlear implantation was performed, following the principles of minimally traumatic surgery (MTS), in 15 ears of nonhuman primates (Macaca fascicularis) (Mf) with normal hearing. Auditory brainstem-evoked potentials (ABR) using clicks and tones were used prior to surgery and during a 6-month follow-up period. Histological evaluation was carried out, analyzing the position of the electrode array with respect to the round window membrane (RWM), its percentage of occupation and integrity, the presence of intracochlear damage, and the tissue reaction provoked, the latter of which was quantified in the temporal bones. Results: Surgery was performed on all 15 ears without relevant incidences. Regarding histology, the electrode array in the RW of all ears presented a lateral position with respect to the modiolus. No lesions affecting the integrity of the RW were observed. The mean value of the array's occupation in the RW was 25%. Tissue reaction, in the form of fibrosis, was observed in all ears and more intensely in the trans-RWM and post-RWM areas. In all ears, the electrodes remained on the scala tympani. No profound hearing impairment was recorded in any ear, being the mean loss of 25.4 dB when comparing presurgical thresholds with those collected 6 months after implantation in ABR click and 24.4 dB in ABR tone burst. Conclusions: The animal model and Hybrid L-14 (HL14) electrode array were optimal for implementing a surgical technique similar to that routinely performed on humans. Mild histological alterations were observed in the round window membrane and adjacent anatomical structures from the insertion of a cochlear implant electrode array. Following the minimally invasive technique, levels of hearing preservation were satisfactory, reaching a pre-post difference of 25.4 dB in the ABR click and 24.4 dB for a high-frequency tone burst. Complete hearing impairment was not observed in either ear. Correlation between the severity of histological alterations and hearing changes recorded in the ABR studies was observed.
引用
收藏
页码:181 / 192
页数:12
相关论文
共 50 条
  • [1] Round Window Membrane Insertion With Perimodiolar Cochlear Implant Electrodes
    Coordes, Annekatrin
    Ernst, Arne
    Brademann, Goetz
    Todt, Ingo
    OTOLOGY & NEUROTOLOGY, 2013, 34 (06) : 1027 - 1032
  • [2] Round window electrocochleography before and after cochlear implant electrode insertion
    Adunka, Oliver F.
    Giardina, Christopher K.
    Formeister, Eric J.
    Choudhury, Baishakhi
    Buchman, Craig A.
    Fitzpatrick, Douglas C.
    LARYNGOSCOPE, 2016, 126 (05): : 1193 - 1200
  • [3] Evaluation of round window accessibility to cochlear implant insertion
    Annabelle C. Leong
    Dan Jiang
    Andreas Agger
    Alec Fitzgerald-O’Connor
    European Archives of Oto-Rhino-Laryngology, 2013, 270 : 1237 - 1242
  • [4] Evaluation of round window accessibility to cochlear implant insertion
    Leong, Annabelle C.
    Jiang, Dan
    Agger, Andreas
    Fitzgerald-O'Connor, Alec
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2013, 270 (04) : 1237 - 1242
  • [5] Cochlear implant electrode insertion: The round window revisited
    Roland, Peter S.
    Wright, Charles G.
    Isaacson, Brandon
    LARYNGOSCOPE, 2007, 117 (08): : 1397 - 1402
  • [6] Comparison of Cochlear Implant Performance after Round Window Electrode Insertion Compared with Traditional Cochleostomy
    Kang, Bryan J.
    Kim, Ana H.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2013, 148 (05) : 822 - 826
  • [7] Deep round window insertion versus standard approach in cochlear implant surgery
    Karl Fredrik Nordfalk
    Kjell Rasmussen
    Marie Bunne
    Greg Eigner Jablonski
    European Archives of Oto-Rhino-Laryngology, 2016, 273 : 43 - 50
  • [8] Deep round window insertion versus standard approach in cochlear implant surgery
    Nordfalk, Karl Fredrik
    Rasmussen, Kjell
    Bunne, Marie
    Jablonski, Greg Eigner
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2016, 273 (01) : 43 - 50
  • [9] Round Window Membrane Visibility and its Implications in Cochlear Implant Surgery
    Tadke, Kanchan
    Girde, Harshali
    Bhosey, Labhashree
    Daund, Aniket
    Musty, Sai
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2024, : 342 - 348
  • [10] Alteration of the relative vibration of the round window membrane after implantation of a direct acoustic cochlear implant
    D'hondt, Christiane
    Wouters, Jan
    Verhaert, Nicolas
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2020, 59 (05) : 341 - 347