Co-flow jets application for occupant targeted ventilation: Focus on thermal comfort and air quality

被引:1
|
作者
Zhou, Bin [1 ]
Li, Zhe [2 ]
Yang, Bin [2 ]
Wang, Faming [3 ]
Ai, Zhengtao [4 ]
Melikov, Arsen [5 ]
机构
[1] Xian Univ Architecture & Technol, Sch Bldg Serv Sci & Engn, Xian 710055, Peoples R China
[2] Tianjin Chengjian Univ, Sch Energy & Safety Engn, Tianjin 300384, Peoples R China
[3] Katholieke Univ Leuven, Dept Biosyst, B-3001 Leuven, Belgium
[4] Hunan Univ, Coll Civil Engn, Dept Bldg Environm & Energy, Changsha 410082, Peoples R China
[5] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, Dept Civil Engn, DK-2800 Lyngby, Denmark
关键词
Occupant targeted ventilation; Co-flow jet velocity; Turbulence intensity; Equivalent frequency; Air quality; Abbreviations; Nomenclature; PERSONALIZED VENTILATION; PERFORMANCE; SYSTEM; HOT;
D O I
10.1016/j.buildenv.2024.112086
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Co-flow air jets can be used in occupant-targeted ventilation, such as personalized ventilation, stratum ventilation, aiming at improving air quality in the breathing zone of occupants. However, these have not been studied sufficiently. The velocity field and cleanness of co-flow jets comprising inner jet of clean air encircled by outer jet of room air were studied under isothermal conditions by physical measurements and CFD simulations at numerous combinations of initial diameter and velocity of the inner and outer jets appropriate for practical application. The co-flow jet had a lower axial velocity decay along the jet direction than that of the single jet. The magnitude (turbulence intensity) and frequency of the velocity fluctuations in co-flow jets were lower compared to those in a single jet. The results revealed that with regard to thermal comfort co-flow jets may provide more cooling compared to single jets, especially when supplied toward to the user. The level of cleanness depended on the initial velocity of the inner and outer jets as well as their diameters. The air on the jet axis of the co-flow was up to 40 % cleaner compared to the single jet. The increased area ratio of outer nozzle to inner nozzle from 1.0 to 3.0 improved the cleanness of the air by at least 10% to the distance from 8 to 14 initial diameters compared to a single jet. The co-flow jet with velocity ratio of 1.5 had longest concentration core length, Lu, (up to 6 initial diameters to the inner jet) with clean air. The results can be used for design of occupant targeted ventilation.
引用
收藏
页数:24
相关论文
共 50 条
  • [21] Indoor air quality, thermal comfort and ventilation in deep energy retrofitted Irish dwellings
    Coggins, Ann Marie
    Wemken, Nina
    Mishra, Asit Kumar
    Sharkey, Martin
    Horgan, Liam
    Cowie, Hilary
    Bourdin, Emmanuel
    McIntyre, Brian
    BUILDING AND ENVIRONMENT, 2022, 219
  • [22] Impact of impinging jet ventilation on thermal comfort and indoor air quality in office buildings
    Staveckis, Arturs
    Borodinecs, Anatolijs
    ENERGY AND BUILDINGS, 2021, 235
  • [23] A review of different ventilation modes on thermal comfort, air quality and virus spread control
    Fan, Man
    Fu, Zheng
    Wang, Jia
    Wang, Zhaoying
    Suo, Hanxiao
    Kong, Xiangfei
    Li, Han
    BUILDING AND ENVIRONMENT, 2022, 212
  • [24] Assessment of Thermal Comfort and Air Quality of Room Conditions by Impinging Jet Ventilation Integrated with Ductless Personalized Ventilation
    Yang, Bin
    Liu, Pengju
    Liu, Yihang
    Jin, Dacheng
    Wang, Faming
    SUSTAINABILITY, 2022, 14 (19)
  • [25] Associations of occupant demographics, thermal history and obesity variables with their thermal comfort in air-conditioned and mixed-mode ventilation office buildings
    Rupp, Ricardo Forgiarini
    Kim, Jungsoo
    de Dear, Richard
    Ghisi, Enedir
    BUILDING AND ENVIRONMENT, 2018, 135 : 1 - 9
  • [26] Thermal comfort and indoor air quality in low-income housing in Spain: The influence of airtightness and occupant behaviour
    Fernandez-Aguera, Jesica
    Dominguez-Amarillo, Samuel
    Alonso, Carmen
    Martin-Consuegra, Fernando
    ENERGY AND BUILDINGS, 2019, 199 : 102 - 114
  • [27] Numerical Comparison of Thermal Comfort and Air Age Between Two Combined Ventilation Systems with Chilled Ceiling Considering Occupant Density
    Nayyef, Dhuha Radhi
    Mahdi, Ala'a Abbas
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (01) : 213 - 223
  • [28] Natural ventilation in warm climates: The challenges of thermal comfort, heatwave resilience and indoor air quality
    Ahmed, Tariq
    Kumar, Prashant
    Mottet, Laetitia
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 138
  • [29] Combining chilled ceiling, displacement ventilation and desiccant dehumidification for indoor air quality and thermal comfort
    Hao, XL
    Zhang, GQ
    Chen, YM
    Zou, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1248 - 1253
  • [30] Effect of sinusoidal splitter on mixing performance of co-flow jets of hydrogen and air inside dual-combustor ramjet
    Sun, Chuan
    Rayeni, Nima Sharifi
    Moghimihanjani, Mehrafarin
    Moradi, R.
    Li, Zhixiong
    ACTA ASTRONAUTICA, 2021, 180 : 211 - 217